Description
1. Commercial Introduction
The polypropylene suture Premisut Prime with double needle ½ circle trocar point (Tapercut) 17 mm is the reference solution for surgical departments, purchasing centres and tenders seeking a high-performance non-absorbable thread with predictable behaviour and minimal tissue reaction. Presented in USP 3/0 gauge, blue colour and 90 cm strand armed at both ends, it allows criteria to be unified in procedures for approximating and ligating soft tissues, as well as in demanding specialties such as cardiovascular surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units with individual sachets and full batch traceability.
2. Technical Explanation
The thread is made of isotactic polypropylene, a linear synthetic polyolefin with high chemical inertness that is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, reduces tissue drag, avoids the sawing effect on delicate tissues and minimises bacterial adherence. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle, ½ circle with cylindrical body and trocar point (Tapercut), combines the firm penetration of a three-edged cutting point with the minimal aggression of a round-point needle: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The double-needle configuration (2×HRT17) allows continuous sutures or anchors with two armed ends without re-threading, optimising surgical time in confined fields. The blue colour ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (premium range, improved finish needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 3/0 (metric EP 2); approx. diameter 0.20–0.249 mm (non-absorbable suture) |
| Thread length | 90 cm (armed at both ends) |
| Thread colour | Blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body / tip | Cylindrical body, trocar point (Tapercut), non-grooved |
| Needle configuration and size | Double needle 2×HRT 17, 17 mm (stainless steel, Prime finish) |
| Number of needles | 2 (double needle) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Factory reference | P733HRT1730-2 |
| SKU Cahnos | AMP733HRT1730-2 |
Gauge equivalence (indicative according to USP/EP Pharmacopoeia)
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm (non-absorbable suture) |
4. Equivalences and Cross-References
The blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (commercially known as the ‘Prolene’ type). There is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Always consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point 2×HRT17, USP 3/0, blue, 90 cm | P733HRT1730-2 (AMP733HRT1730-2) | Exact reference equivalence (identical) | Same product; official factory reference and Cahnos distribution SKU |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point 2×HRT17, USP 2/0, blue, 90 cm | AMP733HRT1720-2 | Range equivalence (not interchangeable 1:1) | Same needle 2×HRT17, colour and length; gauge varies (USP 2/0, larger diameter) |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point HRT17, USP 3/0, blue, 75 cm (single needle) | AMP732HRT1730 | Range equivalence (not interchangeable 1:1) | Same needle geometry and gauge; 75 cm thread and single needle versus double 90 cm |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point 2×HRT25, USP 3/0, blue, 90 cm | AMP733HRT2530-2 | Range equivalence (not interchangeable 1:1) | Same gauge, colour and length; 25 mm needle versus 17 mm |
| B. Braun (Aesculap) | Premilene® polypropylene, USP 3/0 (2), 75 cm, HRT17 trocar-point (Tapercut) ½-circle needle | C2090314 | Comparable by category (not interchangeable 1:1) | Material, gauge, ½ circle shape and 17 mm trocar point profile match; length 75 cm and single needle versus 90 cm double. Reference confirmed in GUDID database (PREMILENE 3/0 (2) 75CM HRT17 (M)) |
| Ethicon (J&J MedTech) | PROLENE® polypropylene, 3/0, 75 cm, RB-1 ½-circle 17 mm needle | 8872H | Comparable by category (not interchangeable 1:1) | Material, gauge and needle size match (17 mm, ½ circle); the RB-1 has a conical point (taper point) versus the trocar point (tapercut) of Premisut. Different penetration profile for fibrous/calcified tissue |
| Medtronic / Covidien | Surgipro™ II polypropylene with polyethylene, 3/0, 75 cm, CV-25 ½-circle needle | VP-760-X | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; conical point needle CV-25 and copolymer material (polypropylene with polyethylene), different composition from the Premisut strand |
Mandatory technical note: before substituting in a tender or operating theatre, verify one by one: exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer), double-needle configuration and regulatory classification (CE/MDR) of the actual product from each manufacturer. There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point (taper point) variant from the same family.
- Double needle 2×HRT17: ideal for continuous suture techniques or anastomosis with two armed ends without re-threading, especially in reduced surgical fields in ophthalmology and neurosurgery. If the approach requires a longer needle path, the 2×HRT25 (AMP733HRT2530-2) or 2×HRT30 variants are available in the range.
- Gauge: USP 3/0 (metric 2) offers an excellent balance between strength and handling for soft tissues of medium tension, cardiovascular surgery and ligatures. With the same HRT17 needle, the USP 2/0 (AMP733HRT1720-2), USP 4/0 (AMP733HRT1740-2) and USP 5/0 (AMP733HRT1750-2) variants are available.
- Presentation: the double-needle version 2 × 90 cm optimises thread utilisation and facilitates continuous sutures; if your protocol prefers a single needle, AMP732HRT1730 (1 × 75 cm, same gauge) is available.
- Prime range: improved needle finish and superior penetration compared to the standard Premisut line; keep the reference P733HRT1730-2 and the batch number for traceability in the operating theatre and in the event of a claim.
- Verification before use: always check the integrity of the blister and the expiry date. Sterile single-use product, not re-sterilisable. For high-volume orders, purchasing centres or tenders, contact our technical-commercial team.





Reviews
There are no reviews yet.