Description
1. Introduction
The polypropylene suture PREMISUT is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates double ½ circular needle with conical point (Taperpoint) of 30 mm (2xHR30 profile), USP 2/0 gauge and blue thread of 90 cm, a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile and ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos with the factory reference 733HR3020-2 (SKU AM733HR3020-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it suitable for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The double needle (2x) format allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The high-visibility grooved blue thread facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (high-visibility grooved surface) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue (grooved) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint, HR profile |
| Needle size | 30 mm (2xHR30) |
| Configuration | Double needle (2 × HR30) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 733HR3020-2 |
| Reference Cahnos (SKU) | AM733HR3020-2 |
3.2. PREMISUT family 2xHR30 (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHR 30 (standard) | 2 x 90 cm, USP 2/0 (analysed product) | 733HR3020-2 / AM733HR3020-2 |
| 2xHR 30 (Prime) | 2 x 90 cm, USP 2/0 | P733HR3020-2 / AMP733HR3020-2 |
| 2xHR 30 (standard) | 2 x 90 cm, USP 3/0 | 733HR3030-2 / AM733HR3030-2 |
| HR 30 (standard, single needle) | 1 x 75 cm, USP 2/0 | 732HR3020 / AM732HR3020 |
| 2xHR 20 (standard) | 2 x 90 cm, USP 2/0 | 733HR2020-2 / AM733HR2020-2 |
| 2xHRT 30 (standard, trocar point) | 2 x 90 cm, USP 2/0 | 733HRT3020-2 / AM733HRT3020-2 |
4. Equivalences and Cross-References
The reference 733HR3020-2 corresponds to the official nomenclature of the PREMISUT range (2xHR30 profile, double needle conical point, USP 2/0 gauge, blue thread of 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
|---|---|---|---|---|
| PREMISUT (Cahnos) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | 733HR3020-2 / AM733HR3020-2 | Exact reference equivalence (current product) | Official reference of the analysed product |
| PREMISUT Prime (Cahnos) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | P733HR3020-2 / AMP733HR3020-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime version) |
| PREMISUT (Cahnos) | Polypropylene 1/2 circle 2xHR30, USP 3/0, blue, 90 cm | 733HR3030-2 / AM733HR3030-2 | Configuration equivalent (same system) | Same 2xHR30 needle and length; the gauge changes to USP 3/0 |
| B. Braun | Optilene® – blue polypropylene monofilament, USP 2/0 (metric 3), 90 cm, double needle 2xHR30 Easyslide ½ circle | C3090002 (verified in catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and HR30 needle size; Racepack packaging system; validate IFU and CE/MDR traceability |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 90 cm, double needle CC-30 TAPERCUT ½ circle of 31 mm | W8850 (verified in authorised distribution; box of 12 units) | Comparable by category (not interchangeable 1:1) | Double needle and length match; trocar point (Tapercut) versus conical point (Taperpoint) and 31 mm needle versus 30 mm |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 2/0, 90 cm (36 inches) | VP977 (verified in authorised distribution; box of 36 units) | Comparable by category (not interchangeable 1:1) | Copolymer material (polypropylene with polyethylene, not pure polypropylene); tapercutting KV-7 needle with trocar point versus conical point; packaging of 36 units |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 2/0, 75 cm, HR30 Easyslide needle ½ circle conical point | C2090047 (verified in B. Braun catalogue; 75 cm variant) | Pending confirmation for 2×90 cm | 75 cm variant with conical HR30 needle confirmed; code for double needle 2×90 cm USP 2/0 pending validation with the manufacturer |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the PREMISUT line against other brands. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
- Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. If the tissue shows some fibrosis or resistance (vascular adventitia, fascia), consider the trocar-point variant from the same family (ref. AM733HRT3020-2).
- USP 2/0 gauge: offers an excellent balance between strength and manageability, widely used in cardiovascular, vascular and soft tissue surgery under moderate tension. For finer tissues, the 3/0 is available on the same needle (AM733HR3030-2).
- Needle length: the 30 mm HR is ideal for deep fields and medium-thickness tissue; for more superficial planes consider the 20 mm HR (AM733HR2020-2) and for bulky tissue the 35 mm HR from the range.
- Double needle 2×90 cm: designed for continuous sutures and anastomoses with two armed ends, without re-threading; if you prefer a single 75 cm thread with a single needle, choose the AM732HR3020 variant.
- Prime range: the PREMISUT Prime line (AMP733HR3020-2) maintains the same needle geometry with a premium finish (improved sharpness and penetration); useful when the protocol demands superior quality in delicate tissues.
- Prior verification: always confirm the full reference (2xHR30 needle, USP 2/0 gauge and 90 cm length) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable.





Reviews