Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP size 0, with a half circle needle with a 30 mm grooved taper point (HR30 Prime profile) and double blue thread of 75 cm (2×75 cm), is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
Supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and submission to public tenders. Available at Cahnos under factory reference P732HR3010.2 (SKU AMP732HR3010.2), maintained without alteration.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, (C3H6)n) presented as an uncoated monofilament, dyed blue for maximum visibility in the surgical field. As it lacks interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia sizes, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The HR30 Prime needle (half circle, cylindrical body and 30 mm grooved taper point) separates and displaces tissue fibres without cutting them, making it suitable for soft, vascular and non-distensible flat tissues requiring controlled penetration and minimal trauma. The grooved finish of the needle body improves grip in the needle holder and facilitates smooth and consistent delivery during knot tying. The double thread presentation (2×75 cm) allows continuous suture and anastomosis techniques with two armed ends without re-threading. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut – Prime quality (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin) |
| Thread structure | Monofilament, needle with grooved body (HR30 Prime profile) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Number of threads | 2 threads per pack |
| Thread length | 2 × 75 cm (two threads of 75 cm) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved |
| Needle size | 30 mm (HR30 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3010.2 |
| Reference Cahnos (SKU) | AMP732HR3010.2 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
Variants of the HR30 Prime family (½ circle, Taperpoint conical point, 30 mm needle):
| Needle profile | USP size | Presentation | Reference |
| HR30 Prime | 0 | 2 × 75 cm | P732HR3010.2 / AMP732HR3010.2 (this product) |
| HR30 Prime | 0 | 1 × 75 cm | P732HR3010 / AMP732HR3010 |
| HR30 Prime | 3/0 | 2 × 75 cm | P732HR3030.2 / AMP732HR3030.2 |
| HR30 Prime | 2/0 | 2 × 75 cm | P732HR3020.2 / AMP732HR3020.2 |
| HR30 (standard) | 0 | 1 × 75 cm | 732HR3010 / AM732HR3010 |
| 2×HR30 Prime | 2/0 | 2 × 90 cm | P733HR3020-2 / AMP733HR3020-2 |
| 2×HR30 Prime | 3/0 | 2 × 90 cm | P733HR3030-2 / AMP733HR3030-2 |
4. Equivalences and Cross-References
Reference P732HR3010.2 corresponds to the official nomenclature of the Premisut Prime range (grooved HR30 Prime profile, double 75 cm thread, USP size 0, blue), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene HR30 Prime, USP 0, blue, 1 × 75 cm | P732HR3010 / AMP732HR3010 | Configuration equivalent within the same system | Same grooved HR30 needle and USP 0 gauge; the presentation changes to a single thread |
| Cahnos (Premisut standard) | Polypropylene HR30, USP 0, blue, 1 × 75 cm | 732HR3010 / AM732HR3010 | Direct equivalent within the same family | Same dimensions and material; standard quality needle versus Prime |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0 | NW846 (blue, 90 cm, ½ circle taper point RB needle, 30 mm) | Comparable by category (not interchangeable 1:1) | Same material, gauge and colour; thread length (90 cm) and single-needle presentation differ |
| Medtronic (Covidien) | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, ½ circle conical point | CP-424 (USP 0, blue, 75 cm, GS-21 needle, 37 mm) | Comparable by category (not interchangeable 1:1) | Same gauge and conical point; copolymer material and 37 mm needle versus 30 mm; verify in official catalogue |
| B. Braun | Premilene® / Optilene® / Dafilon® – blue polypropylene monofilament | C2090 / C3090 series (HR30 USP 0 2×75 cm configuration pending confirmation) | Pending confirmation | Sector family with the same clinical indication; confirm needle geometry and length and presentation in the official B. Braun catalogue. |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical taper point needle | 37020 (USP 0, 37 mm needle, 1 × 75 cm) | Comparable by category (not interchangeable 1:1) | Matches material, size, colour and length (75 cm); cylindrical taper needle of 37 mm, non-grooved, and single thread presentation. |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene®/Optilene® or Laboratorio Aragó are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department at Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR30 needle with grooved Taperpoint conical point is indicated for soft, vascular and non-distensible flat tissues requiring non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar (HRT) or triangular point profiles from the same Premisut Prime range.
Needle size: the 30 mm HR is ideal for medium-depth fields. If a shorter needle is required, the HR 25 (ref. AMP732HR2510) or HR 17 is available; for wider planes, the HR 35 (ref. AMP732HR3510.2) or HR 40 (ref. AMP732HR4010.2), all in USP 0 and double thread presentation.
Size: USP 0 (metric 3.5) offers a very balanced tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR30 Prime family offers 3/0 (ref. AMP732HR3030.2) or 2/0 (ref. AMP732HR3020.2); for greater strength, USP 1 (ref. AMP732HR3001H) with the same needle.
Presentation: the double thread 2×75 cm version optimises usage per procedure and reduces opening of packages; if you prefer one opening per use, consider the single thread version P732HR3010 (SKU AMP732HR3010) or the standard alternative without the Prime range AM732HR3010. For greater thread length, versions 2×90 cm from series 733 are available (ref. AMP733HR3020-2 and AMP733HR3030-2).
Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish (superior penetration); useful when the protocol requires premium quality on delicate tissues. Always verify USP size, colour, thread length and needle size before ordering; keep reference P732HR3010.2 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.





Reviews