Description
1. Product Presentation
The polypropylene suture PREMISUT that Cahnos makes available to surgical services, purchasing centres and tenders is a reliable solution with predictable behaviour for the approximation and ligation of soft tissues. This presentation incorporates a half-circle needle with a cylindrical body and taper-point conical tip of 25 mm (HR 25 profile), gauge USP 4/0 and a 75 cm blue fluted thread: a classic configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of delicate soft tissues.
Supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability. Available from Cahnos under the factory reference 732HR2540 (SKU Cahnos AM732HR2540), kept with characters unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: as it has no interstices or wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (half-circle, cylindrical body) with a Taperpoint conical tip separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The blue fluted thread ensures optimal visibility and better knot grip on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5; diameter 0.15 – 0.199 mm); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (fluted, high visibility) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 25 mm (HR 25) |
| Configuration | Single needle (1 × HR 25) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732HR2540 |
| Reference Cahnos (SKU) | AM732HR2540 |
Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
PREMISUT HR 25 family (½ circle, cylindrical body, conical tip) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| HR 25 (standard, single needle) | 1 × 75 cm, USP 4/0 (product analysed) | 732HR2540 / AM732HR2540 |
| HR 25 (Prime, single needle) | 1 × 75 cm, USP 4/0 | P732HR2540 / AMP732HR2540 |
| HR 25 (standard, single needle) | 1 × 75 cm, USP 3/0 | 732HR2530 / AM732HR2530 |
| 2×HR 25 (standard, double needle) | 2 × 90 cm, USP 4/0 | 733HR2540-2 / AM733HR2540-2 |
| 2×HR 25 (Prime, double needle) | 2 × 90 cm, USP 4/0 | P733HR2540-2 / AMP733HR2540-2 |
4. Equivalences and Cross-References
Reference 732HR2540 corresponds to the official nomenclature of the PREMISUT range (HR 25 profile, single taper-point needle, USP 4/0 gauge, 75 cm blue thread). Blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (Prolene type). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene ½ circle HR 25, USP 4/0, blue, 75 cm | P732HR2540 / AMP732HR2540 | Direct equivalent (same system) | Same HR 25 needle, gauge, colour and length; only the premium finish of the needle varies (Prime version versus standard). |
| Cahnos (Premisut) | Polypropylene ½ circle HR 17, USP 4/0, blue, 75 cm | 732HR1740 / AM732HR1740 | Configuration equivalent (same system) | Same material, gauge, colour and length; HR 17 needle of 17 mm versus the HR 25 of 25 mm (shorter reach in deep fields). |
| Ethicon (J&J MedTech) PROLENE® | Blue polypropylene monofilament, USP 4/0, 75 cm, RB-1 ½ circle conical tip needle of 17 mm | 8871H | Comparable by category (not interchangeable 1:1) | Material, gauge, colour, length and conical tip match; the RB-1 needle of 17 mm is shorter than the HR 25 of 25 mm; presentation in a box of 36 units. Verified in authorised Ethicon distribution. |
| Ethicon (J&J MedTech) PROLENE® | Blue polypropylene monofilament, USP 4/0, 90 cm, double needle SH ½ circle conical tip of 26 mm | 8521H / 8521T | Comparable by category (not interchangeable 1:1) | Material, gauge and conical tip match; SH needle of 26 mm and double-needle configuration with 90 cm thread versus the single HR 25 of 75 cm. Verified in authorised Ethicon distribution. |
| B. Braun (Aesculap) Premilene® | Blue polypropylene, USP 4/0 (1.5), 75 cm, HRT 17 ½ circle trocar point needle | C2090315 (GUDID GTIN 04046963632243; confirmed in GUDID database: PREMILENE 4/0 (1.5) 75CM HRT17 (M)) | Comparable by category (not interchangeable 1:1) | Material, gauge (EP 1.5) and 75 cm length match; the needle profile differs: HRT 17 with trocar point versus the HR 25 with conical point, and commercial presentation. Verify IFU. |
| B. Braun Optilene® | Polypropylene-polyethylene copolymer, blue, USP 4/0 (1.5), 75 cm, HR17 conical tip needle | C3090013 | Comparable by category (not interchangeable 1:1) | Gauge, colour and length match; but the material is a copolymer (not pure polypropylene) and the needle is HR17 of 17 mm, so it is not interchangeable 1:1. Confirm IFU. |
| Medtronic (Covidien) Surgipro™ II | Polypropylene with polyethylene copolymer, blue, 4-0, 75 cm, CV-23 ½ circle conical tip needle | VP-871-X | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle with conical tip. Copolymer material (polypropylene with polyethylene), composition different from the PREMISUT thread. Verified in authorised distributors. |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; before substituting in a specification, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical vs. trocar), needle size, material (pure polypropylene vs. copolymer) and the regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult the technical department of Cahnos before using this information in tenders or direct substitution.
5. Selection tips and variants of interest
Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. For tissues with some fibrosis or resistance, consider the trocar-point (Tapercut) variant of the same family (e.g. AM732HRT1740 in 4/0).
USP 4/0 gauge: fine thread with high manageability, widely used in cardiovascular surgery, ophthalmology and delicate soft tissue. If greater strength is required, the same HR 25 needle is available in 3/0 gauge (AM732HR2530) and the double-needle version in 2/0 (AM733HR2520-2).
Needle size: the 25 mm HR is ideal for superficial and medium-thickness planes; for smaller fields, the HR 15 (AM732HR1540) and HR 17 (AM732HR1740) are available in the same gauge, and if greater reach is needed in deep fields, consider 35 mm or 48 mm needles from the same range. A double-needle version 2xHR25 with 90 cm thread (AM733HR2540-2) is also available for continuous suturing and anastomosis, as well as the premium Prime range (AMP732HR2540) with superior needle finish.
Prior verification: always confirm the full reference (HR 25 needle, USP 4/0 gauge and 75 cm length) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.