We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-absorbable polyester suture Premisut Prime USP 3/0, double ⅜ circle trocar point needle (2×DRT) of 17 mm, white multifilament thread coated with silicone, 75 cm | Box of 12 units (Ref. AMP872DRT1730-2)

Original price was: 96,83 €.Current price is: 60,90 €.

Non-absorbable multifilament polyester suture Premisut Prime, USP 3/0 gauge, with double ⅜ circle needle, cylindrical body and trocar point (tapercut) of 17 mm (2×DRT). White 75 cm thread braided from polyethylene terephthalate and coated with silicone, which facilitates tissue sliding, knot advancement and reduces tissue trauma. Non-absorbable: gradual encapsulation with wound support exceeding three months. Indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Sterilised by ethylene oxide, in a box of 12 units; minimum order of 10 boxes. Reference Cahnos AMP872DRT1730-2.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP872DRT1730-2

Description

1. Commercial Introduction

The polyester suture Premisut Prime in a double-needle ⅜ circle configuration, cylindrical body and 17 mm trocar (tapercut) point is the reference choice for surgical services seeking a high-performance non-absorbable suture with uniform handling and predictable tissue behaviour. Supplied in USP 3/0 gauge, white and 75 cm length, it allows professionals to standardise criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology, neurosurgery and cardiovascular surgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure and designed for centralised purchasing by the surgical block.

2. Technical explanation

The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone. This coating improves passage through tissue, facilitates knot seating and reduces tissue trauma and sawing effect, without compromising tensile strength. Being non-absorbable, it does not degrade or lose strength through the body’s enzymatic action: it permanently maintains its tensile strength, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place.

The ⅜ circle needle allows suturing over wide surfaces with controlled rotational movements, while the trocar (tapercut) point combines the penetration of a cutting needle with the minimal aggression of a round needle: the cutting edge opens the way and the cylindrical body dilates the tissue without cutting it, which is especially useful in dense or fibrous planes such as fascia, dura mater or ocular and vascular structures. The double-needle configuration (2×DRT) incorporates a needle at each end of the thread, allowing continuous sutures with two half-arcs without repositioning the needle in the needle holder, optimising surgical time in reduced fields.

3. Technical Specifications

Characteristic Specification
Thread material Braided multifilament polyester (polyethylene terephthalate) coated with silicone
Suture type Non-absorbable, synthetic multifilament, coated, non-channelling
Gauge USP 3/0 (EP metric 2; approximate diameter 0.20–0.249 mm)
Thread length 75 cm
Needle shape ⅜ circle (3/8)
Tip type Cylindrical body with trocar point (tapercut)
Needle configuration and size Double needle 2×DRT, 17 mm (stainless steel)
Thread colour White (undyed); also available in green
Behaviour No absorption; gradual encapsulation; tissue support exceeding 3 months
Tensile strength Permanent; exceeds USP and EP requirements
Sterilisation Ethylene oxide (EO)
Presentation Box of 12 units (individual sterile sachets)
Minimum order 10 boxes
Shelf life 5 years
Regulatory standard Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements
Indications Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and cardiovascular surgery
Factory reference P872DRT1730-2
SKU Cahnos AMP872DRT1730-2

Gauge equivalence (USP / EP)

USP size Metric measurement (EP) Approximate diameter
3/0 2 0.20 – 0.249 mm

4. Equivalences and Cross-References

Non-absorbable braided polyester suture is a well-established market category, present in most major manufacturers. The located reference is indicated below with its equivalence level; remember that only a code change of the same product retains the condition of direct equivalent and that exact reference equivalence can only be declared within the same manufacturer.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) ETHIBOND EXCEL, coated braided polyester W6923 Comparable by category (not interchangeable 1:1) Same objective configuration: USP 3/0, white thread 75 cm, double 17 mm needle with trocar (tapercut) point and ⅜ circle curvature. The coating differs: Ethicon’s own polybutylate lubricant versus silicone; verify regulatory classification and batch registration before substituting. Code verified in an authorised distributor catalogue (Aston Pharma).

There is no manufacturer-validated equivalence table cross-referencing the Premisut reference with other brands; the cross-reference with Ethicon is a functional category comparison pending official confirmation. There is no manufacturer-validated equivalence table; consult the technical department at Cahnos before use in tenders or reference substitution.

5. Selection tips and variants of interest

Dense or fibrous tissues: the 17 mm trocar (tapercut) point offers controlled penetration with minimal aggression; if the procedure requires greater travel or deeper tissue, consider the variant with a 25 mm needle (AMP871DRT2540-2 in USP 4/0 white, 45 cm). Single-colour protocols: if your centre standardises green suture, reference AMP852DRT1730-2 maintains the same 2×DRT 17 mm needle and the same USP 3/0 gauge with green thread, 75 cm. Mixed multipack: to combine green and white in gauge 2/0, reference AMP883DRT1720.10-2 offers 10 × 90 cm in a 5 + 5 presentation. Before switching brand: always check needle angle (3/8), size (17 mm), point type (trocar/tapercut), double-needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet. Storage: sterile product by ethylene oxide, single-use and not re-sterilisable, with a 5-year shelf life; respect storage conditions and the expiry date on the packaging. Request a personalised quotation from our technical-commercial department for hospital volumes.

Additional information

Material

Braided multifilament polyester (polyethylene terephthalate, PET) coated with silicone

Structure

Braided multifilament, non-grooved

Coating

Silicone

Absorbability

Non-absorbable

USP size

USP 3/0 (metric EP 2)

Metric gauge (EP)

2 (approximate diameter 0.20–0.249 mm)

Tip type

Cylindrical body with trocar point (tapercut)

Needle size

17 mm

Needle configuration

Double needle (2xDRT)

Needle material

Stainless steel

Suture colour

White (undyed); also available in green

Absorption

Non-absorbable; gradual encapsulation, tissue support exceeding 3 months

Tensile strength

Permanent; exceeds USP and EP requirements

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

10 boxes

Shelf life

5 years

Regulatory standard

Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements

Indications

Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and cardiovascular surgery

Manufacturer reference

P872DRT1730-2

Medida de aguja

2xDRT 17 prime

Usp

3/0

Color

White

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polyester suture Premisut Prime USP 3/0, double ⅜ circle trocar point needle (2×DRT) of 17 mm, white multifilament thread coated with silicone, 75 cm | Box of 12 units (Ref. AMP872DRT1730-2)”

Your email address will not be published. Required fields are marked *