Description
1. Commercial Introduction
The nylon suture PREMISUT Prime is the reference choice for operating theatres, purchasing departments and tenders seeking a non-absorbable thread with predictable behaviour and a needle capable of penetrating skin and dense tissues with total control. This presentation in USP 5/0 gauge features a ⅜ circle needle with a triangular point of conventional precision cutting (extra cutting) with a square body of 16 mm —XNS 16 Prime profile— on a black monofilament thread of 75 cm: the classic format for skin closure, plastic and cosmetic surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, in a B2B format designed for hospital replenishment, aesthetic surgery clinics and public tenders. It is marketed under the factory reference P642XNS1650 (SKU AMP642XNS1650), maintained without altering characters.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period (in accordance with USP and European Pharmacopoeia gauges) and becomes gradually encapsulated by connective tissue, supporting the wound for more than three months. The XNS 16 Prime needle (⅜ circle, triangular point with conventional precision cutting with long cutting edge and square body) penetrates firm tissues such as skin, mucosa and fibrous planes, cutting the tissue with a clean and controlled path, reducing resistance to passage and trauma, with excellent stability in the needle holder thanks to its square body. The USP 5/0 gauge (metric EP 1) is a fine thread with adequate strength to approximate soft tissues with minimal visible scarring, ideal for aesthetic results. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer / distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Indicative thread diameter | 0.10 – 0.15 mm |
| Thread length | 75 cm (1 suture with 1 needle per unit) |
| Thread colour | Black |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular point, conventional precision cutting (extra cutting), long cutting edge |
| Needle body | Square (maximum stability in the needle holder) |
| Needle size | 16 mm (XNS 16 Prime profile) |
| Number of needles | 1 (single-armed) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P642XNS1650 |
| Reference Cahnos (SKU) | AMP642XNS1650 |
3.2. Family Premisut Prime XNS 16 in nylon (⅜ circle, triangular point, conventional precision cutting)
| Needle profile | USP | Presentation | Reference |
|---|---|---|---|
| XNS 16 Prime | 5/0 | 1 × 75 cm | P642XNS1650 / AMP642XNS1650 (this product) |
3.3. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | EP metric measure | Indicative diameter | Thread length |
|---|---|---|---|
| 5/0 | 1 | 0.10 – 0.15 mm | 75 cm |
4. Equivalences and Cross-References
The reference P642XNS1650 corresponds to the official nomenclature of the Premisut Prime range (XNS 16 Prime profile, ⅜ needle with triangular point of conventional precision cutting, square body of 16 mm, USP 5/0 gauge, black thread of 75 cm). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 5/0 (EP 1), 75 cm, DS16 needle ⅜ circle triangular point reverse cutting of 16 mm | C0935123 (verified in official B. Braun catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match material (polyamide), gauge 5/0, thread diameter, length of 75 cm, ⅜ radius and triangular needle of 16 mm; differences: blue colour versus black and precision sharpening (extra cutting) of the Premisut versus standard reverse cutting; confirm geometry and batch against IFU |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® Precision Cosmetic Conventional Cutting Prime – black nylon monofilament, USP 5/0, 45 cm, PC-1 needle ⅜ circle conventional precision cutting of 13 mm | 1955G (verified in official Ethicon EPC catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | Same material (polyamide 6/6.6), same gauge 5/0, black colour and same family of conventional precision point; differences: needle of 13 mm versus 16 mm and thread of 45 cm versus 75 cm; confirm presentation and size against IFU |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, USP 5/0, 45 cm, PC-3 needle ⅜ circle conventional cutting of 16 mm | 1865G (verified in official Ethicon EPC catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match material, gauge 5/0, black colour and needle size of 16 mm of the same conventional type; difference: thread of 45 cm versus 75 cm; confirm presentation and IFU before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P642XNS1650 with other brands; the comparisons with DAFILON® and ETHILON® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Other homologous families on the market (e.g. Monosof from Covidien/Medtronic) require verification of gauge, length and needle geometry on a case-by-case basis. This needle geometry (XNS 16 Prime, extra cutting with square body) is only interchangeable with full safety within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the XNS needle with triangular point of conventional precision cutting is indicated for skin, mucosa and fibrous planes that require firm penetration with minimal trauma; for soft lax, vascular or well-irrigated tissues, the same Premisut range offers conical point needles (e.g. nylon HR 16 and HR 20). The USP 5/0 gauge is an ideal balance point between fineness and strength for skin closure, plastic surgery and precision procedures.
Gauge and presentation: with the same precision XNS 16 needle, it is available in nylon 5/0, 75 cm, in a 6/0 version (AMP642XNS1660) or 5/0 on a 45 cm thread (AMP641XNS1650). If you prefer a cylindrical needle, the range offers nylon 5/0, 75 cm, with a ½ circle HR 16 needle (AMP642HR1650) or, with a ½ 20 mm needle, the HR20 in gauges 6/0, 5/0, 4/0, 3/0 and 2/0 (AMP642HR2050 and variants). For finer gauges from the same precision XNS family, see the full Premisut Prime range.
Specialties: in ophthalmology and microsurgery, the range offers shorter and finer needle profiles in gauges 10/0 and 11/0 (e.g. DR and DSP needles from the Premisut Prime system); for skin and cosmetic surgery, this XNS 16 presentation in 5/0 is the most requested.
Material alternatives in the same geometry: if the protocol prefers a non-absorbable braided suture with the same XNS 16 needle profile, the range offers Premisut Prime silk in gauges 6/0, 5/0 and 4/0 (e.g. AMP541XNS1650). Unifying the supplier across the entire suture portfolio enables B2B volume conditions.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P642XNS1650 and the batch number for traceability in the operating theatre and in the event of a claim. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.