Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture in double-needle configuration is the choice of the professional seeking a non-absorbable, durable closure with minimal tissue reaction in highly demanding procedures. Manufactured in high-purity polypropylene monofilament, uncoated, it combines smooth and consistent sliding with excellent handling, reducing surgical trauma and the wicking effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile, single-use and with full batch traceability. Factory reference P736HR1070-2 (SKU Cahnos AMP736HR1070-2), box of 12 units in individual pouches.
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertness which, in monofilament form, behaves as an inert thread with a smooth surface: it exhibits no wicking effect, is not degraded by hydrolysis or tissue enzymes and becomes gradually encapsulated in the tissue, maintaining wound support for more than three months thanks to its high sustained tensile strength. Its low memory and stable knot facilitate reliable approximation of soft tissues.
The ½ circular needle with cylindrical body and conical point (taperpoint, HR profile) of 10 mm is designed to pass through soft tissues and fine vascular structures by separating the fibres without cutting them, minimising bleeding and tissue damage. The double-needle configuration (two needles mounted on the same 60 cm strand) optimises material use and facilitates continuous suture techniques and anastomosis without rethreading, reducing handling times and risk of contamination. The USP 7/0 gauge (metric 0.5) is ideal for microsurgery, fine vascular anastomoses and precision ligatures. Single-use product, sterilised by ethylene oxide (EtO); not suitable for re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P736HR1070-2 |
| SKU Cahnos | AMP736HR1070-2 |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament (isotactic polymer), uncoated, dyed blue |
| Thread structure | Monofilament, grooved (factory designation: grooved blue) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric 0.5) |
| Thread diameter | 0.050 – 0.069 mm (indicative according to USP Pharmacopoeia) |
| Thread length | 60 cm (double needle on the same strand) |
| Thread colour | Identification blue (high visibility) |
| Number of needles | 2 (double needle) |
| Needle curvature | ½ circle (1/2), cylindrical body |
| Tip type | Conical point (taperpoint) |
| Needle size | 2 × HR 10 mm (Prime quality) |
| Sterilisation | Ethylene oxide (EtO), sterile, single-use |
| Commercial presentation | Box of 12 units in individual sachets; batch traceability |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
|---|---|
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
3.3. Premisut Prime HR10 family (1/2 circle, conical point 10 mm) and range variants
| Needle profile | Presentation | Reference Cahnos |
|---|---|---|
| 2 × HR 10 mm Prime (this product) | 2 × 60 cm, USP 7/0, blue | AMP736HR1070-2 |
| 2 × HR 10 mm Prime | 2 × 60 cm, USP 5/0, blue | P736HR1050-2 |
| 2 × HR 8 mm Prime | 2 × 60 cm, USP 7/0, blue | AMP736HR870-2 |
| HR 10 mm Prime (single needle) | 1 × 45 cm, USP 7/0, blue | AMP731HR1070 |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the manufacturer of PREMISUT cross-referencing this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue, USP 7/0 gauge, 60 cm strand and conical-point needle in a ½ circle arc), not interchangeable 1:1. Before substitution in a tender or in closed clinical protocols, the needle type and size, the number of needles and the presentation must be verified in each brand’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT PRIME (Cahnos) | Polypropylene 1/2 circle conical point 2×HR10 Prime, USP 7/0, blue, 60 cm | P736HR1070-2 / AMP736HR1070-2 | Original reference | Double needle ½ conical 10 mm, USP 7/0, blue, 60 cm, box of 12 units |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle RB-3 taper point 1/2 circle 11 mm, 24″ (60 cm) | 8206H | Comparable by category, very close, not interchangeable 1:1 | Code verified in official Ethicon catalogue and authorised distribution: material, gauge, colour, double needle, 1/2 circle radius, conical point and 60 cm length match; difference: 11 mm needle versus 10 mm and pack of 36 units. Confirm CE/MDR traceability against IFU. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle BV175-8 (BV-1) taper point 3/8 circle 9.3 mm EVERPOINT, 24″ (60 cm) | 8747H / EP8747H | Comparable by category, not interchangeable 1:1 | Code verified in official Ethicon catalogue: material, gauge, colour, double needle and 60 cm length match; differences: 3/8 circle radius and 9.3 mm needle (versus 1/2 circle and 10 mm). Pack of 36 units. |
| B. Braun (Aesculap) | PREMILENE® – blue polypropylene monofilament, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | C2090714 (GUDID 04046963691356) | Functional category equivalence (very close) | Reference verified in GUDID/FDA and Aesculap catalogue: material, gauge, colour, double 10 mm needle (DR10) and 60 cm length match; confirm arc geometry (DR10 versus HR10) in the technical data sheet before substitution. |
| B. Braun (Aesculap) | OPTILENE® – blue polypropylene/polyethylene copolymer, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | G3090714 | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: same gauge, colour, double needle and length; copolymer material (not pure polypropylene) with slightly different handling properties. |
| Medtronic (Covidien) | SURGIPRO™ II – blue polypropylene/polyethylene copolymer, 7-0, double needle CVL 3/8 circle taper point, 2×24″ (60 cm) | VP652MX | Comparable by category, not interchangeable 1:1 | Code verified in authorised Covidien/Medtronic distribution: gauge, colour, double needle and 60 cm match; differences: copolymer material, 3/8 circle radius and CVL needle versus HR10. Verify IFU and MDR classification. |
Mandatory technical note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer for this reference; consult the Cahnos technical department before use in a tender.
5. Selection tips and variants of interest
Tissue to be sutured: USP 7/0 gauge (metric 0.5) is the microsurgery choice for very delicate planes, fine skin and small-calibre vascular anastomoses. The conical point (taperpoint) is indicated in soft, slightly fibrous tissues; if you need to pass through denser tissues, consider the trocar-point (tapercut) version of the same Premisut family.
Family variants in the Cahnos catalogue: for the same HR10 needle in 5/0 gauge, P736HR1050-2 is available; if you prefer a shorter 8 mm needle, reference AMP736HR870-2 (2×HR8, 7/0, 60 cm); and for a single HR10 needle in 7/0 with 45 cm thread, AMP731HR1070. Unifying the supplier across the entire permanent suture portfolio enables B2B volume conditions.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P736HR1070-2 and batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.