Description
1. Product Presentation
The Premisut Prime polypropylene suture is the reliable choice for closure and approximation of soft tissues in high-demand procedures. This reference in USP 2/0 gauge, with double ½ circular needle with conical point (Taperpoint) of 30 mm and blue grooved strand of 90 cm, combines an uncoated monofilament with the Prime needle finish: grooved body, excellent initial and repeated penetration, and minimal tissue reaction.
It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units with individual envelopes and batch traceability, facilitating hospital stock management and presentation for tenders. Available at Cahnos with the factory reference P733HR3020-2 (SKU AMP733HR3020-2), kept unchanged.
2. Technical explanation
Polypropylene is a linear synthetic polymer (polyolefin) extruded in the form of uncoated monofilament. As it is non-absorbable, the thread is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ½ circular needle with cylindrical body and conical Taperpoint tip (HR30 profile) passes through tissues by separating fibres without cutting them, making it ideal for parenchyma, fatty tissue and thin-walled vascular structures. The double needle format (2xHR30) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The highly visible blue grooved strand facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Brand / line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene (polypropylene) monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with highly visible fluted surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue (fluted) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 30 mm (2 x HR30) |
| Configuration | Double needle (2 x HR30) |
| Manufacturing quality | Prime – enhanced penetration needle |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HR3020-2 |
| Reference Cahnos (SKU) | AMP733HR3020-2 |
3.2. Gauge equivalence according to USP/EP standard (non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 2/0 | 3 | 0.35 – 0.399 mm |
3.3. Premisut family 2xHR30 (½ circle, cylindrical body, conical point) and close variants
| Needle profile | Presentation | Reference |
| 2xHR30 (standard) | 2 x 90 cm, USP 2/0 | 733HR3020-2 / AM733HR3020-2 |
| 2xHR30 (Prime) | 90 cm, USP 2/0 (product analysed) | P733HR3020-2 / AMP733HR3020-2 |
| 2xHR30 (Prime) | 2 x 90 cm, USP 2/0 (double thread) | P733HR3020.2 / AMP733HR3020.2-2 |
| 2xHR30 Prime | 90 cm, USP 3/0 | P733HR3030-2 / AMP733HR3030-2 |
| 2xHR30 (standard) | 90 cm, USP 3/0 | 733HR3030-2 / AM733HR3030-2 |
| 2xHRT30 (standard, trocar point) | 90 cm, USP 2/0 | 733HRT3020-2 / AM733HRT3020-2 |
| HR30 (standard, single needle) | 75 cm, USP 2/0 | 732HR3020 / AM732HR3020 |
4. Equivalences and Cross-References
The reference P733HR3020-2 corresponds to the official nomenclature of the Premisut Prime range (2xHR30 profile, double needle, USP 2/0 gauge, blue 90 cm thread). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons between brands are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | P733HR3020-2 / AMP733HR3020-2 | Exact reference equivalence | Official reference of the analysed product |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | 733HR3020-2 / AM733HR3020-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime versus standard) |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 2×90 cm | P733HR3020.2 / AMP733HR3020.2-2 | Configuration equivalent (same system) | Same system and gauge; presentation with double 90 cm thread |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 90 cm, ½ circle needle with round body of 30 mm | NW844 (verified in Ethicon catalogue and authorised distribution; box of 12 units) | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, needle size (30 mm) and length; presentation with single needle versus double needle. Confirm IFU |
| B. Braun | Premilene® – blue polypropylene monofilament, USP 2/0, 75 cm, HR30 Easyslide needle ½ circle conical point | C2090047 (verified in B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | Matches in conical HR30 needle and gauge; length of 75 cm versus 90 cm |
| B. Braun | Optilene® – blue monofilament of polypropylene/polyethylene, USP 2/0, 90 cm, double needle 2xHR30 Easyslide ½ circle | C3090002 (verified in catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | Matches gauge, colour, double HR30 needle and 90 cm length; copolymer composition (not pure polypropylene); Racepack presentation. Confirm IFU and CE/MDR traceability |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 2/0, 90 cm (36 inches) | VP977 (verified in authorised distribution; box of 36 units) | Comparable by category (not interchangeable 1:1) | Copolymer material (polypropylene with polyethylene); tapercutting KV-7 needle with trocar point versus conical point; pack of 36 units |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the Premisut line versus other brands. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. If the tissue presents some fibrosis or resistance, consider the trocar point variant of the same family (ref. AM733HRT3020-2).
USP 2/0 gauge: offers an excellent balance between strength and manageability, widely used in cardiovascular, vascular and soft tissue surgery under moderate tension. For finer tissues, the 3/0 with the same needle is available (AMP733HR3030-2).
Needle length: the 30 mm HR is ideal for medium-depth fields and medium-thickness tissue; for more superficial planes consider the 20 or 25 mm HR from the range, and for bulky tissues the 35 mm HR.
Double needle 2xHR30: designed for continuous sutures and anastomosis with two armed ends, without re-threading; if you prefer a single 75 cm thread with a single needle, choose the AM732HR3020 variant. If you need two 90 cm threads per unit, AMP733HR3020.2-2 is available.
Prime Range: the Premisut Prime line maintains the same needle geometry with a premium finish (improved sharpness and penetration). Always verify the full reference (needle 2xHR30, USP gauge 2/0 and length 90 cm) on the packaging, as well as the integrity of the blister and the expiry date before each use. Single-use product, not re-sterilisable; store below 30 °C, away from moisture and direct sunlight.





Reviews
There are no reviews yet.