Description
1. Introduction
The non-absorbable polyester suture Premisut Prime is the choice of professionals seeking a high-performance material with exceptional handling and predictable tissue behaviour. This multipack presentation with double ½ circle needle, cylindrical body and 26 mm trocar point (2xHRT26) incorporates 4 threads of 90 cm in green, designed for operating theatre services with high consumption in ophthalmology, neurosurgery and soft tissue approximation. Each box contains 12 units sterilised by ethylene oxide and its purchase requires a minimum order of 10 boxes, ideal conditions for centralised purchasing and stock management.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves sliding through tissue, facilitates knot descent and reduces tissue trauma. Being non-absorbable, it does not degrade or lose strength due to the enzymatic action of the body: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The ½ circle needle allows suturing in wide spaces with controlled rotational movements, while the trocar point (tapercut) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT26) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time.
3. Technical Specifications
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 4 x 90 cm (multipack of 4 sutures) |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (tapercut) |
| Needle size | 2xHRT26 mm (double needle) |
| Colour | Green (D&C Green No. 6), non-grooved |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Reference | AMP853HRT2620.4-2 (Atlas Medical – Premisut) |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
Coding note: the official manufacturer reference from Atlas Medical is AMP853HRT2620.4-2, confirmed in the official Premisut POLYESTER catalogue (1/2 circle, cylindrical body TAPERCUT, double needle 2 x HRT 26, USP 2/0, green, 4 x 90 cm). The commercial designation «P853HRT2620.4-2» is the documentary simplification used by the distributor; the Cahnos SKU literally matches the official reference.
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm | P853HRT2620.4-2 / AMP853HRT2620.4-2 | Reference analysed / direct equivalent | Same family, same measurements and material; the official factory code is AMP853HRT2620.4-2 and the commercial variant P853HRT2620.4-2. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm | AMP853HRT2620-2 | Family equivalence | Same needle 2xHRT26, same gauge and material; individual thread of 90 cm instead of multipack 4×90. Not interchangeable 1:1 in presentation. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm with PTFE pledget 6x3x1.5 mm | AMP853HRT2620.4PL6-2 | Family equivalence | Same configuration and multipack presentation; incorporates PTFE pledget to increase the support surface. Not interchangeable 1:1. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 3/0 green, 90 cm | AMP853HRT2630-2 | Family equivalence | Same needle and geometry; finer gauge 3/0. Not interchangeable 1:1. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, USP 0 green, 90 cm | AMP853HRT2610-2 | Family equivalence | Same needle and geometry; larger gauge USP 0. Not interchangeable 1:1. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT36, 2/0 green, 90 cm | AMP853HRT3620-2 | Family equivalence | Same configuration, gauge and length; 36 mm needle instead of 26 mm. Not interchangeable 1:1. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; verify needle geometry (1/2 tapercut 26 mm), double needle configuration and USP/EP gauge. |
| B. Braun | Premicron (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Braided coated polyester; verify 1/2 angle, needle length of 26 mm and USP gauge. |
There is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or reference substitution.
5. Selection tips and variants of interest
- High consumption and centralised purchasing: the 4 x 90 cm multipack reduces the management of loose units and better amortises the minimum order of 10 boxes in ophthalmology and neurosurgery services.
- Dense or fibrous tissues: the 26 mm trocar point (tapercut) offers controlled penetration with minimal aggression; if the surgical field is very limited, consider the 17 mm needle variant (AMP853HRT1720-2).
- Protocols with stitch reinforcement: if the procedure requires increasing the support surface of the thread, the variant with PTFE pledget 6x3x1.5 mm (AMP853HRT2620.4PL6-2) is the natural alternative.
- Alternative gauges: for finer tissues, gauge 3/0 (AMP853HRT2630-2) is available and for greater mechanical strength, USP 0 (AMP853HRT2610-2), both with the same 2xHRT26 needle.
- Before changing brand: always check needle angle (1/2), size (26 mm), point type (trocar/tapercut), double needle configuration, USP/EP gauge, exact thread material and coating in the technical data sheet of the alternative manufacturer.
- Storage: sterile product by ethylene oxide with a shelf life of 5 years; respect storage conditions and the expiry date of the packaging.





Reviews