Description
The polyester suture Premisut Prime with a double ½-circle needle, cylindrical body and 26 mm taper point is the reference solution for surgical services seeking a high-performance non-absorbable suture with smooth handling and predictable tissue behaviour. Available in USP size 3/0, green and 100 cm of suture, it allows criteria to be unified in specialties as demanding as ophthalmology and neurosurgery, as well as in the approximation and ligation of soft tissues.
It is supplied sterile, ready to use, in a box of 12 units, and is designed for centralised purchasing by the surgical block and for hospital tenders that require traceability and consistent quality in non-absorbable sutures.
Technical explanation
The suture is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot run-down and reduces tissue trauma. As it is non-absorbable, it is not degraded by the body’s enzymatic action: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place.
The ½ circle needle allows suturing in wide spaces with controlled rotational movements, and its taper point (taperpoint) passes through tissue by separating the fibres without cutting them, with minimal tissue trauma. The double needle configuration (2xHR26) allows continuous sutures to be performed with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time. The green colour ensures optimal visibility of the suture on the surgical field. Ethylene oxide sterilisation ensures a product ready for immediate use in critical procedures.
Technical specifications
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Structure | Braided multifilament, non-grooved surface |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 100 cm |
| Colour | Green |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (taperpoint), atraumatic |
| Needle configuration and size | Double needle 2xHR26, 26 mm |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Factory reference | P857HR2630-2 |
| SKU Cahnos | AMP857HR2630-2 |
Size equivalence (USP/EP table)
| USP size | Metric size | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (USP standard; indicative value according to EP) |
Equivalences and cross-references
Non-absorbable braided polyester suture is a well-established category in the European market. The localised cross-references are listed below with their level of equivalence; only the product’s own factory reference is considered a direct equivalent.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polyester 1/2 circle cylindrical taper point, double needle 2xHR26, 3/0, green, 100 cm | P857HR2630-2 / AMP857HR2630-2 | Reference analysed / direct equivalent | Official factory code of the product itself; same family, sizes and material. |
| Premisut Prime (Cahnos) | Polyester 1/2 circle cylindrical taper point, double needle 2xHR26, 2/0, green, 90 cm | AMP853HR2620-2 | Family equivalence, not interchangeable 1:1 | Same needle and geometry; size 2/0 and length 90 cm. |
| Premisut Prime (Cahnos) | Polyester 1/2 circle cylindrical taper point, single needle HR26, 3/0, green, 75 cm | AMP852HR2630 | Family equivalence, not interchangeable 1:1 | Single needle instead of double needle and 75 cm suture. |
| Premisut Prime (Cahnos) | Polyester 1/2 circle cylindrical trocar point, double needle 2xHRT26, 3/0, green, 90 cm | AMP853HRT2630-2 | Family equivalence, not interchangeable 1:1 | The point changes: trocar (tapercut) instead of taper point; 90 cm suture. |
| B. Braun | PremiCron (silicone-coated braided polyester), double needle 2xHR26, green | C0026816 (verified for size 2/0 EP 3) | Comparable by category, not interchangeable 1:1 | Same material and coating; verify size, point and regulation in the official catalogue before substituting. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (braided polyester coated with polybutilate) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Differences in coating and needle geometry; confirm in the official technical data sheet. |
There is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department before use in tenders or reference substitution.
Selection tips and variants of interest
- Double needle for continuous suturing: the 2xHR26 configuration allows continuous sutures and ligatures to be performed with two hemi-arcs without repositioning the needle, reducing operating theatre time.
- Taper point vs. trocar: the taper point (taperpoint) is atraumatic, ideal for soft tissues and parenchymatous organs; when working with dense or fibrous tissues, consider the variant with trocar point 2xHRT26 (AMP853HRT2630-2).
- Alternative sizes: with the same double needle 2xHR26, USP size 2/0 is available in green and 90 cm (AMP853HR2620-2) for thicker tissue planes.
- Lengths: 75 cm suture with single needle HR26 (AMP852HR2630) or 90 cm with trocar point (AMP853HRT2630-2), depending on the technique and the operative field.
- Centralised purchasing: minimum order of 30 boxes with special conditions for framework contracts and public procurement; consult your Cahnos sales advisor.
- Storage: sterile product by ethylene oxide, single-use and not re-sterilisable; respect storage conditions and the expiry date of the packaging.