Description
1. Product Presentation
We place at your disposal the non-absorbable monofilament nylon suture from the PREMISUT Prime range, reference AMP642RDS6020, a professional solution for B2B supply to operating theatres, purchasing centres, general and specialist surgery departments, as well as ophthalmology and neurosurgery units.
This presentation incorporates a ⅜ circle reverse cutting needle of 60 mm (DS60) with 2 black strands of 75 cm in USP 2/0 gauge; one of the most in-demand configurations for precision suturing on soft tissues, ligatures and deep access planes. Predictable performance, high tensile strength and special conditions for hospital supply and volume contracts.
2. Technical explanation of the material and procedure
The suture is manufactured in nylon (polyamide 6 or 6.6) in monofilament configuration: a single continuous, smooth and uncoated filament, which minimises microorganism adherence, the sawing effect on tissue and the inflammatory reaction. Being non-absorbable, it permanently maintains its structural integrity and provides gradual encapsulation with great tensile strength, helping to support the wound for more than three months. The strand diameter in USP 2/0 gauge is between 0.30 and 0.339 mm according to the USP Pharmacopoeia for non-absorbable sutures.
The ⅜ circle needle with triangular body and 60 mm reverse cutting point allows precise, minimally traumatic penetration in tissues with some resistance, ideal for stitches in closed planes, dermis, subcutaneous tissue and precision approximations in ophthalmology and neurosurgery. The black colour guarantees optimal contrast on the surgical field. The 2×75 cm presentation incorporates two strands per unit, practical for continuous or multi-point suture techniques. Ethylene oxide sterilisation ensures its sterile delivery, ready for immediate use; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP642RDS6020 |
| Brand / Quality | PREMISUT Prime |
| Material | Nylon (polyamide 6 / 6.6), synthetic monofilament |
| Thread structure | Monofilament, uncoated |
| Gauge / USP size | USP 2/0 (metric 3 / EP 3) |
| Strand diameter | 0.30 – 0.339 mm (non-absorbable suture, according to USP Pharmacopoeia) |
| Thread presentation | 2 threads of 75 cm (2×75 cm) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8) |
| Tip type | Triangular reverse cutting (Reverse Cutting), triangular body and point, fluted |
| Needle size | 60 mm (DS 60 Prime model) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units |
Gauge equivalence (non-absorbable suture, according to USP Pharmacopeia):
| USP size | Metric measurement (EP) | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
Minimal tissue reaction, excellent tensile strength, secure knot and fully predictable behaviour as there is no polymer degradation in the body. The thread diameter complies with the USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its official limits.
4. Equivalences and Cross-References
Non-absorbable monofilament nylon is one of the most widespread permanent suture families in the surgical market for soft tissue approximation and ligatures. There is no manufacturer-validated equivalence table cross-referencing this specific configuration (3/8 circle reverse cutting needle DS60 mm, USP 2/0 gauge, black, 2×75 cm) with references from other manufacturers; therefore, the following matches must be treated as functional comparisons and not as 1:1 interchangeable without technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | Dafilon | B0935905 (USP 2/0 [EP 3], blue, 100 cm, DS60 3/8 circle reverse cutting needle) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official B. Braun catalogue. It matches in material (polyamide 6/6.6), USP 2/0 gauge, 3/8 circle curvature, reverse cutting point family and DS60 needle size of 60 mm; the strand colour (blue versus black) and the presentation (1×100 cm versus 2×75 cm) differ. |
Partially verified homologous families, excluded from the table as they do not meet all matching criteria:
- Ethicon (Johnson & Johnson) – ETHILON: polyamide 6/6.6 monofilament, black dye; ref. 628H (USP 2/0, black, 75 cm) is confirmed but mounts a KS straight needle of 60 mm, so the curvature differs (straight versus 3/8 circle).
- Atramat – Nylon monofilament: ref. PE2642-75N (USP 2/0, black, 75 cm, PE-26 3/8 circle reverse cutting needle) is confirmed in authorised distributors, but the needle size is 26 mm versus the 60 mm of this reference.
- B. Braun – Dafilon ref. C0935379 (USP 0, 75 cm, DS24 needle): same family, but gauge and needle size differ; not 1:1 interchangeable.
- Medtronic/Covidien – Monosof / Dermalon and Serag-Wiessner – SERALON: black monofilament nylon with GUDID/FDA registrations; check needle nomenclature, size and regulatory traceability (CE/MDR) of the batch before any substitution.
Closing phrase: There is no manufacturer-validated equivalence table for this configuration; consult the technical-commercial department of Cahnos before use in tenders. Before any formal substitution, verify in the alternative manufacturer’s technical data sheet the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Assess the wound support time required by the tissue and the gauge according to the anatomical area: USP 2/0 gauge (metric 3) is very versatile, indicated for skin, subcutaneous tissue and soft tissues with moderate tension, as well as for precision approximation in ophthalmology and neurosurgery. Always check the needle geometry: the 3/8 circle DS series with reverse cutting is intended for deep sutures, closed planes and tissues with some resistance. The 2×75 cm presentation is especially practical for continuous, multi-point suture techniques or high-volume services, as it incorporates two strands per unit.
Variants of interest within the Cahnos catalogue:
- AMP642DS6020: same DS60 Prime needle and 2/0 gauge, black, single thread of 75 cm.
- AMP647RDS6020: same DS60 Prime needle and 2/0 gauge, black, 2×100 cm presentation.
- AMP642RDS6010: same DS60 Prime needle, USP 0 gauge, black, 2×75 cm (larger gauge).
- AMP643DS4020: DS40 mm needle, USP 2/0, black, 90 cm (more superficial planes).
- AMP642GS6020: nylon PREMISUT Prime with GS60 mm straight needle for direct access.
- AMP542DS6020: PREMISUT Prime braided silk with the same DS60 needle, to alternate material according to surgeon preference.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.