Description
1. Commercial Introduction
The polypropylene suture Premisut Prime VisiBlack that Cahnos makes available to surgical departments, purchasing centres and tenders is the reference solution when a non-absorbable suture with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a double ½-circle needle with conical point (taperpoint) of 20 mm in VisiBlack technology (black needle), USP 5/0 gauge and blue strand of 90 cm: a high-visibility configuration, widely used in soft tissue approximation, ligatures and cardiovascular, ophthalmology, vascular and neurosurgery procedures.
It is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and submission to public tenders. Available under the factory reference P733HR2050-2VB (SKU Cahnos AMP733HR2050-2VB), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (propylene polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ½-circle needle with conical point (taperpoint) and cylindrical body penetrates soft and lax tissues by separating the fibres without cutting them, making it especially suitable for vascular, cardiovascular tissue and delicate structures. The HR20 profile of 20 mm offers excellent control in superficial and medium-thickness surgical fields, with the black VisiBlack needle that dramatically improves contrast on the surgical field, even with intense lighting or bleeding. The double-needle format (2×HR20) allows continuous suture and anastomosis techniques with two armed ends without rethreading, optimising surgical time. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, high-visibility blue grooved |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 5/0 (metric 1); diameter 0.10 – 0.149 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Blue (high visibility) |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Conical point (taperpoint), cylindrical body |
| Needle size | 20 mm (HR20 Prime profile) × 2 needles |
| Configuration | Double needle (2 × HR20) |
| Needle technology | VisiBlack – high-visibility black needle |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, vascular and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P733HR2050-2VB |
| Reference Cahnos (SKU) | AMP733HR2050-2VB |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (non-absorbable suture) |
4. Equivalences and Cross-References
The reference P733HR2050-2VB corresponds to the official nomenclature of the Premisut Prime range (2×HR20 profile, double 20 mm needle with VisiBlack technology, USP 5/0 gauge and blue 90 cm thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene Prime VisiBlack – 1/2 circle taperpoint 2×HR20, 5/0, blue, 90 cm (black needle, current product) | P733HR2050-2VB / AMP733HR2050-2VB | Original reference | Analysed product; factory reference without altering characters |
| Cahnos (Premisut Prime) | Polypropylene Prime – 1/2 circle taperpoint 2×HR20, 5/0, blue, 90 cm (standard needle) | AMP733HR2050-2 (P733HR2050-2) | Direct range equivalent | Same material, gauge, HR20 needle and length; only the VisiBlack finish (black needle) varies |
| Cahnos (Premisut Prime) | 1/2 circle taperpoint 2×HR25, 5/0, blue, 90 cm (black VisiBlack needle) | AMP733HR2550-2VB (P733HR2550-2VB) | Direct range equivalent | Same material, gauge, colour and length; HR25 needle of 25 mm versus HR20 of 20 mm |
| Cahnos (Premisut Prime) | 1/2 circle taperpoint 2×HR16, 5/0, blue, 90 cm (black VisiBlack needle) | AMP733HR1650-2VB (P733HR1650-2VB) | Direct range equivalent | Same material, gauge, colour and length; HR16 needle of 16 mm for smaller fields |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, 90 cm, double RB-1 taperpoint needle of 17 mm | 8556G (2×RB-1, box of 12 units) / 8556H (box of 36 units) | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, length and double taper-point needle match; the RB-1 needle of 17 mm differs from HR20 of 20 mm |
| Ethicon (J&J MedTech) | PROLENE® with VISI-BLACK® needle – 5/0, 90 cm, double RB-1 needle of 17 mm (black needle) | 8356H | Comparable by category, not interchangeable 1:1 | Code verified in the Ethicon product centre: high-visibility black needle of 17 mm (1/2 circle, taper point) versus HR20 of 20 mm; same blue polypropylene base |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 (EP 1), 90 cm, double needle 2×HR26 | C2090905 | Comparable by category, not interchangeable 1:1 | Verified in B. Braun catalogue and device data sheet (AccessGUDID): same material, gauge, colour and double conical needle; HR26 needle of 26 mm versus HR20 of 20 mm; RacePack packaging |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, 5/0 (EP 1), 90 cm, double needle 2×HR26 CV RCP | C3090905 | Comparable by category, not interchangeable 1:1 | Verified in official B. Braun catalogue: same gauge and double-needle configuration; the material differs (copolymer of polypropylene and polyethylene versus pure polypropylene) and the 26 mm needle |
| Serag-Wiessner / DemeTECH | SERAPREN® / DemeLENE™ – blue polypropylene | Pending confirmation for 5/0, 90 cm, 2×HR26/DSH | Comparable by category, not verified | Polypropylene family with similar clinical indication; confirm exact code for 5/0 gauge, geometry and needle size in official catalogue before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P733HR2050-2VB with other brands; comparisons with PROLENE®, Premilene® or Optilene® are functional, at category level, and must be validated against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the conical point (taperpoint) needle with cylindrical body is the choice for soft, lax and vascular tissues, as it separates the fibres without cutting them (optimal in cardiovascular and vascular surgery). If the protocol requires crossing more fibrous tissues or calcified adventitia, consider the trocar point (tapercut) variant from the same range.
- Needle size: the HR20 of 20 mm offers excellent control in superficial and medium-thickness surgical fields. For smaller or paediatric fields, the HR16 (AMP733HR1650-2VB) is available and, for deeper planes, the HR25 (AMP733HR2550-2VB) from the same VisiBlack family in 5/0.
- Double-needle format: the 2×HR20 presentation allows continuous suture and anastomosis techniques with two armed ends without rethreading, optimising surgical time and material consumption.
- Gauge: USP 5/0 (metric 1) is very fine and highly manageable, ideal for ophthalmology, microvascular and delicate soft tissue. For greater mechanical demand, the same VisiBlack family is available in USP 4/0 (AMP733HR2540-2VB), 3/0 (AMP733HR2530-2VB) and 2/0 (AMP733HR2520-2VB).
- VisiBlack technology: the black needle of this reference offers superior contrast on the surgical field, reducing needle localisation time and improving precision in deep planes or with intense lighting; it is the recommended choice when needle visibility is critical.
- Verification and storage: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HR2050-2VB and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews