Description
1. Commercial Introduction
The non-absorbable polyester suture Premisut Prime in ½ circle configuration, cylindrical body and 17 mm atraumatic conical point (Taperpoint) is the precision reference for surgical departments seeking a high-performance non-absorbable thread with exceptional handling and predictable tissue behaviour. Presented in USP 5/0 gauge, green colour and 60 cm of thread, it allows a unified criterion in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology, neurosurgery and microsurgery.
The Prime finish (Premilloy needle) guarantees a regular surface, smooth passage through tissue, consistent knot run-down and excellent knot retention. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester, PET) fibres braided into a compact multifilament structure and coated with silicone (polyester – polyethylene). This coating improves passage through tissue, facilitates knot run-down, prevents sawing or channelling effects and reduces tissue trauma, without compromising tensile strength.
As a non-absorbable suture, it is not degraded by the body’s enzymatic action: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs. The ½ circle needle allows suturing in wide or reduced surgical fields with controlled rotational movements, while its conical point (Taperpoint) passes through tissue by separating fibres without cutting them, with minimal tissue aggression, making it especially suitable for delicate planes. The green colour (D&C Green No. 6) improves thread visibility over the surgical field.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 5/0 (metric measure EP 1) |
| Thread length | 60 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body and tip | Cylindrical body with conical tip (Taperpoint), atraumatic |
| Needle configuration and size | Single HR17 needle, 17 mm (Premilloy stainless steel) |
| Number of needles | 1 (single needle) |
| Thread colour | Green (D\u0026C Green No. 6); the family also has a white version |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos (SKU) | AMP856HR1750 |
| Factory reference | P856HR1750 (pending confirmation in official catalogue of the Premisut family) |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (USP/EP standard; indicative value) |
4. Equivalences and Cross-References
The non-absorbable braided polyester suture with ½ circle needle and conical point (Taperpoint) is a consolidated category in the European market. Within the same Premisut family, only a colour change maintains the condition of direct equivalent; any variation in gauge, needle or length automatically downgrades to family equivalence. Cross-references with other brands are functional category comparisons and must always be verified against the manufacturer’s technical data sheet or official IFU before substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut (polyester line, standard quality) | Polyester 1/2 conical tip HR17, 5/0 green, 60 cm | 856HR1750 / AM856HR1750 | Configuration equivalence, not 1:1 interchangeable | Identical dimensions, needle, gauge, colour and length; Normal quality instead of Prime. Validate protocol quality requirement. |
| Premisut Prime (polyester line) | Polyester 1/2 conical tip HR17, 3/0 green, 60 cm | P856HR1730 / AMP856HR1730 | Family equivalence, not interchangeable 1:1 | Same HR17 needle, colour and length; thicker USP 3/0 gauge for tissues with greater resistance. |
| Premisut Prime (polyester line) | Polyester 1/2 conical tip 2xHR17, 3/0, 5 green + 5 white, 10×75 cm | P882HR1730.10-2 / AMP882HR1730.10-2 | Family equivalence, not interchangeable 1:1 | Double needle and dual multipack presentation; changes configuration (2 needles), length (75 cm) and colour (green and white). |
| Premisut Prime (polyester line) | Polyester 1/2 conical tip 2xHR17, 2/0 green, 90 cm | AMP853HR1720-2 | Family equivalence, not interchangeable 1:1 | Same needle and tip; differ in gauge (2/0), configuration (double needle) and length (90 cm). |
| Premisut Prime (polyester line) | Polyester 1/2 trocar point 2xHRT17, 5/0 green, 90 cm | AMP853HRT1750-2 | Comparable by category, not interchangeable 1:1 | Changes point type (trocar/TAPERCUT instead of conical/Taperpoint), suitable for denser tissues; same fineness of 5/0 gauge. |
| B. Braun (Aesculap) | PremiCron® / Dagrofil (braided polyester) | Consult official catalogue for gauge and needle | Comparable by category, not interchangeable 1:1 | Same braided polyester structure; PremiCron with similar silicone coating. Verify HR17 needle, 1/2 conical point and USP/EP gauge in official data sheet before substitution. |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL® / Mersilene (braided polyester) | Consult official catalogue for gauge and needle | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; coating differs (polybutylate vs silicone). Confirm actual point, radius and USP/EP gauge. |
| Medtronic (Covidien) | Ti-Cron™ / Surgidac™ (coated braided polyester) | Consult official catalogue for gauge and needle | Comparable by category, not interchangeable 1:1 | Same base material; Ti-Cron with silicone coating similar to Premisut. Confirm needle-thread format and presentation. |
Important note: there is no manufacturer-validated equivalence table cross-referencing this Premisut Prime reference with other brands; cross-references with B. Braun, Ethicon and Medtronic are functional category comparisons pending official confirmation. Consult the Cahnos technical department before use in tenders or reference substitution.
5. Selection tips and variants of interest
- Delicate tissues and reduced fields: the 17 mm conical point (Taperpoint) offers atraumatic penetration by separating fibres without cutting them, ideal for ophthalmology, neurosurgery, soft tissue approximation and ligatures. If the protocol requires denser or fibrous tissues, consider the trocar point from the same family (AMP853HRT1750-2).
- Same needle, alternative gauge: for greater resistance, the USP 3/0 variant with the same HR17 needle (AMP856HR1730) is available, as well as the standard 5/0 version without Prime finish (AM856HR1750).
- Continuous sutures: if a double needle is required for continuous sutures with two hemi-circles, consider the 2xHR17 configuration in 3/0 (AMP882HR1730.10-2) or in 2/0 (AMP853HR1720-2).
- Single-colour or dual protocols: this reference is high-visibility green; for fields with minimal visual interference, the white variant of the family can be considered.
- Centralised purchasing: product available in box of 12 units with minimum order of 30 boxes; consult purchase conditions for hospital volumes with your Cahnos advisor.
- Before switching brand: always check the needle angle (1/2), size (17 mm), point type (conical/Taperpoint), USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide with a 5-year shelf life, single-use and non-resterilizable; respect storage conditions (below 30 °C, protected from humidity and direct sunlight) and the expiry date of the packaging.