Description
1. Commercial Introduction
The polypropylene suture Premisut is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½ circle trocar point (Tapercut) needle of 25 mm (profile 2xHRT 25), USP size 2/0 and blue thread 90 cm, a configuration particularly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
Supplied sterile, ready for immediate use, in a box of 12 units with individual pouches and batch traceability. Available at Cahnos with the manufacturer’s reference 733HRT2520-2 (SKU AM733HRT2520-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination and minimises suture extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body, allowing penetration of slightly fibrous tissues, vascular adventitia or fasciae with less resistance and without tearing the suture bed. The double-needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The high-visibility blue thread facilitates identification of the suture and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (2xHRT 25) |
| Configuration | Double needle (2 × HRT) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 733HRT2520-2 |
| Reference Cahnos (SKU) | AM733HRT2520-2 |
3.2. Premisut HRT 25 family (1/2 circle, cylindrical body, trocar point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHRT 25 (standard) | 2 × 90 cm, USP 0 | 733HRT2510-2 / AM733HRT2510-2 |
| 2xHRT 25 (standard) | 2 × 90 cm, USP 2/0 (product analysed) | 733HRT2520-2 / AM733HRT2520-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 0 (non-grooved) | P733HRT2510-2 / AMP733HRT2510-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 3/0 | P733HRT2530-2 / AMP733HRT2530-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 4/0 | P733HRT2540-2 / AMP733HRT2540-2 |
| 2xHRT 30 (standard) | 2 × 90 cm, USP 2/0 | 733HRT3020-2 / AM733HRT3020-2 |
| 2xHRT 30 (standard) | 2 × 90 cm, USP 3/0 | 733HRT3030-2 / AM733HRT3030-2 |
4. Equivalences and Cross-References
The reference 733HRT2520-2 corresponds to the official nomenclature of the Premisut range (profile 2xHRT 25, double needle, USP size 2/0, blue thread 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 2/0, blue, 90 cm | 733HRT2520-2 / AM733HRT2520-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 2/0, blue, 90 cm | P733HRT2520-2 / AMP733HRT2520-2 | Direct equivalent (same system) | Same needle geometry, size, colour and length; the premium needle finish varies (Prime version, non-grooved thread) |
| Premisut (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 0, blue, 90 cm | 733HRT2510-2 / AM733HRT2510-2 | Configuration equivalent within the same system | Same 2xHRT 25 needle and length; the size changes to USP 0 |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 90 cm, double CC-30 TAPERCUT 1/2 circle needle of 31 mm | W8850 (verified in authorised distribution; box of 12 units) | Comparable at category level (not interchangeable 1:1) | Same polypropylene base, double needle, trocar point and length; the CC-30 needle of 31 mm differs from the HRT of 25 mm. Confirm IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 2/0 (metric 3), 90 cm, HRT26 trocar point needle | C2090067 (verified in B. Braun catalogue and authorised distribution) | Comparable at category level (not interchangeable 1:1) | Matches material, size, colour, length and trocar point; HRT26 needle of 26 mm vs. HRT of 25 mm and armed configuration to be confirmed in IFU (double vs. single) |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 2/0, 90 cm (36″), KV-7 tapercutting 1/2 circle needle 26 mm | VP977 (verified in authorised distribution; box of 36 units) | Comparable by category, not interchangeable 1:1 | Copolymer material (polypropylene with polyethylene, not pure polypropylene); KV-7 needle of 26 mm vs. HRT of 25 mm and pack of 36 units. Verify IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the taper point variant (HR, Taperpoint) from the same Premisut family (e.g. AM733HR2520-2, USP 2/0, 90 cm).
- USP size 2/0: offers an excellent balance between strength and manageability, widely used in cardiovascular, vascular and soft tissue surgery under moderate tension. If greater strength is required, the same 2xHRT25 needle is available in USP 0 (AM733HRT2510-2); for finer tissues, consider the 3/0 (AMP733HRT2530-2) or 4/0 (AMP733HRT2540-2) from the range.
- Needle length: the 25 mm HRT offers a good balance between control and penetration in deep fields. For deeper approaches, consider the 30 mm HRT in 2/0 and 3/0 (733HRT3020-2 / 733HRT3030-2).
- Prime range: the Premisut Prime line maintains the same needle geometry with non-grooved thread and improved needle finish; use reference AMP733HRT2520-2 when the protocol requires a premium finish.
- Prior verification: always confirm the complete reference (needle 2xHRT 25, USP size 2/0 and length 90 cm) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not resterilisable.





Reviews