Description
1. Product Presentation
The polypropylene suture PREMISUT is the reference choice for surgery departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with full control. This presentation in gauge USP 0 mounts a ½-circle needle with cylindrical body and taperpoint conical tip of 25 mm (perfil HR25) and a blue fluted thread 75 cm, designed for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and the approximation and ligation of soft tissues.
Supplied sterile and ready for single use in a box of 12 units with individual pouches and batch traceability. Available at Cahnos under the factory reference 732HR2510 (SKU AM732HR2510), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as monofilamento no recubierto, dyed blue. Lacking interstices and wick effect, it offers very smooth sliding through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR25 needle (½ circle, cylindrical body) with taperpoint conical tip separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The fluted finish of the needle improves grip in the needle holder and facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin, (C3H6)n) |
| Structure | Monofilament of a single filament, without coating or braiding |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Grooved blue identifier, high visibility in the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, grooved (HR25 profile) |
| Needle size | 25 mm (HR25 profile) |
| Manufacturing quality | Standard (PREMISUT range; for premium finish see Prime variant) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | 732HR2510 |
| Reference Cahnos (SKU) | AM732HR2510 |
3.2. Gauge equivalence according to USP/EP standard (non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm |
3.3. Family PREMISUT HR25 (½ circle, cylindrical body, conical point) and range variants
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| HR25 (standard) | 0 | 1 × 75 cm | 732HR2510 / AM732HR2510 (this product) |
| HR25 (standard) | 1 | 1 × 75 cm | 732HR2501 / AM732HR2501 |
| HR25 (standard) | 2/0 | 1 × 75 cm | 732HR2520 / AM732HR2520 |
| HR25 (standard) | 3/0 | 1 × 75 cm | 732HR2530 / AM732HR2530 |
| HR25 (standard) | 4/0 | 1 × 75 cm | 732HR2540 / AM732HR2540 |
| HR25 (standard) | 5/0 | 1 × 75 cm | 732HR2550 / AM732HR2550 |
| HR35 (standard) | 0 | 1 × 75 cm | 732HR3510 / AM732HR3510 |
| 2×HR25 (standard) | 4/0 | 2 × 90 cm | 733HR2540-2 / AM733HR2540-2 |
4. Equivalences and Cross-References
Reference 732HR2510 corresponds to the official nomenclature of the PREMISUT range (fluted HR25 profile, single thread 75 cm, USP gauge 0, blue colour) and Cahnos markets it with characters unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are funcionales, a nivel de categoría, y no intercambiables 1:1, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (PREMISUT Prime) | Polypropylene HR25 Prime, USP 0, blue, 75 cm | P732HR2510 / AMP732HR2510 | Range equivalent within the same system | Same fluted HR25 needle, gauge, colour and length; needle finish changes to Prime range (improved penetration). Confirm availability in Cahnos catalogue. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 75 cm, CT needle ½ circle conical point | 8434H | Comparable by category (not interchangeable 1:1) | Verified in official Ethicon catalogue. Material, gauge, colour and thread length (75 cm) match; the CT needle is 40 mm compared to the HR25 of 25 mm. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene, blue monofilament, USP 0, GS-21 needle ½ circle conical point of 37 mm, 75 cm | CP-424 | Comparable by category (not interchangeable 1:1) | Verified in official Medtronic catalogue. Same gauge, colour, conical tip and length; copolymeric material (polypropylene/polyethylene) and needle of 37 mm compared to 25 mm. |
| DemeTECH | DemeLENE® – blue polypropylene monofilament, USP 0, DCT-1 needle ½ circle round body of 36 mm, 75 cm | PM290036B0P | Comparable by category (not interchangeable 1:1) | Verified in official DemeTECH store. Same material, gauge, colour and length; conical needle of 36 mm non-fluted compared to fluted HR25 of 25 mm. |
| B. Braun | Premilene® – blue polypropylene monofilament (Easyslide series) | Series C2090 (HR25 configuration USP 0 75 cm pending confirmation) | Pending confirmation | Sector family with same clinical indication; confirm geometry, needle size and exact code in official B. Braun catalogue before use. |
Nota técnica obligatoria: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, DemeLENE® or Premilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tejido a suturar: the fluted Taperpoint conical tip HR25 needle is indicated for soft, vascular and non-distensible flat tissues that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar tip (HRT) or triangular (DS) profiles from the same PREMISUT range.
Calibre: USP 0 offers a very balanced medium-high tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR25 needle is available in 2/0 (ref. AM732HR2520), 3/0 (ref. AM732HR2530), 4/0 (ref. AM732HR2540) or 5/0 (ref. AM732HR2550); for greater strength, in USP 1 (ref. AM732HR2501).
Medida de aguja: the HR of 25 mm is ideal for superficial and medium-thickness tissues. If you need greater reach in deep fields, the HR30 (ref. AM732HR3010 in USP 0) or HR35 (ref. AM732HR3510 in USP 0 and 75 cm) are available.
Gama Prime y presentaciones: the PREMISUT Prime line maintains the same needle geometry with premium finish for improved penetration. If you prefer to use each opening with two armed ends, consider the double-needle versions 2×90 cm from the 733 series (e.g. ref. AM733HR2540-2 in USP 4/0).
Verificación previa: always check USP gauge, colour, thread length and needle size before placing the order, as well as the integrity of the blister and the expiry date before each use. Keep the reference 732HR2510 and the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use; store below 30 °C, protected from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.