We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-absorbable polyester suture Premisut Prime 3/0 green 75 cm with ⅜ circle needle, triangular point, reverse cutting, DS 16 mm (Ref. P852DS1630)

Original price was: 38,56 €.Current price is: 28,30 €.

Non-absorbable surgical suture of multifilament braided polyester coated with silicone, line Premisut Prime, with a ⅜ circle reverse cutting needle with triangular point, 16 mm (DS 16), USP 3/0 gauge, 75 cm green thread with high visibility on the surgical field. Non-absorbable: gradual encapsulation that maintains wound support for more than three months, with high tensile strength and secure knots. Sterilised by ethylene oxide and indicated for approximation of soft tissues, ligatures, ophthalmology and neurosurgery. Presentation in a box of 12 units with a minimum order of 30 boxes; professional B2B supply. Reference AMP852DS1630 (factory equivalent P852DS1630).

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP852DS1630

Description

1. Product Presentation

The Premisut Prime polyester suture with a ⅜ circular needle and a 16 mm reverse cutting triangular point (DS 16) is the reference solution for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength permanent thread with predictable clinical behaviour. This reference combines a silicone-coated braided multifilament, USP 3/0 gauge, green 75 cm thread and a reverse cutting needle designed to penetrate firm tissues while minimising trauma. Its Prime quality guarantees a regular surface, smooth passage through tissue and excellent knot retention. Sterile, ready-to-use product, supplied in a box of 12 units.

2. Technical explanation

Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the passage of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention.

As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The ⅜ circular needle with a 16 mm reverse cutting triangular point (triangular body and point) cuts the tissue plane without tearing it, making it especially useful in ophthalmic surgery, microsurgery and approximation of planes with reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field.

3. Technical Specifications

Parameter Specification
Material Silicone-coated braided multifilament polyester (polyester – polyethylene)
Thread structure Braided multifilament, non-grooved surface
Absorption Non-absorbable, gradual encapsulation
Thread gauge USP 3/0 (metric 2)
Thread length 75 cm
Colour Green (also available in white depending on variant)
Needle type Triangular reverse cutting point (reverse cutting)
Needle shape ⅜ circle
Needle size DS 16 (16 mm)
Tensile strength Maintained for more than 3 months
Sterilisation Ethylene oxide (EO)
Quality Prime (Premisut)
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units
Minimum order 30 boxes
References SKU Cahnos AMP852DS1630 / Manufacturer ref. P852DS1630

4. Equivalences and Cross-References

Non-absorbable braided polyester is the most widely used permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:

Manufacturer / Brand Family / Model Reference code Equivalence level Technical differences / Remarks
B. Braun PremiCron (braided and silicone-coated) C002 series (consult official catalogue for gauge and needle) Comparable by category, not interchangeable 1:1 Matches in material and silicone coating; verify needle geometry and size (DS 16 reverse cutting) against the IFU
Medtronic (Covidien) Ti-Cron / Surgidac (silicone-coated braided polyester) Code series D / CD / ED (consult official catalogue) Comparable by category, not interchangeable 1:1 Same base material and coating; needle geometries different from DS 16
Ethicon (Johnson & Johnson MedTech) ETHIBOND EXCEL (coated braided polyester) EH series (consult official catalogue for gauge and needle) Comparable by category, not interchangeable 1:1 Polybutylate coating (not silicone); verify needle size and shape
Teleflex (Deknatel) Tevdek II (PTFE-coated braided polyester) 7-xxx series (consult official catalogue) Comparable by category, not interchangeable 1:1 PTFE coating (not silicone); different presentation and needle geometry

Traceability note: there is no manufacturer-validated equivalence table cross-referencing these brands with the DS 16 ⅜ circular reverse cutting needle configuration; the above comparisons are functional equivalents by category, not interchangeable 1:1. The DS 16 needle is only interchangeable within the Premisut system itself. Before substituting in a tender or surgical protocol, each must be verified one by one against the technical data sheet and IFU of each manufacturer: exact needle shape and size, USP gauge, thread length, colour, coating, regulatory classification (MDR) and sterility conditions. Consult the Cahnos technical department to validate the exact equivalence before use.

5. Selection tips and variants of interest

Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 is ideal for soft approximation tissues, ophthalmic surgery and neurosurgery; consider USP 4/0 for more delicate planes and larger gauges (USP 0) for tissues under greater tension.

Within the Cahnos catalogue you will find variants of the same Prime family with reverse cutting needle: AMP852DS1930 (DS 19 mm, USP 3/0), AMP852DS1640 (DS 16 mm, USP 4/0), AMP852DS1650 (DS 16 mm, USP 5/0), AMP852DS1940 (DS 19 mm, USP 4/0) and AMP852DS3610 (DS 36 mm, USP 0). If your purchasing centre requires a standard profile, the AM852DS1630 reference maintains the same needle and gauge configuration with conventional quality control. For other thread structures, a monofilament polypropylene version and an absorbable PGA version with the same needle are available. The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes, white colour, special gauges or supply agreements, contact the Cahnos commercial department.

Additional information

Material

Silicone-coated braided multifilament polyester (polyester – polyethylene)

Structure

Braided multifilament, non-grooved surface

Absorption

Non-absorbable, gradual encapsulation (support for more than 3 months)

Gauge

USP 3/0 (metric 2)

Needle type

Triangular reverse cutting point (reverse cutting)

Needle size

DS 16 (16 mm)

Sterilisation

Ethylene oxide (EO)

Quality

Prime (Premisut)

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P852DS1630

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Medida de aguja

DS 16

Usp

3/0

Color

Green

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polyester suture Premisut Prime 3/0 green 75 cm with ⅜ circle needle, triangular point, reverse cutting, DS 16 mm (Ref. P852DS1630)”

Your email address will not be published. Required fields are marked *