Description
1. Presentation
The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference when a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction is required. This presentation includes a double ½ circle needle with conical point (Taperpoint) of 25 mm (profile 2xHR25), USP 2/0 gauge and two blue threads of 90 cm each (2 x 90 cm): a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability, which facilitates hospital stock management and presentation to public tenders. It is marketed under the factory reference P733HR2520.2-2 (SKU Cahnos AMP733HR2520.2-2), kept without altering characters.
2. Technical explanation
Polypropylene is a synthetic linear polyolefin that is presented as a monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is not absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with conical Taperpoint point passes through soft and friable tissues by separating the fibres without cutting them, minimising trauma to the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends without rethreading, and the presentation in double thread 2 x 90 cm doubles the useful length per unit, optimising performance in high-consumption surgeries. The highly visible grooved blue strand facilitates identification of the thread and the knot on the surgical field, and the Prime quality adds a premium needle finish (grooved body and improved penetration) compared to the standard Premisut quality. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with highly visible fluted surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3; diameter 0.30 – 0.339 mm); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 x 90 cm (2 threads per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 25 mm (2 x HR 25, double needle) |
| Manufacturing quality | Prime (premium needle finish) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P733HR2520.2-2 |
| Reference Cahnos (SKU) | AMP733HR2520.2-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
3.3. Family Premisut 2xHR25 Prime (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
| 2xHR 25 Prime (product analysed) | 2 x 90 cm, USP 2/0 (double thread) | P733HR2520.2-2 / AMP733HR2520.2-2 |
| 2xHR 25 Prime | 90 cm, USP 2/0 (single thread) | P733HR2520-2 / AMP733HR2520-2 |
| 2xHR 25 Prime | 90 cm, USP 3/0 | P733HR2530-2 / AMP733HR2530-2 |
| 2xHR 25 Prime | 90 cm, USP 4/0 | P733HR2540-2 / AMP733HR2540-2 |
| 2xHR 25 Prime VisiBlack | 90 cm, USP 2/0 (black needle) | P733HR2520-2VB / AMP733HR2520-2VB |
| 2xHR 20 Prime | 90 cm, USP 2/0 | P733HR2020-2 / AMP733HR2020-2 |
| 2xHRT 25 Prime (trocar point) | 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
4. Equivalences and Cross-References
Methodological warning: no cross-reference table published and validated by the manufacturer has been found that would allow declaring 1:1 equivalents with other brands. The references indicated below are classified by verified equivalence level and must always be confirmed against the official technical data sheet (IFU) before their substitution in protocol or tender.
| Manufacturer / Brand | Family / Line | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | 1/2 circle 2xHR25, USP 2/0, blue, 90 cm (single thread) | P733HR2520-2 / AMP733HR2520-2 | Direct equivalent (same system) | Same 2xHR25 needle, gauge 2/0 and colour; single thread of 90 cm per unit (less length) and non-grooved surface |
| Cahnos (Premisut) | 1/2 circle 2xHR25, USP 2/0, blue, 90 cm (Normal quality) | 733HR2520-2 / AM733HR2520-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium needle finish changes (Prime versus standard) |
| Cahnos (Premisut Prime) | 1/2 circle 2xHR25, USP 3/0, blue, 2×90 cm | P733HR2530.2-2 / AMP733HR2530.2-2 | Configuration equivalent (same system) | Same 2×90 cm format and 2xHR25 needle; USP 3/0 gauge of smaller diameter |
| B. Braun (Aesculap) | Optilene® 2/0 (3) 90 cm, double needle 1/2 circle, conical point 2xHR26 CV RCP | C3090909 | Comparable by category (not 1:1) | Verified in official catalogue B. Braun: same gauge (EP 3), colour and double needle; the material (copolymer of polypropylene and polyethylene) and the 26 mm needle differ |
| B. Braun (Aesculap) | Premilene® 2/0 (3) 90 cm, double needle 1/2 circle 2xHR26 CV | C2090909 | Comparable by category (not 1:1) | Polypropylene monofilament, double conical needle of 26 mm versus 25 mm; RacePack packaging. Verified in catalogue B. Braun |
| Ethicon (J&J MedTech) | PROLENE® 2-0 blue, 90 cm, 1/2 circle conical point | NW844 / 8523H | Comparable by category (not 1:1) | Same material, gauge 2-0 and length; the needle differs (single 30 mm or SH 26 mm) versus double HR25 needle. Verified in authorised Ethicon distribution |
| DemeTECH | DemeLENE™ 2/0 blue, double DSH needle 1/2 circle round body of 26 mm, 90 cm | PM1092026C0P | Comparable by category (not 1:1) | Same gauge, colour and length; DSH needle of 26 mm. Verified in official DemeTECH store |
| TAGUM | Polypropylene 2/0 blue, double 1/2 circle tapered needle of 25 mm, 90 cm | TGPP1115ZL | Comparable by category (not 1:1) | Same gauge, colour and double needle configuration of 25 mm; verify needle finish and packaging in the manufacturer’s data sheet |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the Premisut line versus other brands. Before substituting in tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical versus trocar), needle size, material (pure polypropylene versus copolymer) and the regulatory classification (CE/MDR) of the actual product of each manufacturer. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
- Tapered point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and tapered point minimise tissue trauma. For tissues with some fibrosis or resistance (vascular adventitia, fascia), consider the trocar point (tapercut) variant AMP733HRT2520-2.
- USP gauge 2/0: offers balanced strength and handling for general, vascular and soft tissue surgery. For finer gauges, the 3/0 (AMP733HR2530-2) and 4/0 (AMP733HR2540-2) are available on the same 2xHR25 needle.
- Double thread format 2×90 cm: designed for high-consumption surgeries, continuous sutures and anastomoses with two armed ends, with twice the useful length per unit without rethreading. If you prefer a single 90 cm thread, choose the AMP733HR2520-2 variant.
- Other variants of interest: VisiBlack needle with maximum visibility (AMP733HR2520-2VB), shorter 2xHR20 needle (AMP733HR2020-2) or longer-reach HR30 needle from the same Prime range.
- Verification and storage: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HR2520.2-2 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.