Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME that Cahnos makes available to surgical services, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a double needle, ½ circle, taper point (Taperpoint) of 25 mm in VisiBlack technology (black needle), USP 3/0 gauge and blue thread of 90 cm: a versatile and highly visible configuration, widely used in soft tissue approximation, ligatures and cardiovascular, ophthalmology, vascular and neurosurgery procedures.
It is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and presentation to public tenders. Available under the factory reference P733HR2530-2VB (SKU Cahnos AMP733HR2530-2VB), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (propylene polymer) that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The ½ circular needle with taper point (Taperpoint) and cylindrical body penetrates soft and lax tissues by separating the fibres without cutting them, making it especially suitable for vascular, cardiovascular tissue and delicate structures. The VisiBlack technology incorporates a black needle that dramatically improves its contrast against the surgical field, even in environments with high lighting or bleeding, facilitating visualisation of the tip and the penetration path. The double needle format (2×HR25) allows continuous suture techniques and anastomosis with two armed ends without re-threading, optimising surgical time. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, smooth surface (non-grooved) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 3/0 (metric 2); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Blue (high visibility) |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taper point (Taperpoint), cylindrical body |
| Needle size | 25 mm (HR 25 Prime profile) × 2 needles |
| Configuration | Double needle (2 × HR25) |
| Needle technology | VisiBlack – high-visibility black needle |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, vascular and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P733HR2530-2VB |
| Reference Cahnos (SKU) | AMP733HR2530-2VB |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 3/0 | 2 | 0.200 – 0.249 mm (non-absorbable suture) |
Variants of the Premisut Prime family – polypropylene 1/2 circle taper point, USP 3/0, blue:
| Configuration | Cahnos / factory reference | Observations |
|---|---|---|
| 2×HR25 – 90 cm, black needle VisiBlack | AMP733HR2530-2VB (P733HR2530-2VB) | Product of this data sheet |
| 2×HR25 – 90 cm, standard needle | AMP733HR2530-2 (P733HR2530-2) | Same product; needle without VisiBlack finish |
| 2×HR16 – 90 cm | AMP733HR1630-2 (P733HR1630-2) | HR16 needle of 16 mm for more superficial fields |
| 1×HR30 – 75 cm | AMP732HR3030 (P732HR3030) | Single HR30 needle of 30 mm and thread of 75 cm |
| 2×HRT30 – 90 cm (trocar point) | AMP733HRT3030-2 (P733HRT3030-2) | Trocar point Tapercut for tissues with greater resistance |
| 2×HR35 – 2×75 cm | AMP732HR3530.2 (P732HR3530.2) | Corrugated needle RHR35 of 35 mm and double thread of 75 cm |
4. Equivalences and Cross-References
The reference P733HR2530-2VB corresponds to the official nomenclature of the Premisut Prime range (profile 2×HR25, double needle of 25 mm with VisiBlack technology, USP 3/0 gauge and blue thread of 90 cm). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene Prime – 1/2 circle taper point 2×HR25, 3/0, blue, 90 cm (standard needle) | AMP733HR2530-2 (P733HR2530-2) | Direct range equivalent | Same material, gauge, colour, HR25 needle and length; only the VisiBlack finish (black needle) of this reference varies |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 3/0, 90 cm, double needle CC-30 | W8849 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: material, gauge, colour and 90 cm match; CC-30 TAPERCUT needle (trocar point) of 31 mm versus taper point HR25 of 25 mm. Confirm CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 3/0 (2), 90 cm, 2×HR26 | C2090908 | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue: same material, gauge, colour and double taper point needle; HR26 needle of 26 mm versus HR25 of 25 mm. Confirm exact geometry and profile in official catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, blue, 3/0, taper point | VP558X | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution with CV-23 taper point needle; copolymer material (not pure polypropylene) and needle of shorter length than HR25. Confirm exact profile by IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Pending confirmation (3/0, 90 cm, 2×HR25) | Comparable by category, not verified | Same base material; confirm code, needle geometry and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P733HR2530-2VB with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the taper point needle (Taperpoint) with cylindrical body is the choice for soft, lax and vascular tissues, as it separates the fibres without cutting them (optimal in cardiovascular and vascular surgery). If the protocol requires crossing more fibrous tissues or calcified adventitia, consider the trocar point Tapercut variant of the same range (AMP733HRT3030-2).
Needle size: the 25 mm HR25 offers an excellent balance between control and penetration in medium-depth fields and standard approaches. For more superficial or reduced fields, the double HR16 needle (AMP733HR1630-2) is available; for deeper planes, consider the HR30 (AMP732HR3030) or HR35 (AMP732HR3530.2) profiles from the same Premisut Prime family.
Double-needle format: the 2×HR25 presentation allows continuous suture and anastomosis techniques with two armed ends without re-threading, optimising surgical time and material consumption.
Gauge: USP 3/0 (metric 2) is highly versatile for soft, vascular and cardiovascular tissue. For higher mechanical demands, the same family is available in USP 2/0 and, for delicate tissues or microsurgery, in sizes 4/0, 5/0 and 6/0 within the Premisut Prime catalogue.
VisiBlack technology: the black needle of this reference offers superior contrast against the surgical field, reducing needle localisation time and improving precision in deep planes or under intense lighting; it is the recommended choice when needle visibility is critical.
Sterility verification: product sterilised by ethylene oxide and for single-use; check the blister integrity and expiry date before each use and keep the reference P733HR2530-2VB and batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.