Description
1. Commercial Introduction
The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a 12 mm reverse cutting triangular point (DS12 Prime profile), USP 6/0 gauge and a 45 cm strand in high-visibility blue: a configuration of maximum fineness, widely used in superficial planes, very delicate tissues, ligatures and microsurgery, cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
It is supplied sterile, ready for single use, with batch traceability, facilitating hospital stock management and submission to public tenders. Available under the factory reference P731DS1260 (SKU Cahnos AMP731DS1260), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS12 Prime needle (⅜ circle, 12 mm reverse cutting triangular point) penetrates soft and poorly distensible tissues with a clean, stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, reducing the risk of tearing in firm tissues and allowing controlled passage, even in restricted access planes or microsurgery. The USP 6/0 gauge (EP metric 0.7) is one of the finest in the range, designed for precision sutures on delicate structures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, DS12 needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric EP 0.7); conforms to USP and European Pharmacopoeia sizes |
| Thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, DS profile |
| Needle size | 12 mm (DS12 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P731DS1260 |
| Reference Cahnos (SKU) | AMP731DS1260 |
Premisut Prime DS12 family (⅜ circle needle, reverse cutting triangular point, blue):
| Needle profile | USP size | Thread | Reference |
| DS12 Prime | 6/0 | 45 cm | P731DS1260 / AMP731DS1260 (this product) |
| DS12 Prime | 7/0 | 45 cm | P731DS1270 / AMP731DS1270 |
| DS12 Prime | 5/0 | 45 cm | P731DS1250 / AMP731DS1250 |
| DS12 Prime | 4/0 | 75 cm | P732DS1240 / AMP732DS1240 |
| DS10 Prime | 6/0 | 45 cm | P731DS1060 / AMP731DS1060 |
| DS16 Prime | 6/0 | 45 cm | P731DS1660 / AMP731DS1660 |
| DS16 Prime | 6/0 | 75 cm | P732DS1660 / AMP732DS1660 |
4. Equivalences and Cross-References
Reference P731DS1260 corresponds to the official nomenclature of the Premisut Prime range (DS12 Prime profile, single 45 cm strand, USP 6/0 gauge). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene DS12 Prime, USP 6/0, blue, 45 cm | P731DS1260 / AMP731DS1260 | Analysed product | Reference for this datasheet |
| Cahnos (Premisut Prime) | Polypropylene DS10 Prime, USP 6/0, blue, 45 cm | P731DS1060 / AMP731DS1060 | Functional equivalent within the system | Same gauge, quality and colour; DS10 needle of 10 mm versus DS12 of 12 mm |
| Cahnos (Premisut Prime) | Polypropylene DS16 Prime, USP 6/0, blue, 45 cm | P731DS1660 / AMP731DS1660 | Functional equivalent within the system | Same gauge, quality and colour; DS16 needle of 16 mm versus DS12 of 12 mm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 6/0, P-3 ⅜ circle precision reverse cutting needle, 13 mm, 45 cm | 8695G | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same material, gauge and colour; P-3 needle of 13 mm versus DS12 of 12 mm; confirm batch and CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 6/0, ⅜ circle precision reverse cutting needle, 13 mm, 45 cm | C2090618 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same base material and gauge; 13 mm needle versus DS12 of 12 mm; confirm exact geometry in official catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, 6/0, blue, PS-3 reverse cutting ⅜ needle of 16 mm | SP5680G | Comparable by category, not interchangeable 1:1 | Code verified in distribution cross-reference tables: same needle configuration and gauge; copolymer material (not pure polypropylene); 16 mm needle. Confirm exact geometry in IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or substitution. The needle geometry (DS12, reverse cutting) is only fully safely interchangeable within the Premisut system itself. Consult Cahnos’s technical department to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery, cardiovascular surgery) and fine skin. The DS12 reverse cutting needle penetrates soft and poorly distensible tissues with control in restricted access areas; for lax or vascular tissues consider conical point profiles (DR/HR) from the same Premisut Prime range.
- Needle size: the 12 mm DS12 is compact and ideal for superficial planes and limited surgical fields. If the protocol requires an even shorter needle in the same 6/0 gauge, the DS10 variant (AMP731DS1060) is available; if a longer needle is required, the DS16 (AMP731DS1660 / AMP732DS1660) or DS19 (AMP731DS1960 / AMP732DS1960) from the same Prime family.
- Alternative gauges with the same DS12 needle: USP 7/0 (AMP731DS1270) for maximum fineness, USP 5/0 (AMP731DS1250) and USP 4/0 in 75 cm (AMP732DS1240) allow supplier consolidation across the entire permanent suture portfolio.
- Length and presentation: this 45 cm reference is compact, designed for short passes or limited fields; for longer sutures in the same profile, the DS16/DS19 family is available in 75 cm.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P731DS1260 and the batch number for traceability in the operating theatre and in case of complaint.
- B2B conditions: for hospital supply agreements, public tenders or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.