Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture in double-needle configuration is the choice of the professional seeking a non-absorbable, durable closure with minimal tissue reaction in highly demanding procedures. Manufactured in high-purity, uncoated polypropylene monofilament, it combines smooth, consistent sliding with excellent handling, reducing surgical trauma and the wick effect.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile, single-use and with full batch traceability. Factory reference P731HR6,570-2 (SKU Cahnos AMP731HR6,570-2), box of 12 units in individual pouches.
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertness which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wick effect, is not degraded by hydrolysis or tissue enzymes and gradually becomes encapsulated in the tissue, maintaining wound support for more than three months thanks to its high sustained tensile strength. Its low memory and stable knot facilitate reliable approximation of soft tissues.
The ½ circular needle with cylindrical body and taper point (HR profile, taperpoint) of 6.5 mm is designed to pass through soft tissues and very fine vascular structures by separating the fibres without cutting them, minimising bleeding and tissue damage: it is a reference geometry in microsurgery, ophthalmology and cardiovascular surgery. The double-needle configuration (two needles mounted on the same 45 cm strand) optimises material use and facilitates continuous suture and anastomosis techniques without rethreading, reducing handling times and contamination risk. The USP 7/0 gauge (metric 0.5) is ideal for microsurgery, delicate planes, fine vascular anastomoses and precision ligatures. Single-use product, sterilised by ethylene oxide (EO); not suitable for re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer reference | P731HR6,570-2 |
| SKU Cahnos | AMP731HR6,570-2 |
| Brand / Quality | PREMISUT PRIME (premium range) |
| Thread material | Polypropylene monofilament (isotactic polymer), uncoated, dyed blue (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Monofilament, with grooved surface (factory designation: grooved blue) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (EP metric 0.5); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 45 cm (double needle on the same strand) |
| Thread colour | Grooved blue with high visibility in the surgical field |
| Number of needles | 2 (double-needle configuration) |
| Needle curvature | ½ circle (1/2), cylindrical body |
| Tip type | Taperpoint conical point |
| Needle size | 2 × HR 6.5 mm (Prime quality) |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use, not re-sterilisable |
| Commercial presentation | Box of 12 units in individual sachets; batch traceability |
| Indications | Approximation of soft tissues, surgical ligatures, microsurgery, cardiovascular surgery, ophthalmology and neurosurgery |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 7/0 | 0.5 | 0.050 – 0.069 mm |
3.3. PREMISUT PRIME HR 6.5 family (½ circle, 6.5 mm Taperpoint taper point) and range variants
| Needle profile | USP size | Presentation | Reference Cahnos |
|---|---|---|---|
| 2 × HR 6.5 mm Prime (this product) | 7/0 | 2 × 45 cm, blue, double needle | AMP731HR6,570-2 |
| 2 × HR 6.5 mm Prime | 6/0 | 2 × 45 cm, blue, double needle | AMP731HR6,560-2 |
| 2 × HR 6.5 mm Prime | 6/0 | 2 × 60 cm, blue, double needle | AMP736HR6,560-2 |
| 2 × HR 8 mm Prime | 7/0 | 2 × 60 cm, blue, double needle | AMP736HR870-2 |
| 2 × HR 10 mm Prime | 7/0 | 2 × 60 cm, blue, double needle | AMP736HR1070-2 |
| HR 10 mm Prime (single needle) | 7/0 | 1 × 45 cm, blue | AMP731HR1070 |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the PREMISUT manufacturer cross-referencing this product with other brands. The references listed below are considered comparable at category level (non-absorbable polypropylene monofilament suture, blue, USP 7/0 gauge and double taper-point needle in an arc), not interchangeable 1:1. Before substitution in a tender or in closed clinical protocols, the needle size and number, strand length and presentation must be verified in each brand’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT PRIME (Cahnos) | Polypropylene 1/2 circle taper point 2×HR6.5 Prime, USP 7/0, blue, 45 cm | P731HR6,570-2 / AMP731HR6,570-2 | Original reference | Double needle ½ circle taper point 6.5 mm, USP 7/0, grooved blue, 45 cm, box of 12 units |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double RB-3 taper point needle, ½ circle, 11 mm, 24″ (60 cm) | 8206H | Comparable by category, very close, not interchangeable 1:1 | Code verified in official Ethicon catalogue and authorised distribution: material, gauge, colour, double needle, ½ circle radius and taper point match; differences: 11 mm needle versus 6.5 mm and 60 cm strand versus 45 cm; pack of 36 units. Confirm CE/MDR traceability against IFU. |
| B. Braun (Aesculap) | PREMILENE® – blue polypropylene monofilament, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | C2090714 (GUDID 04046963691356) | Functional category equivalence (very close) | Reference verified in GUDID/FDA and Aesculap catalogue: material, gauge, colour and 10 mm double needle (DR10) match; differences: 10 mm needle versus 6.5 mm and 60 cm strand; confirm arc geometry in the technical data sheet before substitution. |
| B. Braun (Aesculap) | OPTILENE® – blue polypropylene/polyethylene copolymer, 7/0 (0.5), double needle 2×DR10 CV RCP, 60 cm | G3090714 | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: same gauge, colour, double needle and length; copolymer material (not pure polypropylene) with slightly different handling properties. |
| Medtronic (Covidien) | SURGIPRO™ II – blue polypropylene/polyethylene copolymer, 7-0, double CVL taper point needle, ⅜ circle, 2×24″ (60 cm) | VP652MX | Comparable by category, not interchangeable 1:1 | Code verified in authorised Covidien/Medtronic distribution: gauge, colour, double needle and 60 cm match; differences: copolymer material, ⅜ circle radius and CVL needle versus HR6.5. Verify IFU and MDR classification. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle BV175-8 conical point ⅜ circle 9.3 mm, 24″ (60 cm) | 8747H / EP8747H | Comparable by category, not interchangeable 1:1 | Code verified in official Ethicon catalogue: material, gauge, colour, double needle and 60 cm length match; differences: ⅜ circle radius and 9.3 mm needle versus ½ circle and 6.5 mm. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, 7/0 (0.5), double needle HR-12 conical point, 0.75 m | CP05340C | Comparable by category, not interchangeable 1:1 | Code verified in the official Serag-Wiessner supply programme (2019): same material, gauge and double conical needle; HR-12 needle and 75 cm thread versus 6.5 mm and 45 cm. Confirm CE marking and traceability. |
| Vitrex Medical (Chiralen) | Chiralen – blue polypropylene monofilament, double needle 7/0 | PP590224 (pending confirmation) | Not verified | Family and material confirmed in Vitrex Medical catalogue; the specific 7/0 · double conical needle code could not be verified against an official source during this consultation. Confirm with the manufacturer before use. |
Mandatory technical note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before use in tenders. This needle geometry (2×HR 6.5, USP 7/0, 45 cm, conical point) is only fully safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
- Tissue to suture: USP 7/0 (metric 0.5) gauge is the microsurgery choice for very delicate planes, thin skin and small-calibre vascular anastomoses; the conical point is indicated for soft, poorly fibrous and well-irrigated tissues. If you need to penetrate denser tissues, consider the trocar point version of the same PREMISUT family.
- Family variants in the Cahnos catalogue: for the same HR 6.5 needle in gauge 6/0 you have AMP731HR6,560-2 (45 cm) and AMP736HR6,560-2 (60 cm); if you prefer a slightly larger needle, references AMP736HR870-2 (2×HR 8, 7/0, 60 cm) or AMP736HR1070-2 (2×HR 10, 7/0, 60 cm); and for a single HR 10 needle in 7/0 with 45 cm thread, the AMP731HR1070. Unifying the supplier across the entire permanent suture portfolio enables volume B2B conditions.
- Presentation: the double needle version reduces packaging openings per procedure and facilitates continuous sutures and bilateral techniques without rethreading, maximising the use of the 45 cm thread.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P731HR6,570-2 and the batch number for traceability in the operating theatre.
- For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.