Description
1. Commercial Introduction
The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction is required. This presentation incorporates double ½ circular needle with conical Taperpoint point of 20 mm (profile 2×HR20), USP 4/0 gauge and blue grooved strand of 90 cm: a versatile configuration, widely used in the approximation and ligation of soft tissues and in cardiovascular surgery, ophthalmology and neurosurgery procedures.
It is supplied sterile, ready for individual use, in a box of 12 units with individual sachets and batch traceability, which facilitates hospital stock management and presentation to public tenders. It is marketed under the factory reference P733HR2040-2 (SKU Cahnos AMP733HR2040-2), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament dyed blue: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with conical point Taperpoint penetrates soft and friable tissues by separating the fibres without cutting them, minimising trauma to the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The HR20 profile of 20 mm offers excellent control in superficial and medium-thickness surgical fields. The double needle format (2×) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. The Prime quality adds a premium needle finish with grooved body and improved penetration compared to standard quality. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with highly visible fluted surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.15 – 0.199 mm |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue, grooved, high visibility in the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 20 mm (2 × HR20, double needle) |
| Manufacturing quality | Prime (premium finish, improved penetration) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P733HR2040-2 |
| Reference Cahnos (SKU) | AMP733HR2040-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
3.3. Variants of the Premisut Prime 2×HR20 family (½ circle, cylindrical body, conical point, 90 cm, blue)
| Configuration | Cahnos / factory reference | Observations |
| 2×HR20 Prime – USP 4/0 (this product) | AMP733HR2040-2 (P733HR2040-2) | Double HR20 needle, 20 mm |
| 2×HR20 Prime VisiBlack – USP 4/0 | AMP733HR2040-2VB (P733HR2040-2VB) | Black needle with maximum visibility |
| 2×HR25 Prime – USP 4/0 (standard needle) | AMP733HR2540-2 (P733HR2540-2) | HR25 needle, 25 mm |
| 2×HR25 Prime VisiBlack – USP 4/0 | AMP733HR2540-2VB (P733HR2540-2VB) | Black HR25 needle, medium-depth fields |
| 2×HR20 Prime – USP 3/0 | AMP733HR2030-2 (P733HR2030-2) | Gauge 3/0 for higher mechanical demand |
| 2×HR20 Prime – USP 5/0 | AMP733HR2050-2 (P733HR2050-2) | Fine gauge for microsurgery |
| HR20 Prime – USP 4/0, single needle | AMP732HR2040 (P732HR2040) | 1 × 75 cm, single needle |
4. Equivalences and Cross-References
The reference P733HR2040-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2×HR20, double 20 mm needle, USP 4/0 gauge and blue 90 cm thread) and Cahnos markets it without altering characters. Blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (commercially type «Prolene»). There is no manufacturer-validated equivalence table that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1 without prior technical validation against each manufacturer’s technical data sheet or IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene ½ circle 2×HR20, USP 4/0, blue, 90 cm (standard needle) | P733HR2040-2 / AMP733HR2040-2 | Exact reference equivalence (current product) | Official reference of the analysed product; code verified in Cahnos internal catalogue without altering characters |
| Cahnos (Premisut Prime) | 1/2 circle conical 2×HR20, USP 4/0, blue, 90 cm (black VisiBlack needle) | P733HR2040-2VB / AMP733HR2040-2VB | Direct range equivalent | Same material, gauge, HR20 needle and length; only the VisiBlack finish of the needle varies |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 4/0, 90 cm, double needle SH half circle taper point of 26 mm | 8521H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, double needle and 90 cm match; SH needle of 26 mm versus HR20 of 20 mm; presentation in box of 36 units |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 4/0 (1.5), 90 cm, double needle 2×HR26 CV with conical point | C2090907 (G2090907) | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue and medical device registration (GUDID): same material, gauge, colour and double conical needle; HR26 needle of 26 mm versus HR20 of 20 mm |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, 4/0 (1.5), 90 cm, double needle 2×HR26 CV | C3090907 | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue: same gauge and double needle configuration; the material (polypropylene and polyethylene copolymer versus pure polypropylene) and the 26 mm needle differ |
| DemeTECH | DemeLENE™ – polypropylene, DSH half circle round body 26 mm, blue, USP 4-0, 36 in (90 cm) | PM1094026C0P | Comparable by category, not interchangeable 1:1 | SKU verified in official DemeTECH store: same material, gauge, colour and 90 cm; DSH needle of 26 mm round body versus HR20 of 20 mm |
| Serag-Wiessner | SERAPREN® – blue monofilament polypropylene, USP 4/0 (EP 1.5), 90 cm, double needle 2×HR-26 | CP15443C | Comparable by category, not interchangeable 1:1 | Reference verified in official SERAPREN catalogue: same material, gauge and length; HR26 needle of 26 mm versus HR20 of 20 mm; presentation in box of 24 units |
Mandatory technical note: there is no manufacturer-validated equivalence table cross-referencing reference P733HR2040-2 with other brands; comparisons with PROLENE®, Premilene®, Optilene®, DemeLENE™ or SERAPREN® are functional, at category level, and not interchangeable 1:1 without prior technical validation against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. Consult the technical department at Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the conical-point (Taperpoint) needle with cylindrical body is the choice for soft, friable and thin-walled vascular tissues, as it separates fibres without cutting them (optimal in cardiovascular surgery, ophthalmology and neurosurgery). If the protocol requires passing through more fibrous tissues or calcified adventitia, consider the trocar-point (Tapercut) variant from the same range.
- Needle size: the HR20 of 20 mm is ideal for superficial and medium-thickness surgical fields, very common in ophthalmology and vascular microsurgery. If you need greater reach in deeper planes, the HR25 from the same Prime family is available (ref. AMP733HR2540-2VB in VisiBlack); for reduced or paediatric fields, consider the HR16.
- Gauge: USP 4/0 (metric 1.5) offers an excellent balance between strength and manageability for fine tissues and delicate vascular structures. With the same 2×HR20 Prime needle, gauges 3/0 (AMP733HR2030-2) and 5/0 (AMP733HR2050-2) are also available depending on the tissue plane to suture.
- Double-needle format: the 2×HR20 presentation allows continuous suturing and anastomosis techniques with two armed ends without rethreading, optimising surgical time and material consumption. If you prefer a single 75 cm thread with a single needle, choose the AMP732HR2040 variant.
- Prime and VisiBlack range: the Premisut Prime line maintains the standard geometry with an improved needle finish (superior penetration); if needle visibility is critical, choose the VisiBlack variant with a black needle (ref. AMP733HR2040-2VB). As an economical alternative, the normal PREMISUT quality maintains needle, gauge, colour and length.
- Prior verification: always check the full reference (2×HR20 needle, USP 4/0 gauge and 90 cm length) on the packaging, as well as the integrity of the blister and the expiry date before each use; keep the reference P733HR2040-2 and the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use; store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.