Description
1. Introduction
The polyester suture Premisut Prime in a 1/2 circle configuration with double needle and trocar point (TAPERCUT) of 17 mm is the choice of professionals seeking a non-absorbable thread with high performance, smooth handling and predictable tissue behaviour. Presented in USP gauge 4/0, white colour and 90 cm of thread, it allows surgical services to unify criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone, which improves sliding through tissue, facilitates knot descent and reduces tissue trauma. Being non-absorbable, it does not degrade by the enzymatic action of the body: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The 1/2 circle needle allows suturing in wide or reduced surgical fields with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT17) allows continuous sutures to be performed with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time.
3. Technical Specifications
| Characteristic | Specification |
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 4/0 |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration and size | Double needle 2xHRT17 (stainless steel), 17 mm |
| Colour | White |
| Absorption | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and general surgery |
| Reference Cahnos | AMP873HRT1740-2 |
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 4/0 white, 90 cm | AMP873HRT1740-2 | Reference analysed | Same family, measurements and material; the Cahnos SKU follows the official family coding (the direct equivalent in 2/0 white is L873HRT1720-2, pattern L873… for white thread). Factory code for this reference pending official confirmation with Atlas Medical. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 2/0 white, 90 cm | AMP873HRT1720-2 | Family equivalence | Same needle, same colour and length; only the gauge differs (2/0 versus 4/0). Not interchangeable 1:1 if the gauge is a protocol requirement. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 4/0 green, 90 cm | AMP853HRT1740-2 | Family equivalence | Same needle, gauge and geometry; only the thread colour differs. Not interchangeable 1:1 if the colour is a protocol requirement. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 5/0 green, 90 cm | AMP853HRT1750-2 | Family equivalence | Same needle and geometry; finer gauge 5/0. Not interchangeable 1:1. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; verify 1/2 TAPERCUT geometry of 17 mm, double needle configuration and USP/EP gauge. |
| B. Braun | Premicron / Dagrofil (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Braided polyester (Dagrofil uncoated versus the silicone coating of Premisut); verify 1/2 angle, 17 mm trocar point and USP gauge before substituting. |
There is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or substitution of references.
5. Selection tips and variants of interest
Reduced surgical fields and dense tissues: the 17 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression; if greater needle travel is required, consider the 26 mm (AMP853HRT2620-2) or 36 mm (AMP853HRT3620) variants, both in gauge 2/0.
Ophthalmology, neurosurgery and fine surgery: USP gauge 4/0 with double needle is ideal for continuous sutures in delicate tissues; the white colour facilitates its use in fields where minimal visual interference with the tissue is desired.
Colour preference: if the protocol prefers high-visibility green thread, reference AMP853HRT1740-2 is the natural variant of this same configuration in 4/0.
High consumption: for centralised purchasing, consider the multipack presentations available in the family and take into account the minimum order of 10 boxes of this reference.
Before substituting brand: always check needle angle (1/2), size (17 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
Storage: sterile product by ethylene oxide with a shelf life of 5 years; respect the storage conditions and the expiry date of the packaging.





Reviews
There are no reviews yet.