Description
1. Product Presentation
The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with total control is required. This presentation incorporates a ⅜ circle needle with a triangular reverse cutting grooved point of 19 mm (DS 19 Prime profile), USP 3/0 gauge and two strands of 75 cm in high-visibility blue: a very practical configuration for procedures requiring multiple passes or a continuous suture without opening additional packages.
It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available under the SKU Cahnos AMP732DS1930.2, corresponding to the Premisut Prime DS 19 range (⅜ circle needle, triangular reverse cutting grooved point, blue thread).
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 19 Prime needle (⅜ circle, triangular reverse cutting grooved point of 19 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, especially useful in superficial planes and areas of limited access. The grooved finish of the needle and thread facilitates smooth and consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (according to USP Pharmacopoeia) |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 19 mm (DS 19 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Reference Cahnos (SKU) | AMP732DS1930.2 |
4. Equivalences and Cross-References
The reference AMP732DS1930.2 corresponds to the double presentation (2 × 75 cm) of the Premisut Prime range with DS 19 Prime needle profile. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polypropylene DS 19 Prime, USP 3/0, blue, 1 × 75 cm | AMP732DS1930 (P732DS1930) | Direct range equivalent (presentation varies) | Same DS 19 needle, gauge, colour and quality; 1 thread of 75 cm versus 2 threads |
| Ethicon (J&J MedTech) | PROLENE – blue monofilament polypropylene, FS-1 3/8 circle reverse cutting needle | EH7694H | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: matches in material, gauge 3/0, blue thread of 75 cm and needle geometry 3/8 reverse cutting; needle of 24 mm versus 19 mm. Confirm batch and CE/MDR traceability against the IFU |
| Ethicon (J&J MedTech) | PROLENE – blue monofilament polypropylene, FSLX 3/8 circle reverse cutting needle 40 mm | 8649H | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: same material, gauge, colour and length, but needle of 40 mm notably larger; commercial pack of 36 units. |
| Ethicon (J&J MedTech) | PROLENE – KS straight cutting needle | 8622H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue: same gauge 3/0, blue thread of 75 cm and material, but straight needle (not curved ⅜ circle); needle geometry not equivalent for deep surgery |
| B. Braun (Aesculap) | Premilene – blue monofilament polypropylene, DS30 needle (reverse cutting) | C0090246 (3/0, 75 cm, DS30) | Comparable by category, not interchangeable 1:1 | Code verified in catalogue/distribution sources: same base material, gauge and length, but needle of 30 mm versus 19 mm. Confirm exact geometry in official catalogue |
| Medtronic (Covidien) | Surgipro II – copolymer of polypropylene with polyethylene, C-16 3/8 reverse cutting needle | SP-675 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: copolymer material (not pure polypropylene) in gauge 3/0 blue and 75 cm; confirm reference and batch against the IFU |
| Serag-Wiessner | SERAPREN – blue monofilament polypropylene, DS-30 reverse cutting needle | CO203416 (3/0, 75 cm, DS-30) | Comparable by category, not interchangeable 1:1 | Code verified in official SERAPREN catalogue: blue monofilament polypropylene 3/0 of 75 cm with DS-30 needle; needle of 30 mm versus 19 mm. Note: the code CO353416 cited in other tables corresponds to USP 0 with DS-30, not to 3/0 |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the comparisons with PROLENE, Premilene, Surgipro or SERAPREN are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the DS reverse cutting grooved needle is suitable for soft tissues and skin planes that require firm and controlled penetration (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
- Needle size: the DS 19, 19 mm, is ideal for superficial planes and areas of limited access; for wider fields it is available in the DS 30 (AMP732DS3030.2), DS 36 (AMP732DS3630.2) or DS 40 (AMP732RDS4030.2) variants in the same USP 3/0 gauge.
- Gauge: USP 3/0 (metric 2) is versatile for soft tissues and medium-tension ligatures; for greater mechanical demands consider USP 0 and for delicate tissues USP 4/0 (AMP732DS1940) with the same DS 19 needle.
- Double presentation: the 2 × 75 cm version reduces the number of packages opened per procedure compared with the single-thread version (AMP732DS1930); if a single thread is required, this alternative is available with the same needle and quality.
- Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference and batch number for traceability in the operating theatre and in the event of a claim. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews