Description
1. Commercial Introduction
The polypropylene suture Premisut 732HRT1740 is the reference choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 4/0 gauge incorporates a ½ circle needle with cylindrical body and trocar point (Tapercut) of 17 mm (HRT 17 profile) and a blue strand of 75 cm: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for individual use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos with the factory reference 732HRT1740 (SKU AM732HRT1740), kept without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence and minimises thread extrusion. As it is not absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The grooved blue strand ensures optimal visibility and better knot grip on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | Premisut (polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 17 mm (HRT 17) |
| Configuration | Single needle (1 × HRT 17) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732HRT1740 |
| Reference Cahnos (SKU) | AM732HRT1740 |
HRT 17 family (½ circle, cylindrical body, trocar point) within the Premisut range:
| USP size | Presentation | Quality | Reference Cahnos |
|---|---|---|---|
| 3/0 | 1 × 75 cm | Standard | AM732HRT1730 |
| 4/0 | 1 × 75 cm | Standard | AM732HRT1740 (product analysed) |
| 5/0 | 1 × 75 cm | Standard | AM732HRT1750 |
| 4/0 | 1 × 75 cm | Prime (premium needle finish) | AMP732HRT1740 |
4. Equivalences and Cross-References
Non-absorbable blue monofilament polypropylene is one of the most standardised permanent suture families on the market (type «Prolene»). There is no official equivalence table validated by the manufacturer that cross-references the 732HRT1740 reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut (Cahnos) | Polypropylene Prime – ½ circle trocar point HRT 17, 4/0 blue, 75 cm | P732HRT1740 / AMP732HRT1740 | Direct equivalence (same system) | Same HRT 17 needle, gauge, colour and length; only the premium needle finish varies. |
| Premisut (Cahnos) | Polypropylene HRT 17, USP 3/0, blue, 75 cm | 732HRT1730 / AM732HRT1730 | Direct equivalent within the same system | Same HRT 17 needle, colour and length; the gauge changes to USP 3/0 (tissues of moderate tension). |
| Premisut (Cahnos) | Polypropylene HRT 17, USP 5/0, blue, 75 cm | 732HRT1750 / AM732HRT1750 | Direct equivalent within the same system | Same HRT 17 needle, colour and length; USP 5/0 gauge for finer tissues. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 4/0 (1.5), 75 cm, HRT 17 needle, ½ circle | C2090315 (GUDID GTIN 04046963632243; confirmed in GUDID database: PREMILENE 4/0 (1.5) 75CM HRT17 (M)) | Comparable at category level (not interchangeable 1:1) | Material, gauge (EP 1.5), length of 75 cm and HRT 17 needle of ½ circle coincide. Needle finish and commercial presentation differ (box of 12 units vs. B. Braun packaging); verify IFU. |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 4-0, 75 cm, V-4 TAPERCUT needle of 17 mm, ⅜ circle | F2828H (verified in Ethicon EMEA catalogue) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length (75 cm), trocar point (Tapercut) and needle size (17 mm) coincide; the arc differs: ⅜ circle versus ½ circle, and presentation in a box of 36 units. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, 4-0, 75 cm, RB-1 needle of 17 mm, ½ circle, taper point | 8871H (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length and needle size (17 mm, ½ circle) coincide, but the RB-1 has a conical point (Taper Point) versus the HRT trocar point (Tapercut): different penetration profile. |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 4-0, 75 cm, CV-23 needle, ½ circle, conical point | VP-871-X (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle with conical point (Taper Point). Copolymer material (polypropylene with polyethylene), composition different from the Premisut strand. |
| B. Braun | Optilene® – copolymer of polypropylene with polyethylene, blue, 4/0 (1.5), 75 cm, HR17 needle conical point | C3090013 (verified in B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Gauge, colour and length coincide; but HR17 needle with conical point (Taper Point) and copolymer material (not pure polypropylene), therefore not interchangeable 1:1. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; before substituting in a tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer) and the regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult the technical department of Cahnos before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point (Taper Point) variant of the same family (AM732HR1740).
Gauge: USP 4/0 (metric 1.5) is very versatile for vascular, cardiovascular and general soft tissue surgery. If greater resistance is required, the same HRT 17 needle is available in USP 3/0 (AM732HRT1730); for finer tissues, 5/0 (AM732HRT1750).
Prime range: the Premisut Prime line (AMP732HRT1740) maintains the same HRT 17 needle geometry with premium finish; useful when the protocol requires superior penetration quality.
Alternative line: if your approach requires a ⅜ circle arc with trocar point, you have the reference AMP732DRT1740 from the Premisut Prime range.
Prior verification: always confirm the complete reference (HRT 17 needle, 4/0 gauge and 75 cm length) on the packaging before use in the operating theatre; check the blister integrity and expiry date. Single-use product, not re-sterilisable.





Reviews