We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Non-absorbable polypropylene suture Premisut, 3/8 circle needle, triangular reverse cutting point, DS 40 mm, USP 2/0, blue thread 75 cm – Box of 12 units (Ref. 732DS4020)

17,59 €

Non-absorbable surgical suture of monofilament polypropylene Premisut, USP gauge 2/0, blue thread of 75 cm mounted on a ⅜ circle needle with a triangular reverse cutting grooved point of 40 mm (DS 40 profile). Uncoated and non-absorbable: gradual encapsulation with wound support for more than three months. Sterilised by ethylene oxide and ready for the operating theatre; indicated for approximation of soft tissues, ligatures and cardiovascular surgery, ophthalmology and neurosurgery. Price per box of 12 units (individual sterile sachets). Factory ref. 732DS4020 · Ref. Cahnos AM732DS4020.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM732DS4020

Description

1. Commercial Introduction

The polypropylene suture Premisut that we offer at Cahnos is the reference solution for the closure and approximation of soft tissues in high-demand procedures. Its uncoated monofilament design, its highly visible grooved blue colour and its ⅜ circle needle with a 40 mm reverse cutting triangular point (DS 40 profile) offer excellent mechanical behaviour and minimal tissue reaction. It is presented in a box of 12 units sterilised by ethylene oxide, ready for immediate use in the operating theatre and with batch traceability, facilitating hospital purchasing management and presentation for tenders.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. As it lacks interstices, it does not produce a wick effect, reduces bacterial adherence and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase. This property makes it the classic choice in cardiovascular, vascular, ophthalmic and neurosurgery.

The ⅜ circle needle with reverse cutting triangular point (DS profile, body and point) penetrates firm, inelastic tissues with a clean, stable cut, minimising the risk of tearing. The grooved finish of the thread facilitates smooth and consistent delivery during knotting. The product is supplied sterile, is single-use and cannot be re-sterilised.

3. Technical Specifications

Line reference 732DS4020
Reference Cahnos (SKU) AM732DS4020
Brand / Quality Premisut – standard quality
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Monofilament with grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 2/0 (metric 3)
Thread length 75 cm
Thread colour Identification blue (high visibility in the surgical field)
Needle shape ⅜ circle (3/8)
Needle type Reverse cutting triangular point, body and point (DS profile), grooved
Needle size 40 mm (DS 40 profile)
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (individual sterile sachets)

Gauge equivalence (indicative, according to USP Pharmacopoeia):

USP size Metric size Approximate diameter
2/0 3 0.300 – 0.339 mm (non-absorbable suture)

4. Equivalences and Cross-References

Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market. The reference commercial ranges are Prolene® (Ethicon / Johnson & Johnson), Premilene® and Optilene® (B. Braun) and Surgipro™ II (Medtronic / Covidien). The following details the references from Cahnos’s own catalogue with identical or very close configuration, as well as the families of other manufacturers in the sector. There is no official equivalence table validated by the manufacturer that cross-references this reference against other brands; comparisons between brands are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet and IFU before use in tenders or substitution. Consult Cahnos’s technical department to validate any equivalence.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Differences / Notes
Cahnos (Premisut) Polypropylene 3/8 DS 30, USP 2/0, blue, 75 cm 732DS3020 (AM732DS3020) Functional equivalent within the same system Same material, gauge, colour and thread length; DS 30 needle of 30 mm (10 mm shorter than the DS 40)
Cahnos (Premisut) Polypropylene 3/8 DS 26 and DS 24, USP 2/0, blue, 75 cm AM732DS2620 · AM732DS2420 Functional equivalent within the same system Same material, gauge, colour and length; smaller DS needles, for more superficial planes
Ethicon (J&J MedTech) Prolene® – blue monofilament polypropylene, FSLX reverse cutting 3/8 needle of 40 mm 8689H (USP 2-0, 75 cm) Functional equivalence by specifications, not interchangeable 1:1 without validation Matches in gauge, length, colour and needle size (FSLX 40 mm); commercial presentation in box of 36 units; confirm packaging and batch against IFU
Ethicon (J&J MedTech) Prolene® – FS and KS reverse cutting needles 8666H (FS) · 8623H (KS), USP 2-0, 75 cm Comparable by category, not interchangeable 1:1 Same material, gauge, colour and length; needles smaller than the DS 40; verify geometry according to tissue
B. Braun Optilene® – polypropylene monofilament with polyethylene, DS needle C3090247 (DS 30) · C3090236 (DS 24), 2/0, 75 cm Comparable by category, not interchangeable 1:1 Copolymer of polypropylene and polyethylene (not pure polypropylene); DS needles of 24–30 mm, smaller than the DS 40; confirm in official catalogue before substituting
Medtronic (Covidien) Surgipro™ II – copolymer of polypropylene with polyethylene, C-15 3/8 reverse cutting needle SP685 (2-0, blue, 75 cm) Comparable by category, not interchangeable 1:1 Same gauge, colour and length; C-15 needle smaller than the DS 40 and copolymer material; confirm reference and batch against IFU
Resorba RESOPREN® – PVDF monofilament (alternative material, not polypropylene) Pending confirmation for USP 2/0 DS 40 Not verified PVDF material (not polypropylene); verify code, gauge and needle geometry with the manufacturer before any substitution

Technical note: before any formal substitution, verify in the alternative manufacturer’s technical data sheet the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

To choose the most appropriate suture, assess the needle size and gauge according to the anatomical area. The DS 40 needle of 40 mm in ⅜ circle with reverse cutting is ideal for deep planes and medium-thickness tissues; for more superficial planes, DS 30, DS 26, DS 24 or DS 19 are available within the same Premisut family with USP 2/0 gauge. USP 2/0 gauge (metric 3) offers an excellent balance between handling and tension, widely used in soft tissue approximation, vascular ligatures and wall closures.

Variants of interest within the Cahnos catalogue: AM732DS3020 (DS 30, USP 2/0), AM732DS2620 (DS 26, USP 2/0), AM732DS2420 (DS 24, USP 2/0), AM732DS1920 (DS 19, USP 2/0) and, for other gauges with the same DS 40 needle, AM732DS4010 (USP 0) and AM732DS4030 (USP 3/0); in Prime quality with double thread, AMP732RDS4030.2. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polypropylene monofilament, uncoated

Structure

Monofilament with grooved surface

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 2/0 (metric 3)

Needle shape

⅜ circle (3/8)

Needle tip

Reverse cutting triangular (body and point), grooved

Needle size

DS 40 (40 mm)

Sterilisation

Ethylene oxide (EO)

Use

Sterile, single-use, non-resterilizable

Presentation

Box of 12 units

Manufacturer reference

732DS4020

Indications

Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Medida de aguja

DS 40

Usp

2/0

Color

Blue

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polypropylene suture Premisut, 3/8 circle needle, triangular reverse cutting point, DS 40 mm, USP 2/0, blue thread 75 cm – Box of 12 units (Ref. 732DS4020)”

Your email address will not be published. Required fields are marked *