Description
1. Commercial Introduction
The polypropylene suture Premisut is the reference choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a ½ circle trocar point needle (Tapercut) of 17 mm (HRT profile), USP 5/0 gauge and blue strand of 75 cm: a configuration especially indicated for cardiovascular surgery, ophthalmology and neurosurgery, as well as for approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available from Cahnos with factory reference 732HRT1750 (SKU AM732HRT1750), kept literally without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin extruded in the form of uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The blue-coloured strand guarantees optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | Premisut (Polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Thread colour | Blue (high visibility) |
| USP gauge / size | USP 5/0 (metric EP 1) |
| Thread length | 75 cm (1 thread per unit) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 17 mm (HRT 17) |
| Configuration | Single needle (1 × HRT 17) |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732HRT1750 |
| Reference Cahnos (SKU) | AM732HRT1750 |
4. Equivalences and Cross-References
Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (type “Prolene”). There is no official equivalence table validated by the manufacturer that cross-references 732HRT1750 with other brands; the following comparisons are functional, made against the official catalogue and regulatory databases (GUDID), and are not interchangeable 1:1 without prior technical validation against the data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut (Cahnos) | Polypropylene – 1/2 circle trocar point HRT17, 5/0 blue, 75 cm | 732HRT1750 / AM732HRT1750 | Exact reference equivalence (identical) | Official reference of the analysed product. |
| Premisut Prime (Cahnos) | Polypropylene Prime – 1/2 circle trocar point HRT17, 5/0 blue, 75 cm | P732HRT1750 / AMP732HRT1750 | Direct equivalent (same system) | Same needle, gauge, colour and length; only the premium finish of the needle varies in the Prime version. |
| B. Braun (Aesculap) | Premilene® – Polypropylene, 5/0, 75 cm, HRT17 trocar point needle (Tapercut) ½ circle | C2090312 (DDP) / G2090312 (RCP) | Comparable at category level (not interchangeable 1:1) | Material, gauge, length (75 cm), ½ circle shape and 17 mm trocar point profile match; reference confirmed in GUDID database (PREMILENE 5/0 (1) 75CM HRT17 (M)). Needle finish and commercial presentation differ (box of 12 vs. 36); verify IFU. |
| Ethicon (J&J MedTech) | PROLENE® – Polypropylene, 5/0, 75 cm, ACC-1 TAPERCUT® needle | EH8036H | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length and trocar point profile (Tapercut) match, confirmed in authorised distributor data sheets. The exact geometry and size of the ACC-1 needle (curvature and mm) must be confirmed against Ethicon catalogue/IFU before substituting. |
| Medtronic (Covidien) | Surgipro™ II – Polypropylene with polyethylene, blue, 5/0, 75 cm, CV-22 ½ circle needle | VP-710-X | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length (75 cm); reference confirmed in authorised distributor catalogues with CV-22 needle with conical point (Taper Point) ½ circle, not trocar. Copolymer material of polypropylene with polyethylene: composition different from the Premisut strand. |
Technical note: before substituting in a tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer), surface treatment and regulatory classification (CE/MDR) of the actual product from each manufacturer. Consult the technical department at Cahnos before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point (Taper Point) variant from the same family.
- Gauge: USP 5/0 (metric 1) is ideal for fine and delicate tissues, peripheral vascular surgery, ophthalmology and neurosurgery. If you need more body, the same HRT17 needle is available in gauges 4/0 (ref. AM732HRT1740) and 3/0 (ref. AM732HRT1730).
- Needle length: the 17 mm HRT is suitable for surgical fields of medium depth and delicate tissues. For deeper approaches, consider longer needles within the Premisut range.
- Prime version: the Premisut Prime line (ref. AMP732HRT1750) maintains the same technical configuration with improved needle finish; useful when the protocol requires premium penetration quality.
- Prior verification: always confirm the complete reference (HRT17 needle, 5/0 gauge and 75 cm length) on the packaging before use in the operating theatre; check the integrity of the blister and the expiry date. Single-use product, not re-sterilisable.