Description
1. Commercial Introduction
The polypropylene suture PREMISUT that Cahnos makes available to surgical departments, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a reverse cutting triangular point of 19 mm (DS 19 profile), USP 3/0 gauge and a 75 cm strand in high-visibility blue: a versatile configuration, widely used in soft tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
The product is supplied sterile, ready for single use and with batch traceability, facilitating the management of hospital stock and presentation to public tenders. It is supplied in a box of 12 units under the factory reference 732DS1930 (SKU Cahnos AM732DS1930), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 19 needle of ⅜ circle and reverse cutting triangular point penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, even in reduced access planes or microsurgery. The USP 3/0 gauge (EP metric 2) offers a good balance between handling and tension, common in skin, subcutaneous tissue and ligatures. The blue colour of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut (standard quality, DS 19 needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, DS profile |
| Needle size | 19 mm (DS 19 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732DS1930 |
| Reference Cahnos (SKU) | AM732DS1930 |
Premisut DS 19 family (⅜ circle needle, reverse cutting triangular point, blue):
| Quality | USP size | Thread | Reference |
|---|---|---|---|
| Standard | 3/0 | 45 cm | 731DS1930 / AM731DS1930 |
| Standard | 3/0 | 75 cm | 732DS1930 / AM732DS1930 (this product) |
| Standard | 4/0 | 75 cm | 732DS1940 / AM732DS1940 |
| Standard | 6/0 | 75 cm | 732DS1960 / AM732DS1960 |
| Prime | 3/0 | 75 cm | P732DS1930 / AMP732DS1930 |
4. Equivalences and Cross-References
Reference 732DS1930 corresponds to the official nomenclature of the Premisut range (DS 19 profile, reverse cutting triangular point, standard quality) and is marketed by Cahnos keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene DS 19 Prime, USP 3/0, blue, 75 cm | P732DS1930 / AMP732DS1930 | Direct range equivalent | Same DS 19 needle, gauge, colour and length; Prime quality (premium grooved needle) versus standard |
| Cahnos (Premisut) | Polypropylene DS 19, USP 3/0, blue, 45 cm | 731DS1930 / AM731DS1930 | Equivalent presentation | Same needle and gauge; 45 cm thread versus 75 cm |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 3/0 (EP 2), 75 cm, DS 19 reverse cutting needle | C2090521 | Comparable by category, very close (verify 1:1 in IFU) | Code verified in official catalogue B. Braun and GUDID: material, gauge, length, colour and DS 19 needle of 19 mm match; commercial presentation in box of 36 units. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 3/0, 75 cm, FS-1 reverse cutting needle | EH7694H | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: same material, gauge, colour and length; FS-1 needle of 24 mm versus DS 19 of 19 mm. Confirm batch and CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Optilene® – copolymer of polypropylene and polyethylene, blue, 3/0, 75 cm, DS 19 needle | C3090521 | Comparable by category, not interchangeable 1:1 | Code verified in official catalogue: same DS 19 needle and gauge, but copolymer material (not pure polypropylene); verify IFU and presentation |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 3/0, 45 cm, C-13 reverse cutting needle 19 mm | SP-665 / SP-665G | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: 3/0 blue gauge and 19 mm needle, but 45 cm thread and copolymer material; confirm reference and batch against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, USP 3/0, 75 cm | CO20341M / CO20341N (depending on needle) | Comparable by category, pending confirmation | Same base material (blue polypropylene monofilament) and gauge; confirm the DS 19 needle variant and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this product with other brands; comparisons with PROLENE®, Premilene®, Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the DS 19 reverse cutting needle is suitable for soft, flat skin tissues requiring firm, controlled penetration in areas with limited access (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point (HR) profiles from the same Premisut range.
- Needle size: the 19 mm DS 19 is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space; for larger planes, the DS 24 and DS 30 variants are available within the Premisut family in USP 3/0 gauge (AM732DS2430, AM732DS3030).
- Alternative gauges with the same DS 19 needle: USP 2/0 (AM732DS1920) for higher mechanical demands, USP 4/0 (AM732DS1940) for delicate tissues and USP 6/0 (AM732DS1960) for precision ophthalmic and cardiovascular microsurgery.
- Thread length: this 75 cm reference provides sufficient margin for secure passes and knots; for smaller fields, a 45 cm version is available (AM731DS1930) and, if the protocol requires a superior finish, the Premisut Prime range (AMP732DS1930 in 75 cm), which maintains the same needle and configuration.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732DS1930 and the batch number for traceability in the operating theatre and in the event of a claim.
For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews