Description
The polyester suture Premisut Prime with double ½ circle 26 mm needle and conical point is the reference solution for surgical departments seeking a high-performance non-absorbable suture with smooth handling and predictable tissue behaviour. Supplied in USP 2/0 gauge, green, with 90 cm of suture, it provides a single standard in demanding specialties such as ophthalmology and neurosurgery, as well as in the approximation and ligation of soft tissues. It is supplied sterile, ready to use, in a box of 12 units and designed for centralised purchasing by the surgical block.
Technical explanation
The suture is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves glide through tissue, facilitates knot seating and reduces tissue trauma. As it is non-absorbable, it is not degraded by the body’s enzymatic action: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place.
The ½ circle needle allows suturing in wide spaces with controlled rotational movements, and its conical point (taperpoint) passes through tissue by separating the fibres without cutting them, causing minimal tissue trauma. The double needle (2xHR26) configuration allows continuous sutures to be placed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time. The green colour ensures optimal visibility of the suture on the surgical field. Ethylene oxide sterilisation ensures a product ready for immediate use in critical procedures.
Technical specifications
| Parameter | Specification |
|---|---|
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Structure | Braided multifilament, non-grooved surface |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (metric 3 · EP 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (taperpoint), atraumatic |
| Needle configuration and size | Double needle 2xHR26, 26 mm |
| Thread colour | Green |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Prime (Premisut range) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Factory reference | P853HR2620-2 |
| SKU Cahnos | AMP853HR2620-2 |
Equivalences and cross-references
Reference P853HR2620-2 is the official factory code for this same product; AMP853HR2620-2 is the Cahnos distribution reference. The cross-references with other brands are listed below, classified according to their actual level of equivalence:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polyester 1/2 cylindrical double needle 2xHR26, 2/0, green, 90 cm | P853HR2620-2 / AMP853HR2620-2 | Reference analysed / direct equivalent | Same family, measurements and material; P853HR2620-2 is the official factory code of the product described. |
| B. Braun | PremiCron (braided polyester coated with silicone) 2/0 EP 3, 90 cm, double needle 2xHR26, green | C0026816 | Comparable by category, not interchangeable 1:1 | Same EP 3 gauge, green 90 cm suture, double 26 mm needle with cylindrical-conical point and silicone coating. Verify standards, availability and exact geometry in the official catalogue. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (braided polyester coated with polybutylate) USP 2/0, 90 cm, double 26 mm 1/2 circle needle, green | X966H | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; the coating differs (polybutylate versus silicone). Confirm the actual point and gauge before substituting. |
Important note: there is no equivalence table validated by the manufacturer cross-referencing the Premisut reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or reference substitution.
Selection tips and variants of interest
- USP 2/0 gauge: balanced option for soft tissues, ligatures, ophthalmology and neurosurgery; the double needle facilitates continuous sutures without needle exchange.
- Same HR26 needle, other gauges: single HR26 needle in 3/0 (AMP852HR2630) or 4/0 (AMP852HR2640), or double needle 2xHR26 in 3/0 with 100 cm suture (P857HR2630-2).
- Smaller radius: double needle 2xHR20 in 2/0 and 75 cm (AMP852HR2020-2) for smaller working fields.
- Trocar point with reinforcement: for friable tissues or where tension distribution is required, consider the 2xHRT26 version with a support reinforcement of 6x3x1.5 mm (AMP853HRT2620PL6-2).
- Verification before brand substitution: always check needle angle (1/2), size (26 mm), point type (conical), double needle configuration, USP/EP gauge, exact suture material and coating in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide; respect the storage conditions and the expiry date of the packaging.





Reviews