Description
1. Product Presentation
The polyester suture Premisut Prime with a ⅜ circular needle and reverse cutting triangular point of 16 mm (DS 16) is the reference solution for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a permanent, high-strength thread with predictable clinical performance. This reference combines a braided multifilament coated with silicone, USP 5/0 gauge, green thread of 75 cm and a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Its Prime quality guarantees a regular surface, smooth passage through tissue and excellent knot retention. Sterile product, ready to use, presented in a box of 12 units.
2. Technical Explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, which provides flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the sliding of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention, although this suture has a grooved surface.
As it is not absorbed, the suture undergoes gradual encapsulation by connective tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The ⅜ circle needle with triangular body and reverse cutting point (inverted triangular) of 16 mm cuts the tissue plane without tearing it, making it especially useful in ophthalmic surgery, microsurgery and approximation of planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field. Sterilised by ethylene oxide, it is single-use and must not be re-sterilised.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the distributor (Cahnos S.L.).
| Parameter | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone (polyester – polyethylene) |
| Structure | Braided multifilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, support for more than 3 months |
| USP gauge / size | USP 5/0 (metric 1). Conforms to USP and European Pharmacopoeia gauges. |
| Thread colour | Green (also available in white depending on variant) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8) |
| Needle type | Reverse cutting triangular point (triangular body and point; inverted triangular) |
| Needle size | DS 16 (16 mm) |
| Sterilisation | Ethylene oxide (EO) — sterile |
| Use | Single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Quality | Prime (Premisut Prime) |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
| Factory reference | P852DS1650 |
| SKU Cahnos | AMP852DS1650 |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical performance, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester. There is no manufacturer-validated equivalence table that cross-references these brands with the DS 16 ⅜ circle reverse cutting needle configuration; the DS 16 needle is only interchangeable within the Premisut system itself. Before substituting in a tender or surgical protocol, each must be verified one by one against the technical data sheet and instructions for use of each manufacturer: exact shape and size of the needle, USP gauge, thread length, colour, coating and regulatory classification. Consult the technical department of Cahnos to validate the exact equivalence before use.
| Manufacturer / Brand | Family / Model | Equivalence level | Technical differences / Remarks |
| Cahnos (same Premisut system) | Premisut Normal quality, DS 16, USP 5/0, green, 75 cm — AM852DS1650 | Configuration equivalence within the same system (identical needle, gauge, colour and length) | They differ in Prime quality control and surface finish |
| Cahnos (same Premisut system) | Premisut Prime, DS 16, USP 4/0, green, 75 cm — AMP852DS1640 | Comparable within the same system (same needle and length) | Changes the USP gauge (4/0 instead of 5/0) |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (coated braided polyester) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); verify needle size and shape against the IFU |
| B. Braun | PremiCron (braided and silicone-coated) | Comparable by category, not interchangeable 1:1 | Matches in material and silicone coating; verify needle geometry and size |
| Medtronic (Covidien) | Surgidac / Ti-Cron (braided polyester) | Comparable by category, not interchangeable 1:1 | Same base material; Surgidac uncoated and Ti-Cron with silicone; needle geometries different from DS 16 |
| Teleflex (Deknatel) | Tevdek II (PTFE-coated braided polyester) | Comparable by category, not interchangeable 1:1 | PTFE coating (not silicone); different presentation and needle geometry |
Traceability note: comparisons between brands are functional equivalents by category, not interchangeable 1:1; the DS 16 reverse cutting needle is only interchangeable within the Premisut system itself. For substitutions in tenders, contact the technical department of Cahnos.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 5/0 is ideal for very delicate approximation planes, ophthalmic surgery and neurosurgery; consider USP 4/0 (AMP852DS1640) or 3/0 (AMP852DS1630) for tissues with greater mechanical demands, and larger gauges (USP 0, DS 36) for ligatures under higher tension. The DS 16 reverse cutting needle is especially suitable for reduced working fields.
Prime variants of the same family with reverse cutting needle: AMP852DS1630 (DS 16, USP 3/0), AMP852DS1640 (DS 16, USP 4/0), AMP852DS1930 (DS 19, USP 3/0), AMP852DS1940 (DS 19, USP 4/0), AMP852DS3010 (DS 30, USP 0) and AMP852DS3610 (DS 36, USP 0). Same configuration in Normal quality: AM852DS1650, identical needle, gauge, colour and length with conventional quality control. For atraumatic conical point in the same 5/0 gauge, the double needle 2xDR of 13 mm (AMP852DR1350-2) is available. Other materials with similar configurations: nylon, polypropylene monofilament, silk (non-absorbable) and PGA, PGCL and PDO (absorbable).
The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes, white colour, special gauges or supply agreements, contact the commercial department of Cahnos.





Reviews