Description
1. Commercial Introduction
The PREMISUT polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation incorporates a double ½-circle needle with Taperpoint conical point, 20 mm (2×HR20 profile), USP 2/0 gauge and a 90 cm blue strand: a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability, which facilitates hospital stock management and submission to public tenders. It is marketed under the factory reference 733HR2020-2 (SKU Cahnos AM733HR2020-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with Taperpoint conical point passes through soft and friable tissues by separating the fibres without cutting them, minimising trauma to the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The 20 mm HR20 profile offers excellent control in superficial and medium-thickness surgical fields. The double-needle format (2×) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. The high-visibility grooved blue strand facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with highly visible fluted surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.30 – 0.339 mm |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue (fluted) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 20 mm (2 × HR20, double needle) |
| Configuration | Double needle (2 × HR20) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 733HR2020-2 |
| Reference Cahnos (SKU) | AM733HR2020-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
3.3. PREMISUT family 2×HR20 (½ circle, cylindrical body, taper point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2×HR 20 (standard) | 2 × 90 cm, USP 2/0 (product analysed) | 733HR2020-2 / AM733HR2020-2 |
| 2×HR 20 Prime | 90 cm, USP 2/0, premium finish | P733HR2020-2 / AMP733HR2020-2 |
| 2×HR 20 (standard) | 2 × 90 cm, USP 3/0 | 733HR2030-2 / AM733HR2030-2 |
| 2×HR 20 Prime | 90 cm, USP 3/0, 4/0 and 5/0 | P733HR2030-2, P733HR2040-2, P733HR2050-2 (AMP series) |
| 2×HR 25 (standard) | 2 × 90 cm, USP 2/0 | 733HR2520-2 / AM733HR2520-2 |
| 2×HR 30 (standard) | 2 × 90 cm, USP 2/0 | 733HR3020-2 / AM733HR3020-2 |
| 2×HRT 20/25 (Tapercut trocar point) | 2 × 90 cm, USP 2/0 | 733HRT2020-2, 733HRT2520-2 (AM series) |
| HR 25 (standard, single needle) | 1 × 75 cm, USP 2/0 | 732HR2520 / AM732HR2520 |
4. Equivalences and Cross-References
Reference 733HR2020-2 corresponds to the official nomenclature of the PREMISUT range (2×HR20 profile, double conical-point needle, USP 2/0 gauge, 90 cm blue thread). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT (Cahnos) | Polypropylene 1/2 circle 2×HR20, USP 2/0, blue, 90 cm | 733HR2020-2 / AM733HR2020-2 | Exact reference equivalence (current product) | Official reference of the analysed product |
| PREMISUT Prime (Cahnos) | Polypropylene 1/2 circle 2×HR20, USP 2/0, blue, 90 cm | P733HR2020-2 / AMP733HR2020-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime version) |
| PREMISUT (Cahnos) | Polypropylene 1/2 circle 2×HR20, USP 3/0, blue, 90 cm | 733HR2030-2 / AM733HR2030-2 | Configuration equivalent (same system) | Same 2×HR20 needle and length; gauge changes to USP 3/0 |
| PREMISUT (Cahnos) | Polypropylene 1/2 circle 2×HR25, USP 2/0, blue, 90 cm | 733HR2520-2 / AM733HR2520-2 | Configuration equivalent (same system) | Same gauge, colour and length; HR25 needle of 25 mm versus HR20 of 20 mm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 90 cm, double SH ½-circle needle with conical point, 26 mm | 8523H | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; SH needle of 26 mm versus HR20 of 20 mm; usual box of 36 units. Verified in official Ethicon catalogue and authorised distribution. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 2/0 (metric 3), 90 cm, double 2×HR26 CV needle with conical point | C2090909 | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; HR26 needle of 26 mm versus HR20 of 20 mm; RacePack packaging. Verified in B. Braun catalogue. |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, USP 2/0, 90 cm, double 2×HR26 needle with conical point | C3090909 | Comparable by category (not interchangeable 1:1) | Copolymeric composition (PP/PE) versus pure polypropylene; HR26 needle of 26 mm. Verified in official B. Braun catalogue and GUDID/FDA. |
| DemeTECH | DemeLENE™ – polypropylene, USP 2/0, blue, double DSH ½-circle needle with round body, 26 mm, 90 cm | PM1092026C0P | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; DSH needle of 26 mm round body without grooved surface. Verified in authorised distributor’s technical data sheet. |
| TAGUM | Polypropylene monofilament, USP 2/0, blue, double 1/2 circle tapered needle of 25 mm, 90 cm | TGPP1115ZL | Comparable by category (not interchangeable 1:1) | Same gauge, colour and double-needle configuration; verify needle finish and packaging in the manufacturer’s data sheet. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 2/0, conical point, ½ circle | VP945 | Comparable by category (not interchangeable 1:1) | Copolymer material (not pure polypropylene); 30″ thread (≈76 cm) versus 90 cm and V-30 needle of 30 mm; pack of 36 units. Verified in authorised distribution. |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the PREMISUT line versus other brands. Before substituting in tender documents, protocols or the operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical versus trocar), needle size, material (pure polypropylene versus copolymer) and regulatory classification (CE/MDR) of the actual product from each manufacturer. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. For tissues with some fibrosis or resistance (vascular adventitia, fascia), consider the trocar-point (Tapercut) variant of the same family (e.g. AM733HRT2020-2 or AM733HRT2520-2, USP 2/0, 90 cm).
USP gauge 2/0 (metric EP 3): offers an excellent balance between strength and handling, widely used in cardiovascular, vascular and soft tissue surgery under moderate tension. For finer tissues, the same 2×HR20 needle is available in USP 3/0 (AM733HR2030-2), 4/0 (AMP733HR2040-2) and 5/0 (AMP733HR2050-2).
Needle length: the 20 mm HR is ideal for superficial and medium-thickness surgical fields. If greater reach is needed in deeper planes, consider the 25 mm HR (AM733HR2520-2) or the 30 mm HR (AM733HR3020-2) from the same standard range, in USP gauge 2/0.
Double-needle format 2×90 cm: designed for continuous suture and anastomosis techniques with two armed ends, without rethreading, optimising surgical time. If you prefer a single 75 cm thread with a single needle, choose the AM732HR2520 variant (HR25, USP 2/0). The premium Prime range (P733HR2020-2 / AMP733HR2020-2) maintains the same needle geometry with improved penetration finish.
Verification and storage: always check the full reference (needle 2×HR20, USP gauge 2/0 and length 90 cm) on the packaging, as well as the integrity of the blister and the expiry date before each use; keep the lot number for traceability in the operating theatre. Sterile product by ethylene oxide and single-use; store below 30 °C, protected from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews