Description
1. Product Presentation
The Premisut Prime polyester suture with a ⅜ circular needle and a 16 mm reverse cutting triangular point (DS 16) is the reference solution for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength permanent thread with predictable clinical behaviour. This reference combines a silicone-coated braided multifilament, USP 3/0 gauge, green 75 cm thread and a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Its Prime quality guarantees a regular surface, smooth passage through tissue and excellent knot retention. Sterile, ready-to-use product, supplied in a box of 12 units.
2. Technical explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the passage of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention.
As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The ⅜ circular needle with a 16 mm reverse cutting triangular point (triangular body and point) cuts the tissue plane without tearing it, making it especially useful in ophthalmic surgery, microsurgery and approximation of planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field.
3. Technical Specifications
| Parameter | Specification |
| Material | Silicone-coated braided multifilament polyester (polyester – polyethylene) |
| Thread structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable, gradual encapsulation |
| Thread gauge | USP 3/0 (metric 2) |
| Thread length | 75 cm |
| Colour | Green (also available in white depending on variant) |
| Needle type | Triangular reverse cutting point (reverse cutting) |
| Needle shape | ⅜ circle |
| Needle size | DS 16 (16 mm) |
| Tensile strength | Maintained for more than 3 months |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Prime (Premisut) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| References | SKU Cahnos AMP852DS1630 / Manufacturer ref. P852DS1630 |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widely used permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
| B. Braun | PremiCron (braided and silicone-coated) | C002 series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Matches in material and silicone coating; verify needle geometry and size (DS 16 reverse cutting) against the IFU |
| Medtronic (Covidien) | Ti-Cron / Surgidac (silicone-coated braided polyester) | Code series D / CD / ED (consult official catalogue) | Comparable by category, not interchangeable 1:1 | Same base material and coating; needle geometries different from DS 16 |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (coated braided polyester) | EH series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); verify needle size and shape |
| Teleflex (Deknatel) | Tevdek II (PTFE-coated braided polyester) | 7-xxx series (consult official catalogue) | Comparable by category, not interchangeable 1:1 | PTFE coating (not silicone); different presentation and needle geometry |
Traceability note: there is no manufacturer-validated equivalence table cross-referencing these brands with the DS 16 ⅜ circular reverse cutting needle configuration; the above comparisons are functional equivalents by category, not interchangeable 1:1. The DS 16 needle is only interchangeable within the Premisut system itself. Before substituting in a tender or surgical protocol, each must be verified one by one against the technical data sheet and IFU of each manufacturer: exact needle shape and size, USP gauge, thread length, colour, coating, regulatory classification (MDR) and sterility conditions. Consult the Cahnos technical department to validate the exact equivalence before use.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 is ideal for soft approximation tissues, ophthalmic surgery and neurosurgery; consider USP 4/0 for more delicate planes and larger gauges (USP 0) for tissues under greater tension.
Within the Cahnos catalogue you will find variants of the same Prime family with reverse cutting needle: AMP852DS1930 (DS 19 mm, USP 3/0), AMP852DS1640 (DS 16 mm, USP 4/0), AMP852DS1650 (DS 16 mm, USP 5/0), AMP852DS1940 (DS 19 mm, USP 4/0) and AMP852DS3610 (DS 36 mm, USP 0). If your purchasing centre requires a standard profile, the AM852DS1630 reference maintains the same needle and gauge configuration with conventional quality control. For other thread structures, a monofilament polypropylene version and an absorbable PGA version with the same needle are available. The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes, white colour, special gauges or supply agreements, contact the Cahnos commercial department.





Reviews