Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments and purchasing centres seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 3/0 gauge, with a ⅜ circle needle of 40 mm with a triangular reverse cutting grooved point and two 75 cm threads in blue, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital purchasing management and presentation for tenders. Available at Cahnos under the factory reference P732RDS4030.2 (SKU AMP732RDS4030.2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, exceeding the requirements of USP and European Pharmacopoeia standards, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 40 Prime needle (⅜ circle, triangular reverse cutting grooved point of 40 mm) is designed to penetrate soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the thread facilitates smooth and consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 2 strands of 75 cm (2 × 75 cm) |
| Thread colour | Identification blue |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 40 mm (DS 40 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732RDS4030.2 |
| Reference Cahnos (SKU) | AMP732RDS4030.2 |
4. Equivalences and Cross-References
The reference P732RDS4030.2 corresponds to the official nomenclature of the Premisut Prime range (DS 40 Prime profile, two 75 cm threads). Cahnos markets the product keeping the factory reference without altering characters: no digit should be added, removed or reordered when ordering or bidding. The DS needle profile (reverse cutting) is interchangeable within the Premisut system itself, varying only the needle size or gauge.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 40 Prime 3/0 blue 2 × 75 cm | P732RDS4030.2 / AMP732RDS4030.2 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 24 Prime 3/0 blue 2 × 75 cm | AMP732DS2430.2 | Direct range equivalent (needle varies) | Same family, gauge, colour and presentation 2 × 75 cm; DS needle of 24 mm versus 40 mm. Interchangeable within the Premisut system |
| Premisut Prime range (Cahnos) | Polypropylene DS 19 Prime 3/0 blue 2 × 75 cm | AMP732DS1930.2 | Direct range equivalent (needle varies) | Same family, gauge, colour and presentation; DS needle of 19 mm versus 40 mm |
| Premisut Prime range (Cahnos) | Polypropylene DS 40 Prime 0 blue 75 cm | 732DS4010 | Comparable within the same system | Same DS 40 mm needle; gauge changes to USP 0 and presentation to a single 75 cm thread |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® FSLX (reverse cutting, 40 mm, 3/8 circle) | 8649H | Functional equivalence by specifications (no official cross-reference table) | Blue polypropylene monofilament 3/0, 75 cm, 3/8 circle reverse cutting needle of 40 mm (FSLX). Matches in gauge, length, colour and needle geometry; presentation in box of 36 units. Confirm lot and presentation |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® KS (reverse cutting) | 8622H | Comparable by category, not interchangeable 1:1 | Same gauge 3/0, blue 75 cm thread and reverse cutting point, but KS needle of smaller size versus 40 mm. Verify geometry according to tissue |
| B. Braun | Premilene® / Optilene® (polypropylene, Easyslide reverse cutting DS needles) | C0090246 (3-0, 75 cm, DS30) and DS19 variants | Comparable by category, not interchangeable 1:1 | Same base material, gauge and length; the DS needles from B. Braun available are of smaller size (19–30 mm) than the DS 40. Confirm needle geometry in official catalogue |
| Medtronic (Covidien) | Surgipro™ II (polypropylene with polyethylene) | SP-675 (C-16 needle, 3/8, reverse cutting) | Comparable by category, not interchangeable 1:1 | Polypropylene copolymer with polyethylene in blue 3/0, 75 cm and 3/8 reverse cutting needle, but C-16 needle of smaller size than DS 40. Confirm reference and lot against IFU |
| Serag-Wiessner | SERAPREN® (blue polypropylene monofilament) | Consult code according to gauge and needle | Comparable by category, not interchangeable 1:1 | Blue non-absorbable polypropylene monofilament in USP gauges 8/0 to 0. Verify gauge, needle geometry and lengths with the distributor |
Mandatory technical note: there is no manufacturer-validated equivalence table cross-referencing this product with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution. Consult the technical department at Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the DS reverse cutting grooved needle is suitable for soft and flat skin tissues requiring firm and controlled penetration (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
Needle size: the 40 mm DS is a generous-length needle, indicated for wide suture planes or access to deep tissue; for smaller areas, the DS 24 (AMP732DS2430.2) and DS 19 (AMP732DS1930.2) variants are available in the same gauge and 2 × 75 cm presentation.
Gauge: USP 3/0 is versatile for soft tissues and medium-tension ligatures; for higher-tension planes, USP 0 gauge with the same DS 40 needle (REF. 732DS4010) may be considered.
Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use. Retain the reference P732RDS4030.2 and the batch number for traceability in the operating theatre and in the event of a complaint.





Reviews