Description
1. High-performance non-absorbable polyester suture
The PREMISUT polyester suture in Normal quality, factory reference 851DS1950 (SKU AM851DS1950), is the choice of the professional seeking a reliable non-absorbable suture with excellent handling in precision surgery. Its ⅜ circular needle configuration with a 19 mm reverse cutting triangular point, USP 5/0 gauge, 45 cm green thread and silicone coating makes it especially valuable in ophthalmology, neurosurgery and soft tissue approximation, where every needle pass must be firm, controlled and with minimal tissue damage. It is supplied in a box of 12 sterile units, ready for immediate use.
2. Technical Explanation
This suture consists of a braided multifilament polyester core (high molecular weight polyethylene terephthalate) coated with silicone, which ensures smooth passage through tissue, excellent knot handling and a reduction of the sawing effect typical of multifilaments. Being non-absorbable, it does not degrade by enzymatic action: it offers sustained tensile strength and gradual encapsulation by fibrous connective tissue that maintains wound support for more than three months, a critical period of healing in slow-healing tissues.
The 19 mm needle with a triangular body and reverse cutting point presents its cutting edge outward at the moment of passage, allowing it to penetrate firm, non-distensible tissues —such as skin, muscle and scar tissue— with a clean cut and without tearing. The ⅜ circle radius offers an intermediate arc, very well balanced for surgical fields with medium access such as those in ophthalmology and neurosurgery. The product is supplied sterile, single-use, sterilised by ethylene oxide.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the distributor (Cahnos S.L.).
| Property | Specification |
|---|---|
| Material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone |
| Structure | Braided multifilament |
| Absorption | Non-absorbable; gradual encapsulation (support for more than 3 months) |
| Thread colour | Green (the family also offers a white version) |
| USP size | 5/0 (metric EP 1; approximate diameter 0.1 mm). Conforms to USP and European Pharmacopoeia gauges |
| Needle shape | ⅜ circle |
| Needle type | Triangular reverse cutting, body and point |
| Needle size | DS 19 mm |
| Thread length | 45 cm |
| Sterilisation | Ethylene oxide (EO) — sterile |
| Use | Single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
| Factory reference | 851DS1950 (SKU Cahnos: AM851DS1950) |
4. Equivalences and Cross-References
Braided non-absorbable polyester suture is a well-established category in the market, present in most major manufacturers. The references listed below are comparable at category level (same product type, same general clinical indication and same USP 5/0 gauge), but should not be considered 1:1 interchangeable: they differ in coating type, needle geometry (radius and point), exact diameter and presentation. Always verify the manufacturer’s official technical data sheet before substituting.
| Manufacturer / Brand | Family / Model | Equivalence level | Technical differences / Remarks |
|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (braided polyester) | Comparable by category — not interchangeable 1:1 | Polybutylate coating versus silicone; confirm needle radius, point and presentation in the official data sheet |
| Ethicon (Johnson & Johnson MedTech) | MERSILENE (braided polyester) | Comparable by category — not interchangeable 1:1 | Uncoated; more resistant tissue passage; needle and presentation to be verified |
| Medtronic (Covidien) | SURGIDAC / TI-CRON | Comparable by category — not interchangeable 1:1 | Ti-Cron silicone-coated, similar to PREMISUT; confirm triangular point and 3/8 radius |
| B. Braun | PREMICRON / DAGROFIL | Comparable by category — not interchangeable 1:1 | Coating and needle geometry to be confirmed in official data sheet |
| Atramat / SMI (ophthalmic sutures) | POLISIL (ophthalmic braided polyester) | Functional comparison | Ophthalmic range with shorter needles; gauge and needle to be verified |
| SMI | SURGICRYL POLYESTER | Pending confirmation | No technical cross-reference validated with an official source |
Note: there is no equivalence table validated by the manufacturer for 1:1 cross-references with other brands; consult the technical department of Cahnos before using this information in tenders or stock substitutions. Within the Cahnos catalogue itself, the closest configuration is the Prime version of the same family, reference P851DS1950 (SKU AMP851DS1950), identical in material, needle, gauge and length, with Prime finish.
5. Selection tips and variants of interest
Needle geometry is the decisive criterion in microsurgery: the 3/8 reverse cutting triangular DS 19 mm needle is ideal for firm tissues with medium access (skin, muscle, scar tissue). If the protocol requires atraumatic separation of fibres in delicate planes, the same family offers a spatula needle (e.g. 3/8 double spatula 2xDSP of 8 mm, SKU AMP851DSP850-2).
Variants of the polyester family: other gauges (6/0, 4/0 and 3/0), lengths of 45 and 75 cm, green and white colours and DS 16 needle sizes within the same polyester price list. Check availability with the commercial department.
Same DS 19 / USP 5/0 configuration in other materials in the Cahnos range:
- Non-absorbable: nylon (AM641DS1950), polypropylene (AMP731DS1950) and silk (AM541DS1950).
- Absorbable: PGA (AM121DS1950 colourless and AM111DS1950 violet), PGCL (AM321DS1950) and PDO (AM411DS1950).
Before ordering, confirm the specialty, needle radius, size (DS) and USP gauge required in your surgical protocol, as well as the current minimum order.





Reviews
There are no reviews yet.