Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a triangular reverse cutting grooved point of 19 mm (DS 19 Prime profile), USP gauge 2/0 and a 75 cm strand in high-visibility blue: a versatile configuration, widely used in soft tissues, ligatures and procedures in cardiovascular surgery, ophthalmology, neurosurgery and general surgery.
The product is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Cahnos markets this reference under the factory code P732DS1920 (SKU AMP732DS1920), keeping the original nomenclature intact: no character may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS 19 Prime needle (⅜ circle, triangular reverse cutting grooved point of 19 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, especially useful in superficial planes and areas of reduced access. The grooved finish of the needle body and thread facilitates smooth and consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.300 – 0.349 mm (according to USP Pharmacopoeia) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 19 mm (DS 19 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS1920 |
| Reference Cahnos (SKU) | AMP732DS1920 |
Family Premisut Prime DS 19 (⅜ circle needle, triangular reverse cutting grooved point, blue):
| Needle profile | USP size | Presentation | Reference |
| DS 19 Prime | 2/0 | 1 × 75 cm | P732DS1920 (this product) |
| DS 19 Prime | 2/0 | 2 × 75 cm | P732DS1920.2 |
| DS 19 Prime | 3/0 | 1 × 75 cm | P732DS1930 |
| DS 19 Prime | 3/0 | 2 × 75 cm | P732DS1930.2 |
| DS 19 Prime | 4/0 | 1 × 75 cm | P732DS1940 |
| DS 19 Prime | 6/0 | 1 × 75 cm | P732DS1960 |
4. Equivalences and Cross-References
The reference P732DS1920 corresponds to the official nomenclature of the Premisut Prime range (DS 19 Prime profile, single 75 cm thread). The DS needle profile (reverse cutting) is interchangeable within the Premisut system itself, varying only the needle size or gauge. Comparisons with other brands are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 19 Prime, USP 2/0, blue, 2 × 75 cm | AMP732DS1920.2 / P732DS1920.2 | Configuration equivalent within the same system | Same DS 19 needle and USP gauge 2/0; presentation changes to 2 threads of 75 cm. |
| Premisut (Cahnos – standard quality) | Polypropylene DS 19, USP 2/0, blue, 75 cm | AM732DS1920 | Functional category equivalent | Same needle geometry, gauge and length; standard quality, needle without Prime grooved body. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE – blue polypropylene monofilament, USP 2/0, 75 cm, FSLX 3/8 circle reverse cutting needle. | 8689H | Functional equivalence by specifications (no official cross-reference table) | Code verified in Ethicon catalogue: matches in material, gauge, colour and length; FSLX needle of larger size (40 mm) compared to DS 19. Confirm batch and CE/MDR traceability against the IFU. |
| B. Braun (Aesculap) | Premilene – blue polypropylene monofilament, 2/0 (EP 3), 75 cm, DS19 needle. | C2095522 | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue: same base material, gauge and DS needle of 19 mm; confirm exact geometry and presentation in official data sheet. |
| B. Braun (Aesculap) | Optilene – copolymer of polypropylene and polyethylene, blue, 2/0, 75 cm, DS19 needle. | C3095522 | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue: copolymer (not pure polypropylene) with DS19 needle of 19 mm; verify IFU and presentation. |
| Medtronic (Covidien) | Surgipro II – copolymer of polypropylene with polyethylene, blue, 2/0, 75 cm, C-15 3/8 circle reverse cutting needle. | SP685 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: copolymer in gauge 2/0 blue and 75 cm with reverse cutting needle; confirm reference and batch against the IFU. |
| Serag-Wiessner | SERAPREN – blue polypropylene monofilament, 2/0, 75 cm, DS-21 needle. | CO303497 | Comparable by category, not interchangeable 1:1 | Code verified in SERAPREN catalogue: blue polypropylene monofilament 2/0 of 75 cm with DS-21 needle (21 mm); verify batch and presentation. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE, Premilene, Optilene, Surgipro or SERAPREN are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: USP gauge 2/0 (metric EP 3) is the usual choice for medium-tension planes such as skin, fascia, subcutaneous tissue and ligatures; for more delicate microsurgery planes (ophthalmology, neurosurgery) consider gauges 4/0, 5/0 or 6/0 from the same DS 19 family, and for planes of higher mechanical tension, USP gauge 0.
Needle size: the DS 19 is a short needle, ideal for surgical fields with reduced access and superficial planes; for wider fields or deep tissue, variants DS 24 (AMP732DS2430.2), DS 30 (AMP732DS3030.2) or DS 40 (AMP732RDS4030.2) are available within the same Premisut Prime system.
Presentation: the 2 × 75 cm version (AMP732DS1920.2) reduces the number of packages opened per procedure compared with the single-thread version; if you prefer a more economical alternative, the standard quality Premisut (AM732DS1920) keeps the same needle and configuration. Within the same DS 19 Prime profile, the range also covers gauges 3/0 (AMP732DS1930), 4/0 (AMP732DS1940) and 6/0 (AMP732DS1960), allowing you to unify supplier across the entire permanent suture portfolio.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS1920 and the batch number for traceability in the operating theatre and in the event of a claim. For B2B volume conditions, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews