Description
1. Commercial Introduction
The polypropylene suture PREMISUT that Cahnos makes available to surgical services, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a reverse cutting triangular point of 19 mm (DS 19 profile), USP 2/0 gauge and a 75 cm strand in high-visibility blue: a versatile configuration, widely used in soft tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
The product is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and presentation to public tenders. It is supplied in a box of 12 units under the factory reference 732DS1920 (SKU Cahnos AM732DS1920), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS 19 needle of ⅜ circle and reverse cutting triangular point (reverse cutting) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, even in reduced access planes or microsurgery. The USP 2/0 gauge (metric EP 3) offers an excellent balance between handling and tension, common in skin, fascia and ligatures. The blue colour of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut (standard quality, DS 19 needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.300 – 0.349 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, DS profile |
| Needle size | 19 mm (DS 19 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732DS1920 |
| Reference Cahnos (SKU) | AM732DS1920 |
Family Premisut DS 19 (⅜ circle needle, reverse cutting triangular point, blue):
| Quality | USP size | Thread | Reference |
|---|---|---|---|
| Standard | 2/0 | 75 cm | 732DS1920 / AM732DS1920 (this product) |
| Standard | 3/0 | 75 cm | 732DS1930 / AM732DS1930 |
| Standard | 4/0 | 45 cm | 731DS1940 / AM731DS1940 |
| Standard | 4/0 | 75 cm | 732DS1940 / AM732DS1940 |
| Standard | 6/0 | 75 cm | 732DS1960 / AM732DS1960 |
| Prime | 2/0 | 75 cm | P732DS1920 / AMP732DS1920 |
| Prime | 2/0 | 2 × 75 cm | P732DS1920.2 / AMP732DS1920.2 |
4. Equivalences and Cross-References
Reference 732DS1920 corresponds to the official nomenclature of the Premisut range (DS 19 profile, reverse cutting triangular point, standard quality) and is marketed by Cahnos keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene DS 19 Prime, USP 2/0, blue, 75 cm | P732DS1920 / AMP732DS1920 | Direct range equivalent | Same needle, gauge, colour and length; Prime quality (premium grooved needle) versus standard |
| Cahnos (Premisut Prime) | Polypropylene DS 19 Prime, USP 2/0, blue, 2 × 75 cm | P732DS1920.2 / AMP732DS1920.2 | Configuration equivalent | Same DS 19 needle and gauge; presentation in double strand of 75 cm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 75 cm, FSLX 3/8 circle reverse cutting needle | 8689H | Comparable by category, not interchangeable 1:1 | Matches in material, gauge, colour and length; FSLX needle of larger size (40 mm) versus DS 19. Commercial presentation in box of 36 units; confirm batch and CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 2/0 (EP 3), 75 cm, DS 19 needle | C2095522 | Comparable by category, not interchangeable 1:1 | Same base material, gauge and DS needle of 19 mm; confirm exact geometry and presentation in official data sheet |
| B. Braun (Aesculap) | Optilene® – copolymer of polypropylene and polyethylene, blue, 2/0, 75 cm, DS 19 needle | C3095522 | Comparable by category, not interchangeable 1:1 | Copolymer (not pure polypropylene) with DS 19 needle of 19 mm; verify IFU and presentation |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 2/0, 75 cm, C-15 3/8 circle reverse cutting needle | SP685 | Comparable by category, not interchangeable 1:1 | Same gauge, colour and length; reverse cutting needle of smaller size and copolymer material; confirm reference and batch against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, 2/0, 75 cm, DS-21 needle | CO303497 | Comparable by category, not interchangeable 1:1 | Blue polypropylene monofilament 2/0 of 75 cm with DS-21 needle (21 mm); verify batch and presentation |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the USP 2/0 gauge (metric EP 3) is the usual choice for medium tension planes such as skin, fascia, subcutaneous tissue and ligatures. For more delicate microsurgery planes (ophthalmology, neurosurgery) consider the 4/0 (AM732DS1940) or 6/0 (AM732DS1960) gauges of the same DS 19 family, and for greater mechanical demand the 3/0 (AM732DS1930).
- Needle size: the DS 19 of 19 mm is a compact needle, suitable for superficial planes, microsurgery and surgical fields with reduced access; for wider planes, the DS 24, DS 26, DS 30 and DS 40 variants are available within the Premisut family in USP 2/0 gauge (AM732DS2420, AM732DS2620, AM732DS3020, AM732DS4020). For lax or vascular tissues, consider round point profiles (HR) from the same range.
- Length and presentation: this 75 cm reference provides sufficient margin for secure passes and knots; if the protocol requires a superior finish, the Premisut Prime range (AMP732DS1920 in single thread or AMP732DS1920.2 in double 75 cm thread) maintains the same needle and configuration.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732DS1920 and the batch number for traceability in the operating theatre and in the event of a claim.
- For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews