Description
1. Product Presentation
The polyester suture Premisut Prime with a ⅜ circle needle and 19 mm reverse cutting triangular point (DS 19) is the go-to reference for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength permanent suture with predictable clinical performance. This unit combines a silicone-coated braided multifilament, USP gauge 4/0, green thread of 75 cm and a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Prime quality guarantees a smooth surface, smooth passage through tissue and excellent knot retention. Sterile product, ready to use, presented in a box of 12 units.
2. Technical explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer that is presented in a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the sliding of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention.
As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The ⅜ circular needle with a 19 mm reverse cutting triangular point cuts the tissue plane without tearing it, making it especially useful in ophthalmic surgery, microsurgery and approximation of tissue planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field.
3. Technical Specifications
| Material | Silicone-coated braided multifilament polyester (polyester – polyethylene) |
| Thread structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable – gradual encapsulation, support for more than 3 months |
| Thread gauge | USP 4/0 (metric 1.5) |
| Thread length | 75 cm |
| Colour | Green (also available in white depending on variant) |
| Needle type | Reverse cutting triangular point (inverted triangular) |
| Needle shape | ⅜ circle |
| Needle size | DS 19 (19 mm) |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Prime (Premisut) |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery |
| Presentation | Box of 12 units – minimum order 30 boxes |
| References | SKU Cahnos AMP852DS1940 / Manufacturer ref. P852DS1940 (P852DS series) |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widespread permanent suture family on the market for approximation of soft tissues and ligatures. In terms of material and clinical performance, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester. There is no manufacturer-validated equivalence table that cross-references these brands with the DS 19 ⅜ circular reverse cutting needle configuration; the DS 19 needle is only interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | PremiCron (braided and silicone-coated) | C002 series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Matches in material, silicone coating and gauge; verify needle geometry and size against the IFU |
| Medtronic (Covidien) | Ti-Cron (silicone-coated braided polyester) | Code series D / CD / ED (consult official catalogue) | Comparable by category, not interchangeable 1:1 | Same base material and coating; needle geometries different from the DS 19 |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (coated braided polyester) | EH series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); verify needle size and shape |
| Teleflex (Deknatel) | Tevdek II (PTFE-coated braided polyester) | 7-xxx series (consult official catalogue) | Comparable by category, not interchangeable 1:1 | PTFE coating (not silicone); different presentation and needle geometry |
Traceability note: before substituting in a tender or surgical protocol, each item must be verified one by one against the technical data sheet and IFU of each manufacturer: exact needle shape and size, USP gauge, thread length, colour, coating, regulatory classification (MDR) and sterility conditions. Consult the technical department of Cahnos to validate the exact equivalence before use.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 4/0 is ideal for delicate approximation planes, ophthalmic surgery and neurosurgery; consider USP 3/0 (AMP852DS1930) for tissues with greater mechanical demands and larger gauges (USP 0, DS 36) for ligatures subjected to higher tension.
Within the Cahnos catalogue you will find variants of the same Prime family with reverse cutting needle: AMP852DS1640 (DS 16 mm, USP 4/0, green), AMP852DS1930 (DS 19 mm, USP 3/0, green) and AMP852DS3610 (DS 36 mm, USP 0, green). If your purchasing centre requires a standard profile, the reference AM852DS1940 maintains the same needle and gauge configuration with conventional quality control. For other thread structures with the same needle, you have the monofilament polypropylene version and the absorbable PGA (AMP112DS1940). The standard presentation is the box of 12 units with a minimum order of 30 boxes; for larger volumes or supply agreements, contact the commercial department of Cahnos.





Reviews
There are no reviews yet.