Description
1. Commercial Introduction
The polypropylene suture Premisut that Cahnos makes available to surgical services, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a 16 mm reverse cutting triangular point (DS16 profile), USP 4/0 gauge and a 75 cm strand in high-visibility blue: a fine, precise configuration widely used in superficial planes, delicate tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
The product is supplied sterile, ready for single use and with batch traceability, which facilitates hospital stock management and submission to public tenders. It is supplied in a box of 12 units under the factory reference 732DS1640 (SKU Cahnos AM732DS1640), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) extruded as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS16 needle of ⅜ circle and reverse cutting triangular point places the cutting edge on the outer face of the curve, allowing it to pass through firm, non-distensible tissues (skin, fascia, subcutaneous) with a clean, stable cut, reducing the risk of tearing and allowing controlled passage even in areas of limited access or microsurgery. The blue colour of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Main features: uncoated blue-dyed polypropylene monofilament; 16 mm DS16 needle with reverse cutting triangular point; USP 4/0 gauge; 75 cm thread; EO sterilisation; presentation in a box of 12 units.
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut (standard quality, DS16 needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.150 – 0.199 mm (according to USP, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, DS profile |
| Needle size | 16 mm (DS16 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732DS1640 |
| Reference Cahnos (SKU) | AM732DS1640 |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 | 1.5 | 0.150 – 0.199 mm (non-absorbable suture) |
4. Equivalences and Cross-References
Reference 732DS1640 corresponds to the official nomenclature of the Premisut range (DS16 profile, reverse cutting triangular point, standard quality) and is marketed by Cahnos keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Consult the Cahnos technical department to validate any equivalence before use.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut) | Polypropylene DS16, USP 4/0, blue, 75 cm (standard quality) | 732DS1640 / AM732DS1640 | Direct product reference | Product analysed in this data sheet |
| Cahnos (Premisut Prime) | Polypropylene DS16 Prime, USP 4/0, blue, 75 cm | P732DS1640 / AMP732DS1640 | Direct range equivalent | Same needle, gauge, colour and length; Prime quality (premium grooved needle) versus standard |
| Cahnos (Premisut) | Polypropylene DS16, USP 3/0, blue, 75 cm | 732DS1630 / AM732DS1630 | Comparable within the system | Same DS16 needle and colour; 3/0 gauge with larger diameter for greater mechanical demand |
| Cahnos (Premisut) | Polypropylene DS16, USP 6/0, blue, 75 cm | 732DS1660 / AM732DS1660 | Comparable within the system | Same DS16 needle; 6/0 gauge for microsurgery of maximum fineness |
| Cahnos (Premisut) | Polypropylene DS19, USP 4/0, blue, 75 cm | 732DS1940 / AM732DS1940 | Comparable within the system | Same gauge and colour; DS19 needle of 19 mm versus DS16 |
| Cahnos (Premisut) | Polypropylene DS19, USP 4/0, blue, 45 cm | 731DS1940 / AM731DS1940 | Comparable within the system | Same needle (DS19) and gauge; 45 cm thread in compact presentation |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 4/0 | 8699G / 8682G / 8683G (depending on P-3, PS-2 or FS-2 needle profile) | Comparable by category, not interchangeable 1:1 | Codes verified in authorised distribution for 4/0 gauge; material, gauge and colour match, but the geometry and needle size of the PROLENE series differ from the DS16. Confirm CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 4/0 (1.5), DRT18 reverse cutting needle | C2090320 | Comparable by category, not interchangeable 1:1 | Code verified in distribution sources: same base material and gauge; 18 mm reverse cutting needle versus 16 mm DS16. Confirm geometry in official catalogue |
| Medtronic / Covidien | Surgipro™ II – polypropylene/polyethylene copolymer | 4/0 code not verified | Not verified | Copolymer material (not pure polypropylene); pending confirmation of reference and needle geometry against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | 4/0 code not verified | Not verified | Same base material (blue polypropylene monofilament); confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: before substituting in a tender or in the operating theatre, verify one by one: exact gauge, thread length, needle shape and point, needle size, material, colour, surface treatment and regulatory classification (CE/MDR) of the actual product of each manufacturer. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
- Tissue to suture: the DS16 reverse cutting needle is suitable for soft tissues and skin planes that require firm, controlled penetration in areas of limited access (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut range.
- Needle size: the 16 mm DS16 is a compact needle, ideal for superficial planes and microsurgery. If the protocol requires a slightly larger needle in the same USP 4/0 gauge, the DS19 variant (AM732DS1940) from the same Premisut family is available.
- Alternative gauges with the same DS16 needle: USP 3/0 (AM732DS1630) for greater mechanical demand and USP 6/0 (AM732DS1660) for precision ophthalmic and cardiovascular microsurgery.
- Length and presentation: this 75 cm reference provides sufficient margin for secure passes and knots. If your purchasing centre requires a superior quality control profile with an identical configuration, the Premisut Prime version (AMP732DS1640) is available, and for smaller fields the DS19 version of 45 cm (AM731DS1940).
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732DS1640 and the batch number for traceability in the operating theatre and in case of a claim.
For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews