Description
1. Product Presentation
The polyester suture Premisut Prime with double ½-circle 20 mm needle is the reference choice for professionals seeking a non-absorbable thread with a soft feel, high tensile strength and minimal tissue drag. Its double-needle configuration (2xHR20) with taperpoint conical tip makes it especially suitable for approximating soft tissues, ligatures, ophthalmology and neurosurgery, where every pass must be clean, atraumatic and perfectly controlled. It is supplied sterile, ready to use, in a box of 12 units and is designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone (polyester-polyethylene). This coating provides a smooth outer surface that slides gently through tissue, reduces the sawing effect when tying knots and improves handling and knot security.
Being non-absorbable, it does not lose mass or strength through hydrolysis: gradual fibrous encapsulation occurs and the wound retains mechanical support beyond three months. The ½-circle needle allows suturing with controlled rotational movements, and its conical tip (taperpoint) passes through tissue by separating fibres without cutting them. The double-needle configuration (two needles swaged onto the same thread) facilitates continuous suturing and repositioning without re-threading, optimising surgical time in microsurgery. The green colour ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide (EO).
3. Technical Specifications
| Parameter | Specification |
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (optimal sliding and handling) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Gauge | USP 4/0 (metric 1.5 · EP 1.5) |
| Thread length | 75 cm |
| Needle shape | 1/2 circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical, taperpoint (atraumatic) |
| Needle configuration and size | Double needle 2xHR20, 20 mm |
| Thread colour | Green (non-grooved) |
| Surface | Non-grooved (smooth) |
| Sterilisation | Ethylene oxide (EO), sterile |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units; minimum order of 30 boxes |
| Factory reference | P852HR2040-2 (Prime range) |
| SKU Cahnos | AMP852HR2040-2 |
4. Equivalences and Cross-References
The reference P852HR2040-2 is the official factory code for this same product; AMP852HR2040-2 is the Cahnos distribution reference. There is no manufacturer-validated equivalence table that cross-references this exact configuration (double needle 2xHR20 with conical tip + gauge 4/0 + 75 cm + green) with other brands; the following cross-references are functional category comparisons and must not be considered 1:1 interchangeable without prior technical verification:
| Manufacturer / Brand | Family / Model | Indicative code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polyester 1/2 cylindrical double needle 2xHR20, 4/0, green, 75 cm | P852HR2040-2 / AMP852HR2040-2 | Reference analysed / direct equivalent | Same family, measurements and material; P852HR2040-2 is the official factory code for the described product. |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL® (braided polyester coated with polybutylate), 4/0, 75 cm, green, double needle | X6761G; X551H (double needle RB-1) | Comparable at category level, not interchangeable 1:1 | Same base material and use in soft/ophthalmic tissue; the coating differs (polybutylate vs. silicone) and the exact needle size. Verify radius, tip and gauge in the official catalogue. |
| B. Braun | PremiCron® (braided polyester coated with silicone), 4/0 EP 1.5, 75 cm, green | C0026844 (2xHR13); C0026014 (HR26) | Comparable at category level, not interchangeable 1:1 | Same silicone coating and material; the needle geometry changes (13 or 26 mm vs. 20 mm) and the configuration. Confirm availability in the official catalogue. |
| Medtronic (Covidien) | Surgidac™ / Ti-Cron™ (non-absorbable braided polyester) | Consult official catalogue for gauge and needle | Comparable at category level | Same base material and indications; confirm coating and needle geometry by reference. |
| Cahnos – same family Premisut | Premisut Prime polyester, same needle 2xHR20, other gauges | AMP852HR2020-2 (2/0 green 75 cm) | Same family and needle; gauge changes | Same thread, needle and colour; choose gauge according to clinical need. |
| Cahnos – Premisut other geometries | Single needle HR26 and 3/8 circle | AMP852HR2640 (HR26, 4/0); AMP852DR1340-2 (2xDR13, 4/0) | Similar by category | Single needle or 3/8 circle; not 1:1 interchangeable with the double ½-circle 20 mm needle. |
Pending confirmation: for use in tendering or substitution of another manufacturer’s reference, consult the technical department before formalising the change. The third-party codes cited are indicative and must be checked against each manufacturer’s technical data sheet or IFU.
5. Selection tips and variants of interest
- Same needle 2xHR20, other gauge: if you need greater strength, request the USP 2/0 variant (AMP852HR2020-2), green and 75 cm.
- Single needle: for interrupted suturing in delicate planes, consider the HR26 4/0 version (AMP852HR2640) or the HR30 family (AMP852HR3030 in 3/0 and AMP852HR3020 in 2/0).
- 3/8 circle in microsurgery: the double needle 2xDR13 in 4/0 (AMP852DR1340-2) offers a smaller arc for small working fields.
- Verification before substituting brand: always check needle angle (1/2), size (20 mm), tip type (conical), double-needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide; respect storage conditions and the expiry date of the packaging. Being non-absorbable, it does not require replacement due to loss of strength; its removal, if required, is surgical.