Description
1. High-performance permanent suture for demanding surgery
The Premisut Prime polyester suture with a ⅜ circular reverse cutting triangular-point needle of 30 mm (DS 30) is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength non-absorbable thread with predictable clinical performance. This reference combines a braided multifilament coated with silicone, USP 0 gauge and a green 75 cm thread, mounted on a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Its Prime quality guarantees a regular surface, smooth passage through tissue and excellent knot retention, providing prolonged mechanical support during healing. Sterile product, ready to use and presented in a box of 12 units for professional supply.
2. Technical Explanation
Polyester (polyethylene terephthalate, PET) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the thread’s passage through tissues and minimises the sawing effect, improving handling without compromising knot retention.
As it is not absorbed, the suture undergoes gradual encapsulation by connective tissue and maintains its structural integrity for more than three months, during which the wound completes its critical healing phase. The ⅜ circle needle with triangular body and reverse cutting point (reverse cutting) of 30 mm is designed to precisely traverse firm, inelastic tissues, cutting the tissue plane without tearing it, making it especially useful in ophthalmology, microsurgery and approximation of planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone |
| Structure | Braided multifilament, silicone coating |
| Absorption type | Non-absorbable; without absorption, gradual encapsulation |
| USP gauge / size | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Colour | Green (also available in white depending on reference) |
| Needle shape | ⅜ circle (3/8) |
| Needle point type | Reverse cutting triangular (body and point; reverse cutting) |
| Needle size | DS 30 (30 mm) |
| Sterilisation | Ethylene oxide (EO) |
| Wound support | More than three months |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Quality | Prime (line Premisut) |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Factory reference | P852DS3010 |
| SKU Cahnos | AMP852DS3010 |
4. Equivalences and Cross-References
Non-absorbable braided polyester is one of the most widespread permanent suture families on the market for soft tissue approximation and ligatures. There is no official equivalence table validated by the manufacturer cross-referencing this specific configuration (DS 30 ⅜ circle reverse cutting needle) with other brands; therefore, the references cited below are declared as functional category comparisons, not interchangeable 1:1 without prior verification against each manufacturer’s technical data sheet and IFU. The DS 30 needle is only interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
| Cahnos (same Premisut system) | Premisut, DS 30, USP 0, green, 75 cm | AM852DS3010 | Configuration equivalence within the same system | Same needle, calibre, colour and length with standard quality control; this reference is the Prime version |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL | EH7688H (USP 0, green, 75 cm, FSL cutting needle) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); FSL cutting needle; verify exact point geometry and presentation against the IFU |
| B. Braun | PremiCron | C0026017 / C0026067 (USP 0, green, 75 cm) | Comparable by category, not interchangeable 1:1 | Same braided polyester with silicone and same gauge; confirm needle size and geometry before any substitution |
| Medtronic (Covidien) | Ti-Cron / Surgidac | 8886309061 (USP 0, green, 75 cm, GS-21 needle) | Comparable by category, not interchangeable 1:1 | Same gauge and length, but GS-21 ½ circle trocar point needle; needle geometry different from the DS 30 reverse cutting; Surgidac uncoated and Ti-Cron with silicone |
| Teleflex (Deknatel) | Tevdek / Tevdek II | 7-555 (USP 0, reverse cutting) | Pending confirmation with manufacturer | PTFE coating (not silicone); verify technical data sheet and needle geometry before any substitution |
Important note: there is no equivalence table validated by the manufacturer cross-referencing these brands with the DS 30 ⅜ circular reverse cutting needle configuration; the DS 30 needle is only interchangeable within the Premisut system itself. Consult the Cahnos technical department before using this information in tenders or direct substitution.
5. Selection tips and variants of interest
Before placing the order, verify three parameters: USP gauge (this reference is 0, suitable for planes with medium-high mechanical demand and ligatures), needle size (DS 30 = 30 mm) and thread length/colour (75 cm green). If your protocol requires another gauge with the same needle, the DS 30 Prime family is available in USP 2/0 (ref. AMP852DS3020) and USP 1 (ref. AMP852DS3001), as well as the standard version AM852DS3010 with conventional quality control and identical configuration. For tissues requiring a longer needle, see the DS 36 variant (ref. AMP852DS3610); for fine gauges, the DS 16 range (ref. AMP852DS1630, AMP852DS1640, AMP852DS1650) and DS 19 (ref. AMP852DS1930, AMP852DS1940). If you prioritise monofilament with the same needle geometry, consider Premisut DS 30 polypropylene (ref. 732DS3001/732DS3020). For larger volumes, white colour, special gauges or supply agreements, contact the Cahnos commercial department.





Reviews