We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Polyester suture Premisut Prime 3/0 green 75 cm – ⅜ circle needle DS 19 mm reverse cutting triangular point (Ref. P852DS1930)

Original price was: 38,56 €.Current price is: 28,30 €.

Non-absorbable polyester suture Premisut Prime, silicone-coated braided multifilament, USP 3/0 gauge, 75 cm green thread and ⅜ circle needle with 19 mm reverse cutting triangular point (DS 19). Non-absorbable, with gradual encapsulation and high tensile strength that maintains wound support for more than three months. Sterilised by ethylene oxide and indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Presentation in a box of 12 units, minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP852DS1930

Description

1. Product Presentation

The Premisut Prime polyester suture with a ⅜ circle needle and 19 mm reverse cutting triangular point (DS 19) is the reference solution for general surgery, ophthalmology, neurosurgery departments and purchasing centres seeking a high-strength permanent suture with predictable clinical performance. This reference combines a silicone-coated braided multifilament, USP 3/0 gauge, 75 cm green thread and a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Its Prime quality ensures a regular surface, smooth passage through tissue and excellent knot retention. Sterile, ready-to-use product, supplied in a box of 12 units.

2. Technical explanation

Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates thread passage through tissues and minimises the sawing effect, improving handling without compromising knot retention.

As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, during which the wound completes its critical healing phase. The ⅜ circle needle with a 19 mm reverse cutting triangular point (reverse cutting) cuts through the tissue plane without tearing it, making it particularly useful in ophthalmic surgery, microsurgery and approximation of planes with restricted working fields. The green colour ensures optimal thread visibility on the surgical field.

3. Technical Specifications

Material Silicone-coated braided multifilament polyester (polyester – polyethylene)
Thread structure Braided multifilament, non-grooved surface
Absorption Non-absorbable, gradual encapsulation
Thread gauge USP 3/0
Thread length 75 cm
Colour Green (also available in white)
Needle type Triangular reverse cutting point (reverse cutting)
Needle shape ⅜ circle
Needle size DS 19 (19 mm)
Tensile strength Maintained for more than 3 months
Sterilisation Ethylene oxide
Quality Prime (Premisut)
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units
Minimum order 30 boxes
References SKU Cahnos AMP852DS1930 / Manufacturer ref. P852DS1930

4. Equivalences and Cross-References

Non-absorbable braided polyester is the most widely used permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical performance, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:

Manufacturer / Brand Family / Model Reference code Equivalence level Technical differences / Remarks
B. Braun PremiCron (braided and silicone-coated) C002 series (consult official catalogue for gauge and needle) Comparable by category, not interchangeable 1:1 Matches in material, silicone coating and gauge; verify needle geometry and size (DS 19 reverse cutting) against the IFU
Medtronic (Covidien) Ti-Cron (silicone-coated braided polyester) Code series D / CD / ED (consult official catalogue) Comparable by category, not interchangeable 1:1 Same base material and coating; needle geometries different from the DS 19
Ethicon (Johnson & Johnson MedTech) ETHIBOND EXCEL (coated braided polyester) EH series (consult official catalogue for gauge and needle) Comparable by category, not interchangeable 1:1 Polybutylate coating (not silicone); verify needle size and shape
Teleflex (Deknatel) Tevdek II (PTFE-coated braided polyester) 7-xxx series (consult official catalogue) Comparable by category, not interchangeable 1:1 PTFE coating (not silicone); different presentation and needle geometry

Traceability note: there is no manufacturer-validated equivalence table cross-referencing these brands with the DS 19 ⅜ circle reverse cutting needle configuration; the above comparisons are functional category equivalents, not interchangeable 1:1. The DS 19 needle is only interchangeable within the Premisut system itself. Before substituting in a tender or surgical protocol, each must be verified one by one against each manufacturer’s technical data sheet and IFU: exact needle shape and size, USP gauge, thread length, colour, coating, regulatory classification (MDR) and sterility conditions. Consult the Cahnos technical department to validate the exact equivalence before use.

5. Selection tips and variants of interest

Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 is suitable for soft tissue approximation, ophthalmic surgery and neurosurgery; consider USP 4/0 for more delicate planes and larger gauges (USP 0, 1) for tissues under greater tension.

Within the Cahnos catalogue you will find variants of the same Prime family with reverse cutting needle: AMP852DS1630 (DS 16 mm needle, USP 3/0), AMP852DS1640 (DS 16 mm, USP 4/0), AMP852DS1940 (DS 19 mm, USP 4/0) and AMP852DS3610 (DS 36 mm, USP 0). If your purchasing centre requires a standard profile, the reference AM852DS1930 maintains the same configuration with conventional quality control. For other thread structures with the same needle, a monofilament polypropylene version and an absorbable PGA version are available. The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes or supply agreements, contact the Cahnos commercial department.

Additional information

Material

Silicone-coated braided multifilament polyester (polyester – polyethylene)

Structure

Braided multifilament, non-grooved surface

Absorption

Non-absorbable, gradual encapsulation

Gauge

USP 3/0

Needle type

Triangular reverse cutting point (reverse cutting)

Needle size

DS 19 (19 mm)

Tensile strength

Maintained for more than 3 months

Sterilisation

Ethylene oxide

Presentation

Box of 12 units

Minimum order

30 boxes

Quality

Prime (Premisut)

Manufacturer reference

P852DS1930

Medida de aguja

DS 19

Usp

3/0

Color

Green

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polyester suture Premisut Prime 3/0 green 75 cm – ⅜ circle needle DS 19 mm reverse cutting triangular point (Ref. P852DS1930)”

Your email address will not be published. Required fields are marked *