Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture in double-needle configuration is the choice of the professional seeking a non-absorbable, durable closure with minimal tissue reaction in highly demanding procedures. Made from high-purity polypropylene monofilament, uncoated, it combines smooth and consistent sliding with excellent handling, reducing surgical trauma and the wicking effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile, single-use and with full batch traceability. Factory reference P736HR6,560-2 (SKU Cahnos AMP736HR6,560-2), box of 12 units in individual sachets.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not promote bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength over time in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months. The fluted blue colour ensures optimal visibility on the surgical field.
The ½ circular needle with cylindrical body and conical point (HR profile, taperpoint) of 6.5 mm is designed to pass through soft tissues and very fine vascular structures by separating the fibres without cutting them, minimising bleeding and tissue damage: it is a reference geometry in microsurgery, ophthalmology and cardiovascular surgery. The double-needle configuration (two needles mounted on the same 60 cm thread) optimises material use and facilitates continuous suture and anastomosis techniques without rethreading, reducing handling times and contamination risk. The USP 6/0 gauge (metric 0.7) is ideal for microsurgery, delicate planes, fine vascular anastomoses and precision ligatures. Single-use product, sterilised by ethylene oxide (EO); does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Manufacturer reference | P736HR6,560-2 |
| SKU Cahnos | AMP736HR6,560-2 |
| Brand / Quality | PREMISUT PRIME (premium range) |
| Thread material | Polypropylene monofilament, uncoated (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Monofilament, with grooved surface (factory designation: grooved blue) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric 0.7); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia for synthetic non-absorbable suture) |
| Thread length | 60 cm (double needle on the same strand) |
| Thread colour | Grooved blue with high visibility in the surgical field |
| Number of needles | 2 (double-needle configuration) |
| Needle curvature | ½ circle (1/2), cylindrical body |
| Tip type | Taperpoint conical point |
| Needle size | 2 × HR 6.5 mm (Prime quality) |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use, not re-sterilisable |
| Commercial presentation | Box of 12 units in individual sachets; batch traceability |
| Indications | Approximation of soft tissues, surgical ligatures, microsurgery, cardiovascular surgery, ophthalmology and neurosurgery |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
3.3. PREMISUT PRIME HR 6.5 family (½ circle, 6.5 mm Taperpoint taper point) and range variants
| Needle profile | USP size | Presentation | Reference Cahnos |
| 2 × HR 6.5 mm Prime (this product) | 6/0 | 2 × 60 cm, blue, double needle | AMP736HR6,560-2 |
| 2 × HR 6.5 mm Prime | 6/0 | 2 × 45 cm, blue, double needle | AMP731HR6,560-2 |
| 2 × HR 6.5 mm Prime | 7/0 | 2 × 45 cm, blue, double needle | AMP731HR6,570-2 |
| 2 × HR 8 mm Prime | 7/0 | 2 × 60 cm, blue, double needle | AMP736HR870-2 |
| 2 × HR 10 mm Prime | 7/0 | 2 × 60 cm, blue, double needle | AMP736HR1070-2 |
| 2 × HR 10 mm Prime | 6/0 | 2 × 60 cm, blue, double needle | AMP736HR1060-2 |
| HR 10 mm Prime (single needle) | 7/0 | 1 × 45 cm, blue | AMP731HR1070 |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the PREMISUT manufacturer cross-referencing this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue colour, USP 6/0 or 7/0 gauge and double conical-point needle in an arc), not interchangeable 1:1. Before substitution in a tender or in closed clinical protocols, the needle size and number, thread length and presentation must be verified in each brand’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| PREMISUT PRIME (Cahnos) | Polypropylene 1/2 circle conical tip 2×HR6.5 Prime, USP 6/0, blue, 60 cm | P736HR6,560-2 / AMP736HR6,560-2 | Original reference | Double ½ conical needle 6.5 mm, USP 6/0, fluted blue, 60 cm, box of 12 units. |
| PREMISUT PRIME (Cahnos) | Polypropylene 1/2 circle conical tip 2×HR6.5 Prime, USP 6/0, blue, 45 cm | P731HR6,560-2 / AMP731HR6,560-2 | Direct range equivalent | Same HR 6.5 needle, Prime quality, radius and colour; thread length changes (45 cm vs 60 cm). |
| PREMISUT PRIME (Cahnos) | Polypropylene 1/2 circle conical point 2×HR8 Prime, USP 6/0, blue, 60 cm | P736HR860-2 / AMP736HR860-2 | Direct range equivalent | Same gauge, quality and presentation; HR8 needle of 8 mm vs HR 6.5 of 6.5 mm. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 6-0, double needle RB-2 conical tip ½ circle 13 mm, 75 cm | 8711H / EP8711H | Comparable by category, not interchangeable 1:1 | Code verified in official Ethicon catalogue: material, gauge, colour, ½ circle radius, conical point and double armed match; differences: 13 mm needle vs 6.5 mm and 75 cm length vs 60 cm. Confirm CE/MDR traceability against IFU. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle RB-3 conical tip ½ circle 11 mm, 60 cm | 8206H | Comparable by category, very close, not interchangeable 1:1 | Code verified in official Ethicon catalogue and authorised distribution: material, colour, double needle, ½ circle radius and conical point match; differences: 7/0 gauge vs 6/0 and 11 mm needle vs 6.5 mm; pack of 36 units. |
| B. Braun (Aesculap) | PREMILENE® – blue polypropylene monofilament, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | C2090714 (GUDID 04046963691356) | Functional category equivalence (very close) | Reference verified in GUDID/FDA and Aesculap catalogue: material, colour, double needle and length match; differences: 7/0 gauge and DR10 needle of 10 mm vs 6/0 and HR 6.5. Confirm arc geometry in technical data sheet before substitution. |
| B. Braun (Aesculap) | OPTILENE® – blue polypropylene/polyethylene copolymer, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | G3090714 | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: same length and double needle; differences: copolymer material (not pure polypropylene), 7/0 gauge and 10 mm needle vs 6/0 and 6.5 mm. |
| Medtronic (Covidien) | SURGIPRO™ II – blue polypropylene/polyethylene copolymer, 6-0, double needle conical tip, 75 cm | VP706X-2 | Comparable by category, not interchangeable 1:1 | Code verified in authorised Covidien/Medtronic distribution: gauge, colour and conical point match; differences: copolymer material (not pure polypropylene), ⅜ circle CV-11 needle of 13 mm vs ½ circle HR 6.5, and 75 cm thread. Verify IFU and MDR classification. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, 7/0 (0.5), double needle HR-12 conical tip, 75 cm | CP05340C | Comparable by category, not interchangeable 1:1 | Code verified in the official Serag-Wiessner supply programme (2019): same material and double conical needle; differences: 7/0 gauge, HR-12 needle and 75 cm thread vs 6/0, HR 6.5 and 60 cm. Confirm CE marking and traceability. |
Mandatory technical note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer for this reference; consult the Cahnos technical department before use in a tender. This needle geometry (2×HR 6.5, USP 6/0, 60 cm, conical point) is only safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
Tissue to suture: the USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery, cardiovascular surgery) and fine skin. The Taperpoint conical needle separates the fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for firm or poorly distensible tissues consider trocar point (Tapercut) or reverse cutting profiles from the same PREMISUT range.
Family variants in the Cahnos catalogue: For the same HR 6.5 needle in gauge 6/0, there is AMP731HR6,560-2 (45 cm); if you prefer gauge 7/0 with the same needle, references AMP731HR6,570-2 (45 cm); if you prefer a slightly larger needle, there are AMP736HR860-2 (2×HR 8, 6/0, 60 cm), AMP736HR1060-2 (2×HR 10, 6/0, 60 cm) and AMP736HR870-2 or AMP736HR1070-2 (2×HR 8 / 2×HR 10 in 7/0, 60 cm); and for a single HR 10 needle in 7/0 with 45 cm thread, the AMP731HR1070. Unifying the supplier across the entire permanent suture portfolio enables B2B volume conditions.
Presentation: the double-needle version reduces packaging opening per procedure and facilitates continuous sutures and bilateral techniques without rethreading, maximising the use of the 60 cm strand.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P736HR6,560-2 and the batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.