Description
1. Commercial Introduction
The polypropylene suture PREMISUT is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable performance, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 2/0, with a ½ circle needle with 30 mm grooved conical point (HR30 profile) and 75 cm blue thread, is the classic option for soft tissue approximation, ligatures and high-demand procedures: cardiovascular surgery, ophthalmology and neurosurgery.
It is supplied sterile and ready for single use in a box of 12 units with batch traceability, which facilitates hospital stock management and submission to public tenders. Factory reference 732HR3020, marketed by Cahnos as SKU AM732HR3020, keeping the manufacturer’s official nomenclature without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) supplied as an uncoated monofilament, dyed blue for maximum visibility in the surgical field. As it has no interstices and no wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is neither absorbed nor degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The HR30 needle (½ circle, cylindrical body and 30 mm grooved Taperpoint conical point) separates and displaces tissue fibres without cutting them, making it ideal for soft, vascular and poorly distensible tissue planes that require controlled penetration and minimal trauma. The grooved finish of the needle improves grip in the needle holder and facilitates smooth, consistent delivery during knot tying. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | PREMISUT (polypropylene, standard quality) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin) |
| Structure | Monofilament of a single filament, without coating or braiding |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Needle type | Taper point, grooved |
| Needle size | 30 mm (HR30 profile) |
| Manufacturing quality | Standard (PREMISUT range; for premium finish see Prime variant) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732HR3020 |
| Reference Cahnos (SKU) | AM732HR3020 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.349 mm |
Variants of the HR30 family (½ circle, Taperpoint conical point, 30 mm needle):
| Needle profile | USP size | Presentation | Reference |
| HR30 (standard) | 2/0 | 1 × 75 cm | 732HR3020 / AM732HR3020 (this product) |
| HR30 Prime | 2/0 | 1 × 75 cm | P732HR3020 / AMP732HR3020 |
| HR30 Prime | 2/0 | 2 × 75 cm | P732HR3020.2 / AMP732HR3020.2 |
| HR30 (standard) | 0 | 1 × 75 cm | 732HR3010 / AM732HR3010 |
| HR30 (standard) | 3/0 | 1 × 75 cm | 732HR3030 / AM732HR3030 |
| 2×HR30 (standard) | 2/0 | 2 × 90 cm | 733HR3020-2 / AM733HR3020-2 |
4. Equivalences and Cross-References
Reference 732HR3020 corresponds to the official nomenclature of the PREMISUT range (grooved HR30 profile, single 75 cm thread, USP 2/0 gauge, blue colour) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (PREMISUT PRIME) | Polypropylene HR30 Prime, USP 2/0, blue, 75 cm | P732HR3020 / AMP732HR3020 | Direct equivalent within the same family | Same ribbed HR30 needle, gauge, colour and length; the needle finish changes to Prime range (improved penetration). |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 75 cm, CT-1 ½ circle taper point needle | 8423H | Comparable by category (not interchangeable 1:1) | Verified in the official Ethicon catalogue. Material, gauge, colour and length (75 cm) match; the CT-1 needle is 36 mm and non-grooved, compared with the grooved HR30 of 30 mm. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, USP 2/0, 75 cm, CT-2 taper point needle | 8411H | Comparable by category (not interchangeable 1:1) | Verified in official Ethicon catalogue. Same gauge, colour and length; CT-2 needle of 26 mm versus HR30 of 30 mm. |
| B. Braun | Premilene® – blue monofilament polypropylene, USP 2/0, 75 cm, HR30 EasySlide ½ circle conical point needle | C2090047 | Comparable by category (not interchangeable 1:1) | Verified in the official B. Braun catalogue and AccessGUDID. Material, gauge, colour, 30 mm conical HR30 needle and length (75 cm) match; non-grooved needle. Confirm IFU and traceability. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene, blue monofilament, conical point ½ circle | VP843 | Comparable by category (not interchangeable 1:1) | Verified in authorised distribution. Same gauge and conical point; copolymeric material (polypropylene/polyethylene), V-26 needle of 26 mm and 36″ (≈91 cm) strand. |
| DemeTECH | DemeLENE® – blue monofilament polypropylene, USP 2/0, 75 cm, DCT-2 round body ½ circle needle | PM292026B1P | Comparable by category (not interchangeable 1:1) | Verified in the official DemeTECH store. Same gauge, colour and length; DCT-2 needle of 26 mm round body, without grooved channel. |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical conical needle of 30 mm | 37017 (C20, USP 2/0, 1×75 cm) | Comparable by category (not interchangeable 1:1) | Verified in the official Laboratorio Aragó catalogue. Material, gauge, colour, length and 30 mm needle geometry match; non-grooved needle. |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Surgipro™ II, DemeLENE®, Premilene® or Laboratorio Aragó are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Contact the technical department at Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR30 needle with grooved Taperpoint conical point is indicated for soft, vascular and poorly distensible tissue planes requiring non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point profiles (HRT) from the same PREMISUT range.
Needle size: the 30 mm HR is ideal for medium-depth fields. If you require a shorter needle, the HR25 (ref. AM732HR2520) is available; for wider planes, the HR35 (ref. AM732HR3520) in USP 2/0 and 75 cm.
Gauge: USP 2/0 offers an excellent balance between strength and manageability for vascular ligatures and soft tissues. The same HR30 family offers 3/0 (ref. AM732HR3030) for a smaller diameter or USP 0 (ref. AM732HR3010) for greater strength.
Prime range and presentations: the PREMISUT Prime line (ref. AMP732HR3020) maintains the same needle geometry with a premium finish for improved penetration. If you prefer to make the most of each opening with two armed ends, consider the double-thread version 2×75 cm (ref. AMP732HR3020.2) or the double-needle version 2×90 cm from the 733 series (ref. AM733HR3020-2).
Always verify the USP gauge, colour, thread length and needle size and point before placing the order; keep reference 732HR3020 and the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use; store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews