Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double half-circle tapercut needle of 25 mm (2xHRT25 Prime profile), USP 4/0 gauge and a blue strand of 90 cm, a configuration especially indicated for cardiovascular surgery, ophthalmology, neurosurgery and approximation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos under the factory reference P733HRT2540-2 (SKU AMP733HRT2540-2), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with tapercut point combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or fascia with less resistance and without tearing the suture bed. The double-needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The blue non-grooved strand ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / line | Premisut Prime (premium range, polypropylene) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (2xHRT 25) |
| Configuration | Double needle (2 × HRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HRT2540-2 |
| Reference Cahnos (SKU) | AMP733HRT2540-2 |
Family Premisut HRT 25 (1/2 circle, cylindrical body, tapercut point) in Prime quality
| Needle profile | Presentation | Reference |
| 2xHRT 25 Prime | 2 × 90 cm, USP 4/0 (analysed product) | P733HRT2540-2 / AMP733HRT2540-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 3/0 | P733HRT2530-2 / AMP733HRT2530-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
| HRT 25 Prime (single needle) | 1 × 75 cm, USP 4/0 | P732HRT2540 / AMP732HRT2540 |
| HRT 25 Prime (single needle) | 1 × 75 cm, USP 3/0 | P732HRT2530 / AMP732HRT2530 |
4. Equivalences and Cross-References
The reference P733HRT2540-2 corresponds to the official nomenclature of the Premisut Prime range (2xHRT 25 Prime profile, double needle, USP 4/0 gauge, blue thread of 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle tapercut 2xHRT25, USP 4/0, blue, 90 cm | P733HRT2540-2 / AMP733HRT2540-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle tapercut 2xHRT25, USP 3/0, blue, 90 cm | AMP733HRT2530-2 | Configuration equivalent within the same system | Same 2xHRT 25 needle and length; gauge changes to USP 3/0 |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 2/0, blue, 90 cm | AMP733HRT2520-2 | Configuration equivalent within the same system | Same 2xHRT 25 needle and length; gauge changes to USP 2/0 |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle tapercut HRT25, USP 4/0, blue, 75 cm (single needle) | AMP732HRT2540 | Configuration equivalent within the same system | Same HRT 25 needle and gauge; changes to single needle and 75 cm of thread |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 4-0, 90 cm, double V-7 TAPERCUT needle 1/2 circle of 26 mm | 8975H (verified in Ethicon catalogue and authorised distribution; box of 36 units) | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle, tapercut 1/2 circle and length (90 cm); V-7 needle of 26 mm versus HRT of 25 mm and packaging of 36 units. Confirm IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 4/0, 90 cm, 2xDRT18 tapercut | X2090945 / GUDID 04046963698904 | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; DRT18 needle of 18 mm versus HRT 25 mm. Verify IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 4/0, 90 cm, 2xHR22 conical point | C2090976 (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | Same material, gauge and length; HR22 needle of 22 mm with conical point (CV) versus tapercut point. Confirm IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, blue, 4/0, 90 cm, CV-23 conical point | VP557X (authorised distribution; box of 36 units) | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); CV-23 needle of 17 mm conical point versus tapercut of 25 mm. Verify IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering. Consult the technical department at Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tapercut point: choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point variant (HR, Taperpoint) from the same Premisut Prime family.
- USP 4/0 gauge: offers an excellent balance between manageability and support for fine or moderately tense tissues. If greater resistance is required, the same 2xHRT25 needle is available in USP 3/0 (AMP733HRT2530-2) or USP 2/0 (AMP733HRT2520-2). For microsurgery, consider 5/0 gauges from the Premisut range.
- Needle length: the 25 mm HRT offers a good balance between control and penetration in deep fields. For deeper approaches, consider the 30 mm HRT (e.g. AMP733HRT3030-2, USP 3/0) and for smaller fields the 17 mm HRT (AMP733HRT1730-2, USP 3/0).
- Presentation: the double-needle version 2 × 90 cm optimises thread utilisation and facilitates continuous sutures and anastomosis; if your protocol prefers a single needle, P732HRT2540 (1 × 75 cm, USP 4/0) is available.
- Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and retain the reference P733HRT2540-2 and the batch number for traceability in the operating theatre and in case of complaint.