Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the reference choice for operating theatres, purchasing departments and tenders seeking a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 0 gauge incorporates a ½ circle needle with cylindrical body and conical point (Taperpoint) of 40 mm (HR 40 Prime profile) and a blue thread of 75 cm: a solid and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues under medium tension.
It is supplied sterile, ready for individual use, in a box of 12 units with individual sachets and batch traceability. It is marketed under the factory reference P732HR4010 (SKU AMP732HR4010), kept without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (isotactic polymer) presented as an uncoated monofilament, dyed blue with phthalocyanine. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR 40 Prime needle (½ circle, cylindrical body with 40 mm taperpoint conical point) penetrates soft and slightly distensible tissues by separating the fibres without cutting them, which reduces tissue trauma and is especially valuable in vascular structures, arterial adventitia and deep planes. The grooved finish of the needle body and the Prime range steel facilitate smooth passage during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. Recommended storage below 30 °C, away from moisture and direct sunlight.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, needle with improved finish) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (phthalocyanine) |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical (Taperpoint), HR profile |
| Needle size | 40 mm (HR 40 Prime profile) |
| Configuration | Single needle (1 × HR 40) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR4010 |
| Reference Cahnos (SKU) | AMP732HR4010 |
Variants of the HR 40 Prime family (½ circle, Taperpoint conical point, 40 mm needle):
| Needle profile | USP size | Presentation | Reference |
| HR 40 Prime | 0 | 1 × 75 cm | P732HR4010 / AMP732HR4010 (this product) |
| HR 40 Prime | 0 | 2 × 75 cm | P732HR4010.2 / AMP732HR4010.2 |
| HR 40 Prime | 1 | 1 × 75 cm | P732HR4001 / AMP732HR4001 |
| HR 40 Prime | 1 | 2 × 75 cm | P732HR4001.2 / AMP732HR4001.2 |
| HR 40 Prime | 2 | 1 × 75 cm | P732HR4002 / AMP732HR4002 |
| HR 40 Prime | 2 | 2 × 75 cm | P732HR4002.2 / AMP732HR4002.2 |
| HR 40 (standard) | 2 | 1 × 75 cm | 732HR4002 / AM732HR4002 |
4. Equivalences and Cross-References
The reference P732HR4010 corresponds to the official nomenclature of the Premisut Prime range (HR 40 Prime profile, single needle, USP 0 gauge, 75 cm thread) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or instructions for use (IFU) before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene HR 40 Prime, USP 0, blue, 1 × 75 cm | P732HR4010 / AMP732HR4010 | Direct product reference | Product analysed in this data sheet |
| Cahnos (Premisut Prime) | Polypropylene HR 40 Prime, USP 0, blue, 2 × 75 cm | P732HR4010.2 / AMP732HR4010.2 | Configuration equivalent within the same system | Same HR 40 needle and USP 0 gauge; presentation changes to double thread |
| Cahnos (Premisut Prime) | Polypropylene HR 40 Prime, USP 1, blue, 1 × 75 cm | P732HR4001 / AMP732HR4001 | Comparable within the same system | Same HR 40 needle and presentation; USP 1 gauge of larger diameter |
| Cahnos (Premisut Prime) | Polypropylene HR 40 Prime, USP 2, blue, 1 × 75 cm | P732HR4002 / AMP732HR4002 | Comparable within the same system | Same HR 40 needle and presentation; USP 2 gauge of larger diameter |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 90 cm, ½ circle taper point needle | NW846 | Comparable by category (not 1:1) | Same blue polypropylene base and gauge; single needle of 30 mm versus HR 40 of 40 mm and thread of 90 cm versus 75 cm; check IFU before substituting |
| Medtronic / Covidien | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, USP 0, 75 cm, GS-21 ½ circle conical point needle 37 mm | CP-424 | Comparable by category (not 1:1) | Same gauge and point type; 37 mm needle versus 40 mm; copolymer material (not pure polypropylene); not interchangeable 1:1 |
| B. Braun | Premilene® / Optilene® – blue polypropylene monofilament, USP 0 (EP 3.5) | Series C2090 / C2095995 (HRC37S) – exact code pending confirmation | Pending confirmation | Same blue polypropylene base and gauge; confirm needle geometry and size (½ circle, conical 40 mm), length and presentation in official catalogue |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Pending confirmation | Sector family with same clinical indication; not interchangeable 1:1 without technical verification |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical (conical) needle 40 mm | 37096 (C30, USP 1, 1 × 100 cm) | Comparable by category | Material, colour and needle geometry match; gauge (USP 1 versus USP 0) and thread length differ |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™, SERAPREN® or Laboratorio Aragó are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the HR needle with Taperpoint conical point is suitable for soft, vascular and slightly distensible planes requiring non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider triangular point profiles (reverse cutting) from the same Premisut Prime range.
- Needle size: the 40 mm HR is a generously long needle, indicated for wide suture planes or deep tissue; for smaller areas, shorter needles from the same family are available (HR 35, ref. AMP732HR3520; HR 30…), and for deep planes the HR 48 in single or double needle versions (AMP733HR4810-2).
- Gauge: USP 0 (metric 3.5) offers a very balanced medium tension for soft tissues and moderately demanding ligatures. For planes of lower resistance, consider gauges 2/0 or lower; for tissues requiring a larger diameter, the same HR 40 needle is available in USP 1 (AMP732HR4001) or USP 2 (AMP732HR4002).
- Presentation: if you prefer to reduce the opening of packages per procedure, consider the double-thread version P732HR4010.2 (AMP732HR4010.2), which keeps the same HR 40 needle and USP 0 gauge with 2 threads of 75 cm.
- Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish (superior penetration); useful when the protocol requires premium penetration quality in delicate tissues.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732HR4010 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews