Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable performance, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 1 gauge, with a ⅜ circle needle with a triangular reverse cutting grooved point of 30 mm (DS 30 Prime profile) and two 75 cm threads in blue, is especially indicated for highly demanding procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for the operating theatre in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos under SKU AMP732RDS3001, in accordance with the official nomenclature of the Premisut Prime range (factory reference P732RDS3001, DS 30 Prime profile, double 75 cm thread, without alteration of characters).
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The DS 30 Prime needle (⅜ circle, triangular reverse cutting grooved point of 30 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 1 (metric 4); conforms to USP and European Pharmacopoeia calibres |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting grooved point (DS profile) |
| Needle size | 30 mm (DS 30 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732RDS3001 |
| Reference Cahnos (SKU) | AMP732RDS3001 |
DS family (⅜ circle reverse cutting) in USP 1 gauge:
| Needle profile | USP | Presentation | Reference |
| DS 30 Prime | 1 | 2 × 75 cm | P732RDS3001 (AMP732RDS3001) |
| DS 30 Prime | 1 | 1 × 75 cm | P732DS3001 (AMP732DS3001) |
| DS 36 Prime | 1 | 2 × 75 cm | P732DS3601.2 (AMP732DS3601.2) |
| DS 36 Prime | 1 | 1 × 75 cm | P732DS3601 (AMP732DS3601) |
4. Equivalences and Cross-References
The reference P732RDS3001 corresponds to the official nomenclature of the Premisut Prime range (DS 30 Prime profile, double 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters; the DS needle profile (reverse cutting) is only interchangeable within the Premisut system itself by varying the needle size or gauge. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 1, blue, 2 × 75 cm | P732RDS3001 / AMP732RDS3001 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 1, blue, 1 × 75 cm | P732DS3001 / AMP732DS3001 | Configuration equivalent within the same system | Same DS 30 needle and USP 1 gauge; the presentation changes to 1 thread of 75 cm. |
| Premisut Prime range (Cahnos) | Polypropylene DS 36 Prime, USP 1, blue, 2 × 75 cm | P732DS3601.2 / AMP732DS3601.2 | Comparable within the same system | Same gauge and presentation; DS needle of 36 mm versus 30 mm |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 0, blue, 2 × 75 cm | AMP732DS3010.2 | Comparable within the same system | Same DS 30 profile and presentation; the USP gauge changes (0 versus 1) |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 1 | No verified 1:1 code for reverse cutting needle 30 mm 3/8 | Comparable by category / pending confirmation | The verified PROLENE USP 1 codes (e.g. 8425H, 8455H, D6958) mount CT-1, CTX or MO-5 needles, mostly with round point; a PROLENE USP 1 with reverse cutting 3/8 of 30 mm has not been confirmed in public sources |
| B. Braun | Premilene® / Optilene® (blue polypropylene monofilament, Easyslide needles) | Line C209xxxx – pending confirmation of 1:1 code for DS 30 USP 1 | Comparable by category / pending confirmation | Same blue polypropylene base; the exact combination of reverse cutting needle 30 mm + USP 1 + 2 × 75 cm has not been verified |
| Medtronic (Covidien) | Surgipro™ II (polypropylene with polyethylene, blue monofilament) | SP series – pending confirmation for USP 1 | Comparable by category / pending confirmation | Copolymer with polyethylene; codes verified in other gauges (e.g. SP-675 in 3/0 with C-16 needle); confirm reference and needle geometry against IFU |
| Serag-Wiessner | SERAPREN® (blue monofilament polypropylene, USP 8/0 to 1) | Consult code according to gauge and needle | Comparable by category / pending confirmation | Non-absorbable blue polypropylene monofilament; verify gauge, size and needle geometry with the distributor |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the DS reverse cutting grooved needle is suitable for soft and flat tissues that require firm and controlled penetration (skin, fascia, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
Needle size: the 30 mm DS is an intermediate needle, suitable for medium suture planes and areas of reduced access; for wider fields it has the DS 36 (AMP732DS3601.2) and DS 40 in the same USP 1 gauge, and for more superficial planes it can be reduced to smaller needles in the range.
Gauge: USP 1 (metric 4) offers high tensile strength, indicated for tissues subjected to considerable tension, ligatures and deep planes; for lower mechanical demand consider USP 0 (AMP732DS3010.2) or USP 2/0 (AMP732RDS3020.2) with the same DS 30 or DS 40 profile.
Presentation: the 2 × 75 cm version reduces the opening of packages per intervention compared to the single thread version (P732DS3001), being practical for continuous sutures or multiple passes.
Verification before use: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date, keep the reference P732RDS3001 and the batch number for traceability in the operating theatre. For B2B volume conditions, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.