Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the reference choice for surgical departments, procurement centres and tenders that need a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with full control. This presentation in USP 0 gauge, with a ½ circle taper point fluted needle 35 mm (HR 35 Prime profile) and double blue thread 75 cm (2×75 cm), is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Factory reference P732HR3510.2, marketed by Cahnos as SKU AMP732HR3510.2, maintaining the official manufacturer’s nomenclature without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as uncoated monofilament, dyed blue with phthalocyanine for maximum visibility in the surgical field. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not promote bacterial adhesion or sinus formation in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period according to USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The HR 35 Prime needle (½ circle, cylindrical body and taper point fluted 35 mm) separates and displaces tissue fibres without cutting them, making it ideal for soft tissues, vascular tissues and slightly distensible planes that require controlled penetration and minimal injury. The fluted finish of the needle improves grip in the needle holder and facilitates smooth and consistent delivery during knotting. The double thread presentation (2×75 cm) allows continuous suture techniques and anastomosis with two armed ends without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut – Prime quality (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin, (C3H6)n) |
| Thread structure | Monofilament with fluted surface/needle (HR 35 Prime profile) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Number of threads | 2 threads per pack |
| Thread length | 2 × 75 cm (2 threads of 75 cm) |
| Thread colour | Identification blue (phthalocyanine), high visibility |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved |
| Needle size | 35 mm (HR 35 Prime profile / RHR 35 ribbed prime) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3510.2 |
| Reference Cahnos (SKU) | AMP732HR3510.2 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
The reference P732HR3510.2 corresponds to the official nomenclature of the Premisut Prime range (fluted HR 35 Prime profile, double thread 75 cm, USP 0 gauge, blue colour) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene HR 35 Prime, USP 0, blue, 1×75 cm | P732HR3510 / AMP732HR3510 | Configuration equivalent within the same system | Same HR 35 fluted needle and USP 0 gauge; presentation changes to single thread (1×75 cm). |
| Cahnos (Premisut) | Polypropylene HR 35, USP 0, blue, 1×75 cm (standard) | 732HR3510 / AM732HR3510 | Direct equivalent within the same family | Same measurements and material; standard quality needle versus Prime. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, ½ circle needle with conical tip | NW846 (USP 0, blue, 90 cm, RB needle of 30 mm) | Comparable by category (not interchangeable 1:1) | Same material, gauge and colour; differ in thread length (90 cm) and needle (30 mm) versus HR 35 fluted 35 mm. Verified in official Ethicon catalogue. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, ½ circle conical point | CP-424 (USP 0, blue, 75 cm, GS-21 needle, 37 mm) | Comparable by category (not interchangeable 1:1) | Same gauge and taper point; copolymer material and needle 37 mm versus 35 mm; presentation of 1 thread. Verify in official Medtronic catalogue. |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical taper point needle | 37020 (C24, needle 37 mm, USP 0, 1×75 cm) | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour and length (75 cm); cylindrical taper point needle 37 mm non-fluted and single thread presentation. Verified in Laboratorio Aragó catalogue. |
| B. Braun | Premilene® / Dafilon® / Optilene® – blue polypropylene monofilament | Series C2090 (configuration HR35 USP 0 2×75 cm pending confirmation) | Pending confirmation | Sector family with same clinical indication; confirm needle geometry and length in official B. Braun catalogue before use. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Laboratorio Aragó or Premilene®/Dafilon® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR taper point fluted needle is indicated for soft tissues, vascular tissues and slightly distensible planes requiring penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point (HRT) or triangular profiles from the same Premisut Prime range.
Needle size: the 35 mm HR is ideal for medium-depth fields. If a shorter needle is required, the HR 30 (ref. AMP732HR3010) or HR 25 (ref. AMP732HR2510) are available in USP 0 and 75 cm; for wider planes, the HR 40 (ref. AMP732HR4010.2 in USP 0 and double thread).
Gauge: USP 0 offers a very balanced medium-high tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR 35 Prime family offers 3/0 (ref. AMP732HR3530.2) or 2/0 (ref. AMP732HR3520.2); for greater strength, USP 1 (ref. AMP732HR3501.2) with the same needle and double thread presentation.
Presentation: the 2×75 cm double-thread version (SKU AMP732HR3510.2) optimises use per procedure and reduces the number of packs opened. If you prefer to open one pack per use, consider the single-thread version P732HR3510 (SKU AMP732HR3510) or the standard alternative outside the Prime range AM732HR3510. For a longer thread length, the 2×90 cm version (ref. AMP733HR3510.2) is available.
Prime range: the Premisut Prime line retains the geometry of the standard version with an improved needle finish (superior penetration); useful when the protocol requires premium quality in delicate tissues.
Sterility verification: single-use product sterilised with ethylene oxide; check the integrity of the blister and the expiry date before each use and retain the reference P732HR3510.2 and the batch number for traceability in the operating theatre. Store below 30 °C, protected from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.