Description
1. Commercial Introduction
The polyester suture Premisut Prime in a double-needle ⅜ circle configuration, cylindrical body and 17 mm trocar (tapercut) point is the reference choice for surgical services seeking a high-performance non-absorbable suture with uniform handling and predictable tissue behaviour. Supplied in USP 3/0 gauge, white and 75 cm length, it allows professionals to standardise criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology, neurosurgery and cardiovascular surgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone. This coating improves passage through tissue, facilitates knot seating and reduces tissue trauma and sawing effect, without compromising tensile strength. Being non-absorbable, it does not degrade or lose strength through the body’s enzymatic action: it permanently maintains its tensile strength, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place.
The ⅜ circle needle allows suturing over wide surfaces with controlled rotational movements, while the trocar (tapercut) point combines the penetration of a cutting needle with the minimal aggression of a round needle: the cutting edge opens the way and the cylindrical body dilates the tissue without cutting it, which is especially useful in dense or fibrous planes such as fascia, dura mater or ocular and vascular structures. The double-needle configuration (2×DRT) incorporates a needle at each end of the thread, allowing continuous sutures with two half-arcs without repositioning the needle in the needle holder, optimising surgical time in reduced fields.
3. Technical Specifications
| Characteristic | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone |
| Suture type | Non-absorbable, synthetic multifilament, coated, non-channelling |
| Gauge | USP 3/0 (EP metric 2; approximate diameter 0.20–0.249 mm) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8) |
| Tip type | Cylindrical body with trocar point (tapercut) |
| Needle configuration and size | Double needle 2×DRT, 17 mm (stainless steel) |
| Thread colour | White (undyed); also available in green |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and cardiovascular surgery |
| Factory reference | P872DRT1730-2 |
| SKU Cahnos | AMP872DRT1730-2 |
Gauge equivalence (USP / EP)
| USP size | Metric measurement (EP) | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
4. Equivalences and Cross-References
Non-absorbable braided polyester suture is a well-established market category, present in most major manufacturers. The located reference is indicated below with its equivalence level; remember that only a code change of the same product retains the condition of direct equivalent and that exact reference equivalence can only be declared within the same manufacturer.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL, coated braided polyester | W6923 | Comparable by category (not interchangeable 1:1) | Same objective configuration: USP 3/0, white thread 75 cm, double 17 mm needle with trocar (tapercut) point and ⅜ circle curvature. The coating differs: Ethicon’s own polybutylate lubricant versus silicone; verify regulatory classification and batch registration before substituting. Code verified in an authorised distributor catalogue (Aston Pharma). |
There is no manufacturer-validated equivalence table cross-referencing the Premisut reference with other brands; the cross-reference with Ethicon is a functional category comparison pending official confirmation. There is no manufacturer-validated equivalence table; consult the technical department at Cahnos before use in tenders or reference substitution.
5. Selection tips and variants of interest
Dense or fibrous tissues: the 17 mm trocar (tapercut) point offers controlled penetration with minimal aggression; if the procedure requires greater travel or deeper tissue, consider the variant with a 25 mm needle (AMP871DRT2540-2 in USP 4/0 white, 45 cm). Single-colour protocols: if your centre standardises green suture, reference AMP852DRT1730-2 maintains the same 2×DRT 17 mm needle and the same USP 3/0 gauge with green thread, 75 cm. Mixed multipack: to combine green and white in gauge 2/0, reference AMP883DRT1720.10-2 offers 10 × 90 cm in a 5 + 5 presentation. Before switching brand: always check needle angle (3/8), size (17 mm), point type (trocar/tapercut), double-needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet. Storage: sterile product by ethylene oxide, single-use and not re-sterilisable, with a 5-year shelf life; respect storage conditions and the expiry date on the packaging. Request a personalised quotation from our technical-commercial department for hospital volumes.





Reviews
There are no reviews yet.