Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the choice of the professional seeking a non-absorbable, durable closure with minimal tissue reaction in highly demanding procedures. This model combines a high-purity, uncoated, blue-dyed polypropylene monofilament with a ½ circle needle, cylindrical body and 10 mm Taperpoint conical point (HR 10 Prime profile), in USP 7/0 gauge and 45 cm length: a microsurgery configuration designed for very delicate planes.
Designed for B2B supply to hospitals, clinics, operating theatres and purchasing centres, it is supplied sterile, single-use and with full batch traceability. Factory reference P731HR1070 (SKU Cahnos AMP731HR1070), box of 12 units in individual sachets.
2. Technical Explanation
Polypropylene is a synthetic polymer with high chemical inertness which, in monofilament form, behaves as an inert thread with a smooth surface: it has no wicking effect, is not degraded by hydrolysis or tissue enzymes and becomes gradually encapsulated in the tissue, maintaining wound support for more than three months thanks to its high sustained tensile strength. Its low memory and stable knot facilitate reliable approximation of soft tissues.
The ½ circular needle with cylindrical body and conical point (Taperpoint, HR profile) of 10 mm is designed to pass through soft tissues and fine vascular structures by separating the fibres without cutting them, minimising bleeding and tissue damage. USP 7/0 gauge (metric 0.5) is ideal for microsurgery, small-calibre vascular anastomoses and precision ligatures in ophthalmology and neurosurgery. Single-use product, sterilised by ethylene oxide (EtO); does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Manufacturer reference | P731HR1070 |
| SKU Cahnos | AMP731HR1070 |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament (isotactic polymer), uncoated, dyed blue |
| Thread structure | Monofilament, grooved (factory designation: grooved blue) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric 0.5) |
| Thread diameter | 0.050 – 0.069 mm (indicative according to USP Pharmacopoeia) |
| Thread length | 45 cm (single needle, 1 strand per unit) |
| Thread colour | Identification blue (high visibility) |
| Number of needles | 1 (single needle) |
| Needle curvature | ½ circle (1/2), cylindrical body |
| Tip type | Conical point (taperpoint) |
| Needle size | HR 10 mm (Prime quality) |
| Sterilisation | Ethylene oxide (EtO), sterile, single-use |
| Commercial presentation | Box of 12 units in individual sachets; batch traceability |
3.2. Mechanical behaviour and clinical use
| Parameter | Value |
| Tensile strength retention | Maintained for more than 3 months (non-absorbable) |
| Tissue reaction | Minimal (inert material) |
| Sliding | Smooth and consistent |
| Main indications | Approximation of soft tissues, surgical ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
3.3. Premisut Prime HR10 family (1/2 circle, conical point 10 mm) and range variants
| Needle profile | Presentation | Reference Cahnos |
| HR 10 mm Prime (single needle, this product) | 1 × 45 cm, USP 7/0, blue | AMP731HR1070 |
| 2 × HR 10 mm Prime | 2 × 60 cm, USP 7/0, blue | AMP736HR1070-2 |
| 2 × HR 10 mm Prime | 2 × 60 cm, USP 6/0, blue | AMP736HR1060-2 |
| 2 × HR 10 mm Prime | 2 × 60 cm, USP 5/0, blue | AMP736HR1050-2 |
| 2 × HR 8 mm Prime | 2 × 60 cm, USP 7/0, blue | AMP736HR870-2 |
4. Equivalences and Cross-References
Important: there is no official equivalence table validated by the manufacturer of PREMISUT cross-referencing this reference with other brands. The references indicated below are considered comparable at category level (non-absorbable monofilament polypropylene suture, blue colour, USP 7/0 gauge, conical-point needle in a ½ circle arc), not interchangeable 1:1. Before substitution in a tender or in closed clinical protocols, the needle type and size, number of needles and presentation must be verified in each brand’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| PREMISUT PRIME (Cahnos) | Polypropylene ½ circle conical point HR10 Prime, USP 7/0, blue, 45 cm | P731HR1070 / AMP731HR1070 | Original reference | Single needle ½ conical 10 mm, USP 7/0, blue, 45 cm, box of 12 units |
| PREMISUT PRIME (Cahnos) | Polypropylene ½ circle conical point 2×HR10 Prime, USP 7/0, blue, 60 cm | P736HR1070-2 / AMP736HR1070-2 | Direct range equivalent | Same HR10 needle, Prime quality, radius and colour; the presentation changes to double needle and 2 × 60 cm. |
| PREMISUT PRIME (Cahnos) | Polypropylene ½ circle conical point 2×HR10 Prime, USP 6/0, blue, 60 cm | AMP736HR1060-2 | Direct range equivalent | Same HR10 needle and presentation; gauge 6/0 (metric 0.7) versus 7/0. |
| PREMISUT PRIME (Cahnos) | Polypropylene ½ circle conical point 2×HR8 Prime, USP 7/0, blue, 60 cm | AMP736HR870-2 | Direct range equivalent | Identical gauge and quality; HR8 needle of 8 mm versus HR10 of 10 mm, double needle. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, single BV175-7 taper point needle, 45 cm (18″) | M8764 | Comparable by category, not interchangeable 1:1 | Material, gauge, colour, single needle and 45 cm length match; differences: 3/8 circle arc and 8 mm needle versus ½ circle and 10 mm. Code verified in authorised distribution; confirm CE/MDR traceability against the IFU. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, microsurgery double needle TF-6 taper point 6.5 mm, 45 cm | EH7813E | Comparable by category, not interchangeable 1:1 | Material, gauge, colour and 45 cm length match; differences: double-needle configuration with 6.5 mm TF-6 points versus a single HR10 10 mm needle. Code verified in the Ethicon EMEA catalogue and authorised distribution. |
| B. Braun (Aesculap) | PREMILENE® – blue polypropylene monofilament, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | C2090714 (GUDID 04046963691356) | Functional category equivalence (very close) | Reference verified in GUDID/FDA and the Aesculap catalogue: material, gauge and colour match; differences: double 10 mm needle (DR10) and 60 cm versus single 10 mm needle (HR10) and 45 cm. Confirm arc geometry (DR versus HR) in the technical data sheet before substitution. |
| Medtronic (Covidien) | SURGIPRO™ II – blue polypropylene/polyethylene copolymer, 7-0, double needle CVL 3/8 circle taper point, 2×24″ (60 cm) | VP652MX | Comparable by category, not interchangeable 1:1 | Code verified in authorised Covidien/Medtronic distribution: gauge, colour and 60 cm match; differences: copolymer material (not pure polypropylene), 3/8 circle radius, CVL needle and double needle versus single HR10 needle. Verify IFU and MDR classification. |
Mandatory technical note: references from other manufacturers must always be checked against their official source (technical data sheet, IFU, GUDID/FDA or EUDAMED). There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using it in a tender.
5. Selection tips and variants of interest
Tissue to be sutured: USP 7/0 gauge (metric 0.5) is the microsurgery choice for very delicate planes, fine skin and small-calibre vascular anastomoses. The conical point (taperpoint) is indicated for soft, minimally fibrous tissues; if you need to pass through denser tissues, consider the trocar-point (tapercut) version from the same Premisut family.
Family variants in the Cahnos catalogue: for the same HR10 needle, double-needle versions are available in 7/0 (AMP736HR1070-2, 2 × 60 cm), 6/0 (AMP736HR1060-2) and 5/0 (AMP736HR1050-2); if you prefer a shorter 8 mm needle, reference AMP736HR870-2 (2×HR8, 7/0, 60 cm). Unifying supplier across the entire permanent suture portfolio enables B2B volume conditions.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P731HR1070 and batch number for traceability in the operating theatre. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.