Description
1. Commercial Introduction
The polypropylene suture PREMISUT in HR 40 configuration is the usual choice in surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 1 gauge, with a ½ circle Taperpoint conical point needle of 40 mm and blue thread of 75 cm, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, which facilitates hospital stock management and presentation to public tenders. Cahnos markets the product keeping the factory reference 732HR4001 unchanged (SKU AM732HR4001).
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (molecular formula (C3H6)n) presented as an uncoated monofilament, dyed blue with phthalocyanine (composition ≥ 99.5% polypropylene, ≤ 0.5% blue colorant). Lacking interstices and wick effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion.
It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months. The HR 40 needle (½ circle, cylindrical body and 40 mm Taperpoint conical point) separates and displaces tissue fibres without cutting them, making it suitable for soft, vascular and poorly distensible planes that require controlled penetration and minimal injury. The grooved finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. Recommended storage below 30 °C, away from humidity and direct sunlight.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Line | PREMISUT – standard quality (standard manufacturing) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (phthalocyanine); ≥ 99.5 % polypropylene / ≤ 0.5 % phthalocyanine |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 1 (metric EP 4); approximate diameter 0.350 – 0.399 mm; conforming to USP and European Pharmacopoeia calibres |
| Thread length | 1 thread of 75 cm per unit |
| Thread colour | Identifying blue, high visibility |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved (HR profile) |
| Needle size | 40 mm (HR 40 profile) |
| Manufacturing quality | Standard (not Prime) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732HR4001 |
| Reference Cahnos (SKU) | AM732HR4001 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence (USP/EP standard)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 1 | 4 | 0.350 – 0.399 mm |
Variants of the HR 40 family (½ circle, Taperpoint conical point, 40 mm needle)
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| HR 40 (standard) | 0 | 1 × 75 cm | 732HR4010 / AM732HR4010 |
| HR 40 (standard) | 1 | 1 × 75 cm | 732HR4001 / AM732HR4001 (this product) |
| HR 40 (standard) | 2 | 1 × 75 cm | 732HR4002 / AM732HR4002 |
| HR 40 Prime | 0 | 1 × 75 cm | P732HR4010 / AMP732HR4010 |
| HR 40 Prime | 0 | 2 × 75 cm | P732HR4010.2 / AMP732HR4010.2 |
| HR 40 Prime | 1 | 1 × 75 cm | P732HR4001 / AMP732HR4001 |
| HR 40 Prime | 1 | 2 × 75 cm | P732HR4001.2 / AMP732HR4001.2 |
| HR 40 Prime | 2 | 1 × 75 cm | P732HR4002 / AMP732HR4002 |
| HR 40 Prime | 2 | 2 × 75 cm | P732HR4002.2 / AMP732HR4002.2 |
4. Equivalences and Cross-References
Reference 732HR4001 corresponds to the official nomenclature of the PREMISUT range (standard HR 40 profile, 1 thread of 75 cm, USP 1 gauge, blue colour), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT (Cahnos) | Polypropylene HR 40, USP 1, blue, 1 × 75 cm (standard) | 732HR4001 / AM732HR4001 | Direct product reference | Product analysed in this data sheet |
| PREMISUT Prime (Cahnos) | Polypropylene HR 40 Prime, USP 1, blue, 1 × 75 cm | P732HR4001 / AMP732HR4001 | Direct equivalent within the same family | Same measurements and material; Prime quality needle (PREMILLOY steel, improved penetration) versus standard |
| PREMISUT Prime (Cahnos) | Polypropylene HR 40 Prime, USP 1, blue, 2 × 75 cm | P732HR4001.2 / AMP732HR4001.2 | Configuration equivalent within the same system | Same HR 40 needle and USP 1 calibre; presentation changes to double thread |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 1 (EP 4), 75 cm, HR 40 needle of 40 mm, ½ circle, conical point | C2090200 (Premilene 1 HR40S BL) | Functional equivalence by specifications (no official cross-reference table) | High match: material, gauge (EP 4), length of 75 cm and HR 40 needle of 40 mm in ½ circle with conical point. Needle finish and commercial presentation differ; verify batch and IFU |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 1, 75 cm, CT-1 needle of ½ circle, conical point | 8425H | Comparable by category (not 1:1) | Material, gauge, colour and length match; the CT-1 needle is 36.4 mm versus the HR 40 of 40 mm and the presentation is 36 units. Confirm needle measurement and CE/MDR traceability against IFU |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical (conical) needle of 40 mm, USP 1 | 37096 (C30, 1 × 100 cm) | Comparable by category (not 1:1) | Material, colour, gauge and needle geometry match (40 mm, ½ circle, conical); thread length differs (100 cm versus 75 cm) |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, blue monofilament | CP-424 (verified in USP 0 calibre); pending confirmation for USP 1 | Comparable by category / pending confirmation | Same clinical indication; copolymeric material (not pure polypropylene). Confirm reference, gauge and needle geometry in the official catalogue before any substitution |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands. Comparisons with Premilene® C2090200, PROLENE® 8425H, Surgipro™ CP-424 or Laboratorio Aragó 37096 are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR needle with Taperpoint conical point is suitable for soft, vascular and poorly distensible planes requiring non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider triangular point profiles (reverse cutting) from the same PREMISUT range.
Needle measurement: the 40 mm HR is a generously long needle, indicated for wide suture planes or deep tissue; for smaller areas, shorter needles from the same family are available (HR 35, HR 30…) and for deep planes the HR 48.
Gauge: USP 1 (metric 4) provides medium-high tension for soft tissues and moderately demanding ligatures. For less demanding planes, USP 0 (AM732HR4010) is available, and for tissues requiring a larger diameter, USP 2 (AM732HR4002) with the same HR 40 needle.
Presentation and Prime range: if you prefer a needle with improved penetration, consider the Prime version P732HR4001 (AMP732HR4001); if you seek to optimise packaging opening, the double-thread version P732HR4001.2 (AMP732HR4001.2).
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732HR4001 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews