We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-absorbable polyester suture Premisut 3/8 triangular DS 19 mm, USP 4/0 white, 45 cm thread (Ref. 871DS1940) – Box of 12 units

Original price was: 35,00 €.Current price is: 25,00 €.

Non-absorbable multifilament polyester suture Premisut with ⅜ circular needle with reverse cutting triangular point (body and point) of 19 mm (DS 19), USP 4/0 gauge, white 45 cm thread and silicone coating for smooth passage and minimal tissue reactivity. No absorption: gradual encapsulation that maintains wound support for more than three months. Sterilised by ethylene oxide, indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Supplied in a box of 12 units with a minimum order of 30 boxes. Factory reference 871DS1940 (SKU AM871DS1940).

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM871DS1940

Description

1. Commercial Introduction

The polyester suture Premisut 3/8 triangular DS 19 mm, USP 4/0 white and 45 cm (Ref. 871DS1940) is the choice of the professional who needs a reliable non-absorbable suture, with excellent handling and a very competitive quality-price ratio for hospital procurement and purchasing centres. Its ⅜ circular needle configuration with a 19 mm reverse cutting triangular point offers firm and controlled penetration in compact tissues, making it especially valuable in ophthalmology, neurosurgery and soft tissue approximation. It is presented in a box of 12 sterile units, ready for immediate use in the operating theatre.

2. Technical Explanation

This suture consists of a core of braided multifilament polyester (polyethylene terephthalate) coated with silicone, which ensures smooth passage through tissue, excellent knotting handling and a reduction of the sawing effect characteristic of multifilaments. Being non-absorbable, it does not degrade by enzymatic action: it offers sustained tensile strength and gradual encapsulation by fibrous connective tissue that maintains wound support for more than three months, a critical period in tissues with slow healing.

The needle with body and reverse cutting triangular point (reverse cutting) of 19 mm presents the cutting edge outward at the moment of passage, allowing it to traverse firm and poorly distensible tissues —such as skin, muscle and scar tissue— with a clean cut without tearing. The ⅜ circle radius offers an intermediate arc, very balanced for surgical fields of medium access. The product is delivered sterile and single-use, sterilised by ethylene oxide (EO); it must not be re-sterilised.

3. Technical Specifications

Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).

Property Specification
Material Silicone-coated braided multifilament polyester (polyester – polyethylene)
Structure Braided multifilament
Absorption Non-absorbable; gradual encapsulation without absorption (support exceeding 3 months)
Thread colour White (the family also offers a green version)
USP size 4/0 (metric EP 1.5). Conforms to USP and European Pharmacopoeia gauges
Needle shape ⅜ circle
Needle type Triangular reverse cutting, body and point
Needle size DS 19 mm
Thread length 45 cm
Tensile strength High tensile strength; maintains integrity for more than three months
Sterilisation Ethylene oxide (EO) — sterile
Use Single-use; do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units (individual sterile sachets)
Minimum order 30 boxes
Factory reference 871DS1940 (SKU Cahnos: AM871DS1940)

4. Equivalences and Cross-References

Braided non-absorbable polyester suture is a consolidated category in the market, present in most major manufacturers. The references indicated below are comparable at category level (same product type, same general clinical indication and same USP 4/0 gauge), but they should not be considered interchangeable 1:1: they differ in the type of coating, needle geometry (radius and point), exact diameter and presentation. Always check the manufacturer’s official technical data sheet before substituting.

Manufacturer / Brand Family / Model Equivalence level Technical differences / Remarks
Cahnos (Premisut) Polyester Premisut Prime DS 19 mm 4/0 white 45 cm (AMP871DS1940) Exact reference equivalence within catalogue Same material, needle, gauge and length; Prime finish from the same family
Ethicon (Johnson & Johnson MedTech) ETHIBOND EXCEL (braided polyester) Comparable by category — not interchangeable 1:1 Polybutylate coating versus silicone; confirm needle radius, point and presentation in the official data sheet
Ethicon (Johnson & Johnson MedTech) MERSILENE (braided polyester) Comparable by category — not interchangeable 1:1 Uncoated; more resistant tissue passage; needle and presentation to be verified
Medtronic (Covidien) SURGIDAC / TI-CRON Comparable by category — not interchangeable 1:1 Ti-Cron coated with silicone, similar to Premisut; confirm triangular point and 3/8 radius
B. Braun PREMICRON / DAGROFIL Comparable by category — not interchangeable 1:1 Coating and needle geometry to be confirmed in official data sheet

Note: there is no equivalence table validated by the manufacturer for 1:1 cross-references with other brands; consult the technical department of Cahnos before using this information in tenders or stock substitutions.

5. Selection tips and variants of interest

Needle geometry is the decisive criterion in microsurgery: the 3/8 reverse cutting triangular needle DS 19 mm is ideal for firm tissues of medium access (skin, muscle, scar tissue). This USP 4/0 configuration offers an excellent balance between fineness and strength; if the protocol requires more length, the family offers the 75 cm version in green thread (Ref. 852DS1940), and if greater fineness is needed, the 5/0 green 45 cm version (Ref. 851DS1950).

The same DS 19 / USP 4/0 configuration in other materials of the Cahnos range includes: non-absorbable such as nylon (AM641DS1940), polypropylene (AM731DS1940) and silk (AM541DS1940), and absorbable such as PGA (AM111DS1940) or PGCL (AM321DS1940), allowing supplier consolidation according to the required healing kinetics. Before ordering, confirm the specialty, needle radius, size (DS) and USP gauge required in your surgical protocol, as well as the current minimum order.

Additional information

Material

Silicone-coated braided multifilament polyester (polyester – polyethylene)

Absorption

Non-absorbable; gradual encapsulation (support for more than 3 months)

USP size

4/0 (metric EP 1.5)

Thread colour

White (also available in green)

Needle type

Triangular reverse cutting (reverse cutting), body and point

Sterilisation

Ethylene oxide (EO)

Use

Single-use; do not re-sterilise

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Manufacturer reference

871DS1940

Medida de aguja

DS 19

Usp

4/0

Color

Green, White

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Estructura hilo

Braided multifilament

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polyester suture Premisut 3/8 triangular DS 19 mm, USP 4/0 white, 45 cm thread (Ref. 871DS1940) – Box of 12 units”

Your email address will not be published. Required fields are marked *