Description
1. Introduction
The polyester suture Premisut Prime with double ½ circle needle, cylindrical body and 17 mm trocar point (TAPERCUT) is the reference solution for surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Presented in USP 2/0 (EP 3) gauge, it incorporates a reinforcement pledget of 3 x 3 x 1.5 mm that increases the bearing surface of the stitch, particularly useful in soft tissues under tension or prone to tearing.
The 10 x 75 cm multipack with 5 green and 5 white threads allows operating theatres to standardise criteria in approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot seating and reduces tissue trauma. Being non-absorbable, it does not degrade by the body’s enzymatic action: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The ½ circle needle allows suturing in wide or reduced surgical fields with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT17) allows continuous sutures with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time. The 3 x 3 x 1.5 mm pledget acts as a reinforcement pad that distributes traction forces and prevents the thread from cutting through tissue at tension points.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Thread material | Polyester (polyethylene terephthalate) multifilament braided coated with silicone (polyester-polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 75 cm per thread; multipack 10 x 75 cm (5 green threads + 5 white threads) |
| Reinforcement pledget | 3 x 3 x 1.5 mm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration | Double needle 2xHRT17, stainless steel |
| Needle size | 17 mm |
| Thread colour | Green (D&C Green No. 6) and white (undyed), non-grooved |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Commercial presentation | Box of 12 units |
| Shelf life | 5 years |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos | AMP882HRT1720.10PL3-2 |
| Factory reference | P882HRT1720.10PL3-2 (Premisut Prime line) |
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 3x3x1.5 mm | AMP882HRT1720.10PL3-2 (factory ref. P882HRT1720.10PL3-2) | Reference analysed | Configuration covered by this data sheet; double needle 17 mm, gauge 2/0 and pledget 3x3x1.5 mm. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 6x3x1.5 mm | AMP882HRT1720.10PL6-2 | Family equivalence | Same needle, gauge, length and multipack; pledget with larger surface area (6x3x1.5 mm). Not interchangeable 1:1 if the protocol requires 3×3. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), without pledget | AMP882HRT1720.10-2 | Family equivalence | Same needle, gauge and multipack; without reinforcement pledget. Not interchangeable 1:1 if stitch reinforcement is required. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0, 10×75 (5+5), with pledget 6x3x1.5 mm | AMP882HRT2620.10PL6-2 | Family equivalence | Same configuration and gauge; 26 mm needle instead of 17 mm. Not interchangeable 1:1. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0, 10×75 (5+5), without pledget | AMP882HRT2620.10-2 | Family equivalence | Same configuration and multipack; 26 mm needle and without pledget. Not interchangeable 1:1. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; verify 1/2 tapercut geometry of 17 mm, double needle, pledget and USP/EP gauge. |
| B. Braun | Premicron (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Coated braided polyester; verify 1/2 angle, 17 mm trocar point, presence of pledget and USP gauge before substituting. Pending official confirmation. |
Note: there is no equivalence table validated by the manufacturer that cross-references the Premisut Prime AMP882HRT1720.10PL3-2 with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or substitution of references.
5. Selection tips and variants of interest
- Tissues under tension or friable: the 3 x 3 x 1.5 mm pledget distributes the stitch load and prevents tissue cutting; if a larger bearing surface is needed, consider the variant with 6 x 3 x 1.5 mm pledget (AMP882HRT1720.10PL6-2).
- Reduced surgical fields: the 17 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression; if a longer needle path is required, consider the 26 mm variants of this same family.
- Single-colour protocols: if your centre standardises green or white thread, references AMP853HRT1720-2 (green, 90 cm) and AMP873HRT1720-2 (white, 90 cm) maintain the same 2xHRT17 needle and 2/0 gauge.
- Alternative gauges: for finer tissue planes, reference AMP882HR1730.10-2 offers USP 3/0 with double 17 mm needle in the same polyester family.
- Centralised purchasing: for high consumption, consider the 4 x 90 cm multipack with pledget (AMP853HRT1720.4PL6-2) and the minimum order conditions for hospital volumes.
- Before switching brands: always check needle angle (1/2), size (17 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material, coating and presence of pledget in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide with a shelf life of 5 years; respect storage conditions and the expiry date of the packaging.