Description
1. Commercial Introduction
The polyester suture Premisut Prime in a ½ circle configuration, cylindrical body and 17 mm trocar point is the precision reference for surgical departments seeking a high-performance non-absorbable thread with exceptional handling and predictable tissue behaviour. Presented in USP 2/0 gauge, green colour and 90 cm length, it allows standardisation in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery.
The Prime finish (Premilloy needle) guarantees superior needle control, a regular thread surface and consistent knot run-down, making it the natural choice for centralised purchasing by the surgical block. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone. This coating improves passage through tissue, facilitates knot run-down, prevents the sawing or grooving effect and reduces tissue trauma.
Being non-absorbable, it does not degrade or lose strength through the body’s enzymatic action: it maintains its tensile strength for a prolonged period, supporting the wound for more than three months while gradual encapsulation by fibrous connective tissue occurs. The ½ circle needle allows suturing with controlled rotational movements, while the trocar point combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding. The double needle configuration (2xHRT17) allows continuous sutures and ligatures with two half-arcs without repositioning the needle in the needle holder, optimising surgical time. The green colour improves thread visibility over the surgical field.
3. Technical Specifications
3.1. General characteristics
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET) coated with silicone |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (metric size EP 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (tapercut), non-grooved |
| Needle configuration and size | Double needle 2xHRT17, 17 mm (Premilloy stainless steel) |
| Thread colour | Green (D&C Green No. 6) |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) — sterile, single-use |
| Presentation | Box of 12 units |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Factory reference | AMP853HRT1720-2 (official Atlas Medical catalogue Premisut POLYESTER, 2xHRT17 Premilloy) |
| Reference Cahnos (SKU) | AMP853HRT1720-2 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.35 – 0.399 mm (USP/EP standard) |
4. Equivalences and Cross-References
Non-absorbable braided polyester suture is a well-established category in the market. The located references are indicated below with their level of equivalence; remember that only a change in thread colour, while keeping needle, gauge and length, maintains the condition of direct equivalent within the same family.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0 green, 90 cm | AMP853HRT1720-2 | Analysed reference (direct equivalent, same product) | Official reference of the product itself according to Atlás Medical catalogue Premisut POLYESTER; same configuration, measurements and material. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0 white, 90 cm | AMP873HRT1720-2 | Family equivalence, not interchangeable 1:1 | Same needle 2xHRT17, same gauge and length; only the thread colour changes (white). Validate protocol preference. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 4/0 green, 90 cm | AMP853HRT1740-2 | Family equivalence, not interchangeable 1:1 | Same needle and length; finer USP 4/0 gauge, indicated for very delicate tissues. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 5/0 green, 90 cm | AMP853HRT1750-2 | Family equivalence, not interchangeable 1:1 | Same needle and length; USP 5/0 gauge of maximum fineness for microsurgery. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0 green, multipack 4×90 cm | AMP853HRT1720.4-2 | Family equivalence, not interchangeable 1:1 | Same needle and gauge; multipack presentation of 4 threads for high consumption. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm | AMP853HRT2620-2 | Family equivalence, not interchangeable 1:1 | Same gauge and configuration; 26 mm needle for wider surgical fields. |
| Atlas Medical (Premisut) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm (standard range) | AM853HRT2620-2 | Family equivalence, not interchangeable 1:1 | Same geometry and gauge; standard range without Prime finish or Premilloy needle. |
| B. Braun | Dagrofil / PremiCron (braided polyester) | C0849383 (verified for 2/0 EP 3, 90 cm, double needle HRT26) | Comparable by category, not interchangeable 1:1 | Same EP 3 gauge and green 90 cm thread with double needle; Dagrofil is supplied without coating compared to the silicone of Premisut and with a 26 mm needle. Verify geometry against the official data sheet. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel / Mersilene (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; verify coating, needle geometry, size and gauge in the official technical data sheet before substituting. |
| Medtronic (Covidien) | Surgidac / Ti-Cron (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Ti-Cron coated with silicone, similar to Premisut; confirm 2xHRT17 needle and presentation in the manufacturer’s official catalogue. |
Important note: there is no equivalence table validated by the manufacturer that cross-references the Premisut Prime reference with other brands; the cross-references with B. Braun, Ethicon and Medtronic are functional category comparisons pending official confirmation. Consult the technical department of Cahnos before use in tendering or reference substitution.
5. Selection tips and variants of interest
Reduced surgical fields: the 17 mm trocar needle is the shortest in the trocar point family and is ideal for microsurgery, ophthalmology and neurosurgery; for wider fields consider the 26 mm variant (AMP853HRT2620-2) or the 36 mm variant (AMP853HRT3620-2).
Delicate tissues: with the same 2xHRT17 needle, gauges 4/0 (AMP853HRT1740-2) and 5/0 (AMP853HRT1750-2) are available for maximum fineness in microsurgery.
Single-colour protocols: if your centre standardises white thread, reference AMP873HRT1720-2 keeps needle, gauge and length, changing only the thread colour.
Centralised purchasing: for high consumption, consider the multipack presentation 4×90 cm (AMP853HRT1720.4-2) and the minimum order conditions of 10 boxes with your Cahnos advisor.
Before substituting brand: always check needle angle (1/2), size (17 mm), point type (trocar), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
Storage: sterile product by ethylene oxide with a shelf life of 5 years, single-use and non-reesterilizable; observe the storage conditions and the expiry date of the packaging.





Reviews